Anomalous effects on radiation detectors and capacitance measurements inside a modified Faraday cage

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Anomalous effects on radiation detectors and capacitance measurements inside a modified Faraday cage

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Milián Sánchez, Víctor Miguel es_ES
dc.contributor.author Mocholí Salcedo, Antonio es_ES
dc.contributor.author Milian, Carlos es_ES
dc.contributor.author Kolombet, V.A. es_ES
dc.contributor.author Verdú Martín, Gumersindo Jesús es_ES
dc.date.accessioned 2017-07-04T11:39:27Z
dc.date.available 2017-07-04T11:39:27Z
dc.date.issued 2016-08-21
dc.identifier.issn 0168-9002
dc.identifier.uri http://hdl.handle.net/10251/84418
dc.description.abstract We present experimental results showing certain anomalies in the measurements performed inside a modified Faraday cage of decay rates of Ra-226, Tl-204 and Sr-90/I-90, of the gamma spectrum of a Cs-137 preparation, and of the capacitance of both a class-I multilayer ceramic capacitor and of the interconnection cable between the radiation detector and the scaler. Decay rates fluctuate significantly up to 5% around the initial value and differently depending on the type of nuclide, and the spectrum photopeak increases in 4.4%. In the case of the capacitor, direct capacitance measurements at 100 Hz, 10 kHz and 100 kHz show variations up to 0.7%, the most significant taking place at 100 Hz. In the case of the interconnection cable, the capacitance varies up to 1%. Dispersion also tends to increase inside the enclosure. However, the measured capacitance variations do not explain the variations observed in decay rates. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Capacitance variability es_ES
dc.subject Decay rates variability es_ES
dc.subject Modified Faraday cage es_ES
dc.subject Multichannel analyzer es_ES
dc.subject Multilayer ceramic capacitor es_ES
dc.subject Nuclide es_ES
dc.subject.classification INGENIERIA NUCLEAR es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Anomalous effects on radiation detectors and capacitance measurements inside a modified Faraday cage es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.nima.2016.05.051
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Seguridad Industrial, Radiofísica y Medioambiental - Institut de Seguretat Industrial, Radiofísica i Mediambiental es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Telecomunicación - Escola Tècnica Superior d'Enginyers de Telecomunicació es_ES
dc.description.bibliographicCitation Milián Sánchez, VM.; Mocholí Salcedo, A.; Milian, C.; Kolombet, V.; Verdú Martín, GJ. (2016). Anomalous effects on radiation detectors and capacitance measurements inside a modified Faraday cage. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 828:210-228. doi:10.1016/j.nima.2016.05.051 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.nima.2016.05.051 es_ES
dc.description.upvformatpinicio 210 es_ES
dc.description.upvformatpfin 228 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 828 es_ES
dc.relation.senia 313125 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem