- -

Computer modelling of RF ablation in cortical osteoid osteoma: Assessment of the insulating effect of the reactive zone

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Computer modelling of RF ablation in cortical osteoid osteoma: Assessment of the insulating effect of the reactive zone

Mostrar el registro completo del ítem

Irastorza, RM.; Trujillo Guillen, M.; Martel Villagran, J.; Berjano, E. (2016). Computer modelling of RF ablation in cortical osteoid osteoma: Assessment of the insulating effect of the reactive zone. International Journal of Hyperthermia. 32(3):221-230. https://doi.org/10.3109/02656736.2015.1135998

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/89273

Ficheros en el ítem

Metadatos del ítem

Título: Computer modelling of RF ablation in cortical osteoid osteoma: Assessment of the insulating effect of the reactive zone
Autor: Irastorza, Ramiro M. Trujillo Guillen, Macarena Martel Villagran, Jose Berjano, Enrique
Entidad UPV: Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny
Universitat Politècnica de València. Escuela Técnica Superior de Arquitectura - Escola Tècnica Superior d'Arquitectura
Fecha difusión:
Resumen:
Purpose: The aim was to study by computer simulations the insulating role of the reactive zone surrounding a cortical osteoid osteoma (OO) in terms of electrical and thermal performance during radiofrequency ablation ...[+]
Palabras clave: Computer modeling , Cortical bone , Finite element method , Osteoid osteoma , Radiofrequency ablation , Reactive zone
Derechos de uso: Reserva de todos los derechos
Fuente:
International Journal of Hyperthermia. (issn: 0265-6736 )
DOI: 10.3109/02656736.2015.1135998
Editorial:
Taylor & Francis
Versión del editor: http://dx.doi.org/10.3109/02656736.2015.1135998
Código del Proyecto:
info:eu-repo/grantAgreement/ANPCyT//PICT-2012-1201/AR/Simulación y evaluación de propiedades dieléctricas de tejidos óseos/
info:eu-repo/grantAgreement/MINECO//TEC2014-52383-C3-1-R/ES/TECNOLOGIAS BASADAS EN ENERGIA DE RADIOFRECUENCIA Y MICROONDAS PARA CIRUGIA DE MINIMA INVASION/
Descripción: This is an Accepted Manuscript of an article published by Taylor & Francis in International Journal of Hyperthermia on 10 Feb 2016, available online: http://www.tandfonline.com/10.3109/02656736.2015.1135998
Agradecimientos:
This work was supported by a grant from the Agencia Nacional de Promocion Cientifica y Tecnologica de Argentina (Ref. PICT-2012-1201), and by the Spanish Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada ...[+]
Tipo: Artículo

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem