- -

Electrocardiographic reference values for healthy Netherland Dwarf rabbits and the influence of body position, age and gender

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Electrocardiographic reference values for healthy Netherland Dwarf rabbits and the influence of body position, age and gender

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Chapel, J. M. es_ES
dc.contributor.author Castillo, C. es_ES
dc.contributor.author Hernández, J. es_ES
dc.contributor.author Cipone, M. es_ES
dc.contributor.author Benedito, J. L. es_ES
dc.date.accessioned 2018-01-04T13:58:47Z
dc.date.available 2018-01-04T13:58:47Z
dc.date.issued 2017-12-28
dc.identifier.issn 1257-5011
dc.identifier.uri http://hdl.handle.net/10251/93941
dc.description.abstract [EN] The aim of this study was to provide reference values for a single, popular breed of pet rabbit. Moreover, additional objectives were to determine whether sex, body position or age alter Netherland Dwarf rabbit electrocardiographic variables and whether the use of electrocardiographic filters affects those variables. Forty Netherland Dwarf rabbits were examined clinically and standard six-lead electrocardiograms (ECGs) were recorded in sternal and then dorsal recumbency. At first power-line and anti-drift filters were used and then they were disabled. The following variables were measured in lead II: heart rate; P wave duration and amplitude; P-R interval; QRS duration; R wave amplitude (with and without filters); Q-T interval; T wave duration and amplitude; S-T segment; J-T duration; and mean electrical axis (MEA) (with and without filters). MEA was determined by 3 different methods. After statistical processing of the data, our results showed that there were no significant differences between both recumbencies, with the exception of the J-T duration, which was higher in dorsal recumbency. The R wave amplitude using electrocardiographic filters showed significant differences between males (0.083 mV) and females (0.115 mV; P<0.05); and between younger rabbits (0.108 mV) and older rabbits (0.097 mV; P<0.05). These differences were not shown between R waves with filters disabled. Moreover, the strongest correlation was between 2 MEA methods without filters. MEA was more leftward in the pet rabbit than in other species (dog or cats). In conclusion, electrocardiography recording without electrocardiographic filters should be assessed when it is possible, and the specific ECGs characteristics for Netherland Dwarf rabbit should be taken into account. es_ES
dc.description.sponsorship J. M. Chapel held a research fellowship (Ref. Plan I2C) from the organization Xunta de Galicia (Spain). The authors thank C.R. Hughes for his grammar review. es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València
dc.relation.ispartof World Rabbit Science
dc.rights Reserva de todos los derechos es_ES
dc.subject Electrocardiography es_ES
dc.subject Heart es_ES
dc.subject Filters es_ES
dc.subject Mean electrical axis es_ES
dc.subject Rabbit es_ES
dc.title Electrocardiographic reference values for healthy Netherland Dwarf rabbits and the influence of body position, age and gender es_ES
dc.type Artículo es_ES
dc.date.updated 2018-01-04T11:44:08Z
dc.identifier.doi 10.4995/wrs.2017.7424
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Chapel, JM.; Castillo, C.; Hernández, J.; Cipone, M.; Benedito, JL. (2017). Electrocardiographic reference values for healthy Netherland Dwarf rabbits and the influence of body position, age and gender. World Rabbit Science. 25(4):399-406. https://doi.org/10.4995/wrs.2017.7424 es_ES
dc.description.accrualMethod SWORD es_ES
dc.relation.publisherversion https://doi.org/10.4995/wrs.2017.7424 es_ES
dc.description.upvformatpinicio 399 es_ES
dc.description.upvformatpfin 406 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 25
dc.description.issue 4
dc.identifier.eissn 1989-8886
dc.contributor.funder Xunta de Galicia


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem