dc.description.abstract | The goal of this project, is to study the thermal loads of the building of the auditorium and rectory of the Universitat Politècnica de València to get the peak power consumption of his heating and cooling facilities. Next, based on the results gathered from the energy simulation in the building in the representative days of winter and summer we will procceed to propose passive energy saving measures to reduce the maximum power consumption with an study associated to each one of them to assess the profitabilty of their enforcement. To make this project, it we had used the energetic simulation in buildings software Design Builder. With this tool, we model the building using their prints, ocuppancy and activity data, the composition of the walls, roofs, ceilings and glazing, the lightning instalation of the building and other power consuming equipment. | es_ES |
dc.description.abstract | La finalidad del proyecto realizado es el estudio de las cargas térmicas presentes en el edificio del paraninfo y rectorado de la Universidad Politécnica de Valencia con el fin de obtener la demandas energéticas pico de calefacción y refrigeración en este. Acto seguido, en función de los resultados obtenidos en la simulación energética del edificio en los días representativos para verano e invierno se dispondrá a proponer medidas pasivas para la reducción de la potencia consumida con un estudio asociado a cada una de ellas para poder evaluar la rentabilidad de su aplicación. Para la realización de este proyecto se ha empleado la herramienta de simulación energética en edificios Design Builder. En esta se modela el edificio objeto a partir de sus planos, los datos de ocupación y actividad, la composición de los muros, techos y ventanas de este además de la iluminación y presencia de otros elementos consumidores de energía. | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Energy simulation | es_ES |
dc.subject | calculation of heat loads | es_ES |
dc.subject | therm-economic analysis | es_ES |
dc.subject | energy efficiency in buildings | es_ES |
dc.subject | Simulación energética | es_ES |
dc.subject | cálculo de cargas | es_ES |
dc.subject | análisis termoeconómico | es_ES |
dc.subject | eficiencia energética en edificios | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.subject.other | Grado en Ingeniería de la Energía-Grau en Enginyeria de l'Energia | es_ES |
dc.title | Análisis de soluciones pasivas para la reducción de la demanda energética máxima en el paraninfo de la Universitat Politècnica de València | es_ES |
dc.type | Proyecto/Trabajo fin de carrera/grado | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada | es_ES |
dc.description.bibliographicCitation | Beato Pérez, M. (2017). Análisis de soluciones pasivas para la reducción de la demanda energética máxima en el paraninfo de la Universitat Politècnica de València. http://hdl.handle.net/10251/87155. | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\71972 | es_ES |