Mostrar el registro sencillo del ítem
dc.contributor.author | Carles, M. | es_ES |
dc.contributor.author | Lerche, Christoph Werner | es_ES |
dc.contributor.author | Sánchez Martínez, Filomeno | es_ES |
dc.contributor.author | Mora Mas, Francisco José | |
dc.contributor.author | Benlloch Baviera, Jose María | |
dc.date.accessioned | 2017-12-21T12:54:46Z | |
dc.date.available | 2017-12-21T12:54:46Z | |
dc.date.issued | 2011 | es_ES |
dc.identifier.issn | 0168-9002 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/93281 | |
dc.description.abstract | [EN] In this work we study the effects on the spatial resolution when depth of interaction (001) information is included in the parameterization of the line of response (LOR) for a small animal positron emission tomography (PET) system. One of the most important degrading factors for PET is the parallax error introduced in systems that do not provide DOI information of the recorded gamma-rays. Our group has designed a simple and inexpensive method for DOI determination in continuous scintillation crystals. This method is based, on one hand, in the correlation between the scintillation light distribution width in monolithic crystals and the DOI, and, on the other hand, on a small modification of the widely applied charge dividing circuits (CDR). In this work we present a new system calibration that includes the DOI information, and also the development of the correction equations that relates the LOR without and with DOI information. We report the results obtained for different measurements along the transaxial field of view (FOV) and the image quality enhancement achieved specially at the edge of the FOV. (C) 2010 Elsevier B.V. All rights reserved. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | DOI | es_ES |
dc.subject | PET | es_ES |
dc.subject | Positioning algorithm | es_ES |
dc.subject | Gamma ray imaging | es_ES |
dc.subject | Continuous scintillators | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Position correction with depth of interaction information for a small animal PET system | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.nima.2010.11.192 | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario Mixto de Biología Molecular y Celular de Plantas - Institut Universitari Mixt de Biologia Molecular i Cel·lular de Plantes | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Carles, M.; Lerche, CW.; Sánchez Martínez, F.; Mora Mas, FJ.; Benlloch Baviera, JM. (2011). Position correction with depth of interaction information for a small animal PET system. Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment. 648:176-180. doi:10.1016/j.nima.2010.11.192 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.nima.2010.11.192 | es_ES |
dc.description.upvformatpinicio | 176 | es_ES |
dc.description.upvformatpfin | 180 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 648 | es_ES |
dc.relation.pasarela | S\216952 | es_ES |