Mixed model for the analytical determination of critical buckling load of passive reinforcement in compressed RC and FRC elements under monotonic loading

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Mixed model for the analytical determination of critical buckling load of passive reinforcement in compressed RC and FRC elements under monotonic loading

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Pereiro Barceló, Javier es_ES
dc.contributor.author Bonet Senach, José Luís es_ES
dc.date.accessioned 2017-12-21T12:56:04Z
dc.date.available 2017-12-21T12:56:04Z
dc.date.issued 2017 es_ES
dc.identifier.issn 0141-0296 es_ES
dc.identifier.uri http://hdl.handle.net/10251/93282
dc.description.abstract [EN] Compressed reinforcements on reinforced concrete (RC) and steel fibre reinforced concrete (SFRC) columns are generally submitted to cyclic and monotonic loading, which can buckle. This phenomenon can cause the reduction of both ductility and peak loads, which is why design standards propose constructive details to avoid this. Although the bibliography mentions that steel fibres in concrete can delay buckling of reinforcements, design codes do not distinguish between concrete types (with and without fibres) in these constructive details. Analytical models that determine the length and critical buckling stress of reinforcements may consider this effect. Nowadays, analytical models can be classified as discrete and distributed depending on whether they consider transverse reinforcement stiffness and the stiffness of the concrete cover that concentrates on transverse reinforcements, or if they are distributed along the element, respectively. Both discrete and distributed models are valid for small transverse reinforcement separations, while distributed models that only consider the concrete cover effect are valid for large transverse reinforcement separations. This paper proposes a mixed model to determine critical buckling loads of compressed reinforcements subjected to monotonic loading to use the stress-strain relationships of reinforcing bars, including buckling, that are found in the scientific-technical literature. This model considers transverse reinforcements discretely and concrete cover distributedly. The model can be applied to any transverse reinforcement configuration, and to any concrete type (with or without fibres). An analytical equation is also proposed to determine critical compressed reinforcement loads, whose result is presented as abaci. Finally, to calibrate the model in normal-strength concrete columns under eccentric loading, with or without fibres, a programme is presented in which the critical load of longitudinal reinforcements is experimentally determined. The proposed analytical model is calibrated and a procedure to determine critical buckling loads of compressed reinforcements under monotonic loading is proposed. es_ES
dc.description.sponsorship The model presented herein forms part of a research line that is being undertaken at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politècnica de València (UPV). The authors are sincerely grateful to the Spanish Ministry of Economy and Competitiveness for the help it has provided through Project BIA2012-32645 and to the European Union for financial support obtained from FEDER funds
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Engineering Structures es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Compressed reinforcement buckling es_ES
dc.subject Critical buckling length es_ES
dc.subject Critical buckling load es_ES
dc.subject Fibre-reinforced concrete es_ES
dc.subject.classification INGENIERIA DE LA CONSTRUCCION es_ES
dc.title Mixed model for the analytical determination of critical buckling load of passive reinforcement in compressed RC and FRC elements under monotonic loading es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.engstruct.2017.07.026 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//BIA2012-32645/ES/ESTRATEGIAS DE MEJORA DE LA DUCTILIDAD FRENTE A ACCIONES SISMICAS DE UNIONES DE ELEMENTOS PREFABRICADOS MEDIANTE EL EMPLEO DE NUEVOS MATERIALES/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil es_ES
dc.description.bibliographicCitation Pereiro Barceló, J.; Bonet Senach, JL. (2017). Mixed model for the analytical determination of critical buckling load of passive reinforcement in compressed RC and FRC elements under monotonic loading. Engineering Structures. 150(1):76-90. https://doi.org/10.1016/j.engstruct.2017.07.026 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.engstruct.2017.07.026 es_ES
dc.description.upvformatpinicio 76 es_ES
dc.description.upvformatpfin 90 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 150 es_ES
dc.description.issue 1 es_ES
dc.relation.pasarela S\341340 es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem