Mostrar el registro sencillo del ítem
dc.contributor.author | Torres, J. | es_ES |
dc.contributor.author | Aguilar, A. | es_ES |
dc.contributor.author | Garcia-Olcina, R. | es_ES |
dc.contributor.author | Martinez, P.A. | es_ES |
dc.contributor.author | Martos, J. | es_ES |
dc.contributor.author | Soret, J. | es_ES |
dc.contributor.author | Benlloch Baviera, Jose María | es_ES |
dc.contributor.author | Conde Castellanos, Pablo Eloy | es_ES |
dc.contributor.author | González Martínez, Antonio Javier | es_ES |
dc.contributor.author | Sanchez, F. | es_ES |
dc.date.accessioned | 2017-06-29T08:39:23Z | |
dc.date.available | 2017-06-29T08:39:23Z | |
dc.date.issued | 2014-02 | |
dc.identifier.issn | 0018-9499 | |
dc.identifier.uri | http://hdl.handle.net/10251/84096 | |
dc.description.abstract | [EN] This contribution describes an accurate approach implementing a Time-to-Digital Converter using a Field-Programmable Gate Array (FPGA) device. Time differences with a FWHM better than 100 ps for 24 pairs of channels working simultaneously have been achieved. This was possible through the proper management of FPGA internal resources and by an accurate device calibration process minimizing the effect of temperature and voltage fluctuations. The system calibration results and the time differences between multiple channels are presented. The current approach suggests the possibility of carrying out precise Time of Flight (TOF) measurements with, for instance, Positron Emission Tomography (PET) systems. | es_ES |
dc.description.sponsorship | This work was supported in part by the University of Valencia. | |
dc.language | Inglés | es_ES |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | es_ES |
dc.relation.ispartof | IEEE Transactions on Nuclear Science | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Delay lines | es_ES |
dc.subject | Field programmable gate arrays | es_ES |
dc.subject | Positron emission tomography | es_ES |
dc.subject | Time measurement | es_ES |
dc.title | Time-to-Digital Converter Based on FPGA With Multiple Channel Capability | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1109/TNS.2013.2283196 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.description.bibliographicCitation | Torres, J.; Aguilar, A.; Garcia-Olcina, R.; Martinez, P.; Martos, J.; Soret, J.; Benlloch Baviera, JM.... (2014). Time-to-Digital Converter Based on FPGA With Multiple Channel Capability. IEEE Transactions on Nuclear Science. 61(1):107-114. https://doi.org/10.1109/TNS.2013.2283196 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1109/TNS.2013.2283196 | es_ES |
dc.description.upvformatpinicio | 107 | es_ES |
dc.description.upvformatpfin | 114 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 61 | es_ES |
dc.description.issue | 1 | es_ES |
dc.relation.senia | 258711 | es_ES |
dc.contributor.funder | Universitat de València |