Monitorización del ritmo, frecuencia y profundidad de respiración mediante mapas de profundidad

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Monitorización del ritmo, frecuencia y profundidad de respiración mediante mapas de profundidad

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Page Del Pozo, Alvaro Felipe es_ES
dc.contributor.author Álvarez Caballero, María Gloria es_ES
dc.date.accessioned 2017-12-28T15:54:27Z
dc.date.available 2017-12-28T15:54:27Z
dc.date.created 2017-09-28
dc.date.issued 2017-12-28 es_ES
dc.identifier.uri http://hdl.handle.net/10251/93522
dc.description.abstract [ES] En el ámbito clínico, la caracterización de la respiración se realiza con equipos específicos. En aplicaciones ambulatorias, los dispositivos comerciales disponibles para monitorizar la respiración se basan en sensores que deben colocarse sobre el cuerpo del sujeto. En cualquier caso, estas tecnologías implican contacto con el paciente, llegando a ser incluso invasivas en algunos casos, lo que limita su aplicación en campos como la detección de la somnolencia y fatiga durante la conducción. El objetivo del presente trabajo es desarrollar una técnica de monitorización de la respiración mediante mapas de profundidad obtenidos con un sistema de bajo coste y sin contacto (Kinect). Para ello, se ha estudiado la fiabilidad de la tecnología, confirmándose que la precisión óptima se obtiene dentro de un rango de operabilidad de entre 0.8 y 1.5 m, con una división del tronco del sujeto en regiones de interés móviles de un mínimo de 1470 puntos. Además, la técnica ha sido validada con la tecnología estándar para el análisis de movimientos humanos: la videofotogrametría (Kinescan/IBV). El procesamiento de los mapas de profundidad se ha realizado de dos maneras distintas. En primer lugar, el análisis biomecánico del movimiento finito del tronco y de sus deformaciones infinitesimales nos permite caracterizar la frecuencia y profundidad de la respiración para, de esta manera, poder reconocer la metodología empleada por el paciente y/o la presencia de patologías. En segundo lugar, el análisis de componentes principales nos permite identificar y discriminar los factores relacionados con la ropa y el género que afectan a la distorsión de las medidas. Estos factores son, en el caso de la ropa, el corte o caída de la prenda, su holgura y el efecto de sus arrugas. En el caso del género son determinantes la morfología anatómica, la curvatura del tronco y la asimetría mamaria. es_ES
dc.description.abstract [EN] In the clinical setting, the characterization of breathing is performed with specific equipment. In outpatient applications, commercially available devices for respiratory monitoring are based on sensors that must be placed on the subject's body. In any case, these technologies need to be in contact with the patient, becoming even invasive in some cases. This limits its application in fields such as the detection of drowsiness and fatigue during driving. The objective of the present work is to develop a technique for respiratory monitoring using depth maps obtained with a low cost and non-contact system (Kinect). Consequently, the reliability of the technology has been studied. This confirmed that the optimum precision is obtained within a range of operability between 0.8 and 1.5 m. Moreover, the division of the subject's trunk should be performed into mobile regions of interest with a minimum of 1470 points. The technique has been validated with the standard technology for the analysis of human movements: video photogrammetry (Kinescan/IBV). The processing of depth maps has been accomplished in two different ways. Firstly, the biomechanical analysis of the finite trunk movement and its infinitesimal deformations. This allows us to characterize the frequency and depth of respiration in order to recognize the methodology used by the patient and the presence of pathologies. Secondly, the principal components analysis allows us to identify and discriminate the factors related to clothing and gender which affect the distortion of measures. These factors are the cut or fall of the garment, its slack and the effect of its wrinkles in the case of clothing. In the case of gender, anatomical morphology, trunk curvature and mammary asymmetry are determinants. es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Non-contact es_ES
dc.subject Kinect depth camera es_ES
dc.subject respiratory motion tracking es_ES
dc.subject biomechanical analysis es_ES
dc.subject PCA. es_ES
dc.subject Sin contacto es_ES
dc.subject cámara de profundidad Kinect es_ES
dc.subject monitorización del movimiento respiratorio es_ES
dc.subject análisis biomecánico es_ES
dc.subject ACP. es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.other Máster Universitario en Ingeniería Biomédica-Màster Universitari en Enginyeria Biomèdica es_ES
dc.title Monitorización del ritmo, frecuencia y profundidad de respiración mediante mapas de profundidad es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Álvarez Caballero, MG. (2017). Monitorización del ritmo, frecuencia y profundidad de respiración mediante mapas de profundidad. http://hdl.handle.net/10251/93522 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\70901 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem