- -

Initial performance evaluation of a high resolution Albira small animal positron emission tomography scanner with monolithic crystals and depth-of-interaction encoding from a user's perspective

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Initial performance evaluation of a high resolution Albira small animal positron emission tomography scanner with monolithic crystals and depth-of-interaction encoding from a user's perspective

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Balcerzyk, Marcin es_ES
dc.contributor.author Kontaxakis, George es_ES
dc.contributor.author Delgado, Mercedes es_ES
dc.contributor.author Garcia-Garcia, Luis es_ES
dc.contributor.author Correcher Salvador, Carlos es_ES
dc.contributor.author González Martínez, Antonio Javier es_ES
dc.contributor.author Gonzalez, Aurora es_ES
dc.contributor.author Rubio, Jose L. es_ES
dc.contributor.author Benlloch Baviera, Jose María es_ES
dc.contributor.author Pozo, Miguel A. es_ES
dc.date.accessioned 2017-07-07T08:47:29Z
dc.date.available 2017-07-07T08:47:29Z
dc.date.issued 2009-10
dc.identifier.issn 0957-0233
dc.identifier.uri http://hdl.handle.net/10251/84692
dc.description.abstract The user evaluation of the Albira small animal positron emission tomography scanner is presented. The system has a circle divide 80 mm x 40 mm field of view. In the center of the field of view, it has 2.49% sensitivity, with 33% solid angle coverage, and 0.88% sensitivity for a mouse phantom. The maximum of noise equivalent counts is 14.6 kcps at 6.0 MBq for a mouse phantom. The scanner employs an innovative crystal design of eight 40(50) x 40(50) x 9.8 mm(3) LYSO tapered monolithic crystals forming detector modules read by position-sensitive photomultipliers. This design allows for easy depth-of-interaction readout. The system saturates at 6.7 MBq for the mouse phantom. As an example of the application of the Albira system, some preliminary results from a study of ischemic stroke on animal models with 18-FDG co-registered with MRI images are shown es_ES
dc.description.sponsorship The study was supported in part by the MULTIMAG (S-BIO-0170-2006) project of Comunidad de Madrid, Spain, and FPA2007-65013-C02-01 project. MB was supported by Marie-Curie fellowship project no MEIF-CT-2006-041482 from European Commission. JLR is grateful for the support by Fellowship FPI (BES-2005-8126), Ministerio de Educacion y Ciencia de Espana. en_EN
dc.language Inglés es_ES
dc.publisher IOP Publishing es_ES
dc.relation.ispartof Measurement Science and Technology es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Small-animal PET es_ES
dc.subject Performance measurements es_ES
dc.subject Instrumentation es_ES
dc.subject Small-animal imaging es_ES
dc.subject Ischemia es_ES
dc.title Initial performance evaluation of a high resolution Albira small animal positron emission tomography scanner with monolithic crystals and depth-of-interaction encoding from a user's perspective es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1088/0957-0233/20/10/104011
dc.relation.projectID info:eu-repo/grantAgreement/CAM//S-BIO-0170-2006/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MEC//-2006-0414/ES/-2006-0414/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MEC//BES-2005-8126/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MEC//FPA2007-65013-C02-01/ES/DESARROLLO DE UN NUEVO SENSOR DE RAYOS GAMMA PARA DIAGNOSTICO DE ENFERMEDADES NEUROLOGICAS/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario Mixto de Biología Molecular y Celular de Plantas - Institut Universitari Mixt de Biologia Molecular i Cel·lular de Plantes es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular es_ES
dc.description.bibliographicCitation Balcerzyk, M.; Kontaxakis, G.; Delgado, M.; Garcia-Garcia, L.; Correcher Salvador, C.; González Martínez, AJ.; Gonzalez, A.... (2009). Initial performance evaluation of a high resolution Albira small animal positron emission tomography scanner with monolithic crystals and depth-of-interaction encoding from a user's perspective. Measurement Science and Technology. 20(10):104011-1-104011-6. https://doi.org/10.1088/0957-0233/20/10/104011 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1088/0957-0233/20/10/104011 es_ES
dc.description.upvformatpinicio 104011-1 es_ES
dc.description.upvformatpfin 104011-6 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 20 es_ES
dc.description.issue 10 es_ES
dc.relation.senia 206083 es_ES
dc.contributor.funder Ministerio de Educación y Ciencia es_ES
dc.contributor.funder Comunidad de Madrid es_ES
dc.description.references Tai, Y.-C., Chatziioannou, A. F., Yang, Y., Silverman, R. W., Meadors, K., Siegel, S., … Cherry, S. R. (2003). MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging. Physics in Medicine and Biology, 48(11), 1519-1537. doi:10.1088/0031-9155/48/11/303 es_ES
dc.description.references Huisman, M. C., Reder, S., Weber, A. W., Ziegler, S. I., & Schwaiger, M. (2006). Performance evaluation of the Philips MOSAIC small animal PET scanner. European Journal of Nuclear Medicine and Molecular Imaging, 34(4), 532-540. doi:10.1007/s00259-006-0271-7 es_ES
dc.description.references Kim, J. S., Lee, J. S., Im, K. C., Kim, S. J., Kim, S.-Y., Lee, D. S., & Moon, D. H. (2007). Performance Measurement of the microPET Focus 120 Scanner. Journal of Nuclear Medicine, 48(9), 1527-1535. doi:10.2967/jnumed.107.040550 es_ES
dc.description.references Visser, E. P., Disselhorst, J. A., Brom, M., Laverman, P., Gotthardt, M., Oyen, W. J. G., & Boerman, O. C. (2008). Spatial Resolution and Sensitivity of the Inveon Small-Animal PET Scanner. Journal of Nuclear Medicine, 50(1), 139-147. doi:10.2967/jnumed.108.055152 es_ES
dc.description.references Jan, S., Santin, G., Strul, D., Staelens, S., Assié, K., Autret, D., … Bloomfield, P. M. (2004). GATE: a simulation toolkit for PET and SPECT. Physics in Medicine and Biology, 49(19), 4543-4561. doi:10.1088/0031-9155/49/19/007 es_ES
dc.description.references Lerche, C. W., Benlloch, J. M., Sánchez, F., Pavón, N., Giménez, N., Fernández, M., … Mora, F. J. (2005). Depth of interaction detection with enhanced position-sensitive proportional resistor network. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 537(1-2), 326-330. doi:10.1016/j.nima.2004.08.036 es_ES
dc.description.references Ling, T., Lee, K., & Miyaoka, R. S. (2006). Performance Comparisons of Continuous Miniature Crystal Element (cMiCE) Detectors. IEEE Transactions on Nuclear Science, 53(5), 2513-2518. doi:10.1109/tns.2006.882296 es_ES
dc.description.references Maas, M. C., Schaart, D. R., van der Laan, D. J. (Jan), Bruyndonckx, P., Lemaître, C., Beekman, F. J., & van Eijk, C. W. E. (2009). Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction. Physics in Medicine and Biology, 54(7), 1893-1908. doi:10.1088/0031-9155/54/7/003 es_ES
dc.description.references Shepp, L. A., & Vardi, Y. (1982). Maximum Likelihood Reconstruction for Emission Tomography. IEEE Transactions on Medical Imaging, 1(2), 113-122. doi:10.1109/tmi.1982.4307558 es_ES
dc.description.references Hudson, H. M., & Larkin, R. S. (1994). Accelerated image reconstruction using ordered subsets of projection data. IEEE Transactions on Medical Imaging, 13(4), 601-609. doi:10.1109/42.363108 es_ES
dc.description.references Grootoonk, S., Spinks, T. J., Sashin, D., Spyrou, N. M., & Jones, T. (1996). Correction for scatter in 3D brain PET using a dual energy window method. Physics in Medicine and Biology, 41(12), 2757-2774. doi:10.1088/0031-9155/41/12/013 es_ES
dc.description.references Badawi, R. D., Miller, M. P., Bailey, D. L., & Marsden, P. K. (1999). Randoms variance reduction in 3D PET. Physics in Medicine and Biology, 44(4), 941-954. doi:10.1088/0031-9155/44/4/010 es_ES
dc.description.references Astrup, J., Siesjö, B. K., & Symon, L. (1981). Thresholds in cerebral ischemia - the ischemic penumbra. Stroke, 12(6), 723-725. doi:10.1161/01.str.12.6.723 es_ES
dc.description.references HURTADO, O., DE CRISTÓBAL, J., SÁNCHEZ, V., LIZASOAIN, I., CÁRDENAS, A., PEREIRA, M. P., … MORO, M. A. (2003). Inhibition of glutamate release by delaying ATP fall accounts for neuroprotective effects of antioxidants in experimental stroke. The FASEB Journal, 17(14), 2082-2084. doi:10.1096/fj.02-1086fje es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem