Mostrar el registro sencillo del ítem
dc.contributor.author | Milián Sánchez, Víctor Miguel | es_ES |
dc.contributor.author | Mocholí Salcedo, Antonio | es_ES |
dc.contributor.author | Milian, Carlos | es_ES |
dc.contributor.author | Kolombet, V.A. | es_ES |
dc.contributor.author | Verdú Martín, Gumersindo Jesús | es_ES |
dc.date.accessioned | 2017-07-04T11:39:27Z | |
dc.date.available | 2017-07-04T11:39:27Z | |
dc.date.issued | 2016-08-21 | |
dc.identifier.issn | 0168-9002 | |
dc.identifier.uri | http://hdl.handle.net/10251/84418 | |
dc.description.abstract | We present experimental results showing certain anomalies in the measurements performed inside a modified Faraday cage of decay rates of Ra-226, Tl-204 and Sr-90/I-90, of the gamma spectrum of a Cs-137 preparation, and of the capacitance of both a class-I multilayer ceramic capacitor and of the interconnection cable between the radiation detector and the scaler. Decay rates fluctuate significantly up to 5% around the initial value and differently depending on the type of nuclide, and the spectrum photopeak increases in 4.4%. In the case of the capacitor, direct capacitance measurements at 100 Hz, 10 kHz and 100 kHz show variations up to 0.7%, the most significant taking place at 100 Hz. In the case of the interconnection cable, the capacitance varies up to 1%. Dispersion also tends to increase inside the enclosure. However, the measured capacitance variations do not explain the variations observed in decay rates. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Capacitance variability | es_ES |
dc.subject | Decay rates variability | es_ES |
dc.subject | Modified Faraday cage | es_ES |
dc.subject | Multichannel analyzer | es_ES |
dc.subject | Multilayer ceramic capacitor | es_ES |
dc.subject | Nuclide | es_ES |
dc.subject.classification | INGENIERIA NUCLEAR | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Anomalous effects on radiation detectors and capacitance measurements inside a modified Faraday cage | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.nima.2016.05.051 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Seguridad Industrial, Radiofísica y Medioambiental - Institut de Seguretat Industrial, Radiofísica i Mediambiental | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Telecomunicación - Escola Tècnica Superior d'Enginyers de Telecomunicació | es_ES |
dc.description.bibliographicCitation | Milián Sánchez, VM.; Mocholí Salcedo, A.; Milian, C.; Kolombet, V.; Verdú Martín, GJ. (2016). Anomalous effects on radiation detectors and capacitance measurements inside a modified Faraday cage. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 828:210-228. doi:10.1016/j.nima.2016.05.051 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.nima.2016.05.051 | es_ES |
dc.description.upvformatpinicio | 210 | es_ES |
dc.description.upvformatpfin | 228 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 828 | es_ES |
dc.relation.senia | 313125 | es_ES |