Diseño y desarrollo de un modelo computacional del efecto del campo eléctrico sobre la actividad neuronal de la médula espinal

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Diseño y desarrollo de un modelo computacional del efecto del campo eléctrico sobre la actividad neuronal de la médula espinal

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Saiz Rodríguez, Francisco Javier es_ES
dc.contributor.author Solanes Galbis, Carmen es_ES
dc.date.accessioned 2018-01-08T18:57:58Z
dc.date.available 2018-01-08T18:57:58Z
dc.date.created 2017-07-27
dc.date.issued 2018-01-08 es_ES
dc.identifier.uri http://hdl.handle.net/10251/94110
dc.description.abstract [ES] La estimulación de médula espinal (EME) es una terapia que se ha estado usando durante más de 40 años para el tratamiento de diferentes condiciones de dolor crónico. Esta terapia consiste en estimular las grandes fibras nerviosas Aß de los dermatomas correspondientes a las áreas donde el paciente siente dolor para producir parestesia. Aunque su uso clínico es elevado, todavía se desconoce el efecto de ciertos factores sobre el alcance del umbral de molestia de la estimulación. Dicho umbral limita la eficacia de la terapia, ya que impide el aumento del campo eléctrico para estimular las fibras nerviosas necesarias para aliviar el dolor. Muchos trabajos se han centrado en determinar los factores que afectan a la eficacia de la terapia de EME. Algunos de esos factores son: la polaridad de los electrodos, la geometría de la médula espinal, la distancia entre los contactos de los electrodos o la distancia entre el electrodo y la médula espinal. Con el objetivo de conocer mejor el efecto de estos factores, así como las mejores condiciones para lograr la máxima eficacia de la terapia de EME, en este trabajo se va a elaborar un modelo 3D de médula espinal. Para ello, primero se desarrollará un modelo de conductor volumétrico de médula espinal realista que permita simular el campo eléctrico y calcular el potencial eléctrico en los nodos de Ranvier. Luego se realizará un modelo de fibra nerviosa que simule la propagación del potencial de acción sobre la misma y, por tanto, el efecto del campo eléctrico sobre su activación. Finalmente, ambos modelos se usarán conjuntamente para el estudio de los diversos factores que afectan a la eficacia de la terapia de EME. es_ES
dc.description.abstract [EN] Spinal cord stimulation (SCS) therapy has been using for more than 40 years to treat different chronic pain conditions. This therapy consists on producing paresthesia by stimulating big Aß nerve fibers from dermatomas that correspond to painful areas of the patient. Despite its wide clinic use, the effects on the scope on discomfort threshold are still unknown. Discomfort threshold limits SCS therapy efficacy because it prevents increasing the electric field to stimulate all necessary nerve fibers to relieve pain. There are works in the literature focused on establishing the factors that affect SCS therapy efficacy. According to these works, the main factors are: electrodes polarity, spinal cord geometry, distance between electrodes contacts or distance between electrode and spinal cord. With the aim of knowing better the effect of this factors, as well as the best conditions to obtain the maximum SCS therapy efficacy, this work presents the development of a 3D spinal cord model. To do this, in first place, a realistic volumetric conductor model of the spinal cord that allows simulate the electric field is presented, in addition to the computation of the electric potential in Ranvier nodes. Then, a nerve fiber model to simulate the action potential propagation is realized in order to study the effect of the electric field when the activation is befallen. Finally, both models are used together to study several factors affecting directly to the SCS therapy efficacy. es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject spinal cord stimulation es_ES
dc.subject nerve fiber model es_ES
dc.subject volumetric conductor model es_ES
dc.subject discomfort threshold es_ES
dc.subject dorsal columns es_ES
dc.subject dorsal roots es_ES
dc.subject perception threshold es_ES
dc.subject electrode configuration. es_ES
dc.subject estimulación de médula espinal es_ES
dc.subject modelo de fibra nerviosa es_ES
dc.subject modelo de conductor volumétrico es_ES
dc.subject umbral de molestia es_ES
dc.subject cordones posteriores es_ES
dc.subject raíces dorsales es_ES
dc.subject umbral de percepción es_ES
dc.subject configuración del electrodo. es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.subject.other Máster Universitario en Ingeniería Biomédica-Màster Universitari en Enginyeria Biomèdica es_ES
dc.title Diseño y desarrollo de un modelo computacional del efecto del campo eléctrico sobre la actividad neuronal de la médula espinal es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Solanes Galbis, C. (2017). Diseño y desarrollo de un modelo computacional del efecto del campo eléctrico sobre la actividad neuronal de la médula espinal. http://hdl.handle.net/10251/94110 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\70915 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem