Mostrar el registro sencillo del ítem
dc.contributor.author | Abad Fuentes, Antonio | es_ES |
dc.contributor.author | Manclus Ciscar, Juan José | es_ES |
dc.contributor.author | March Iborra, Mª Del Carmen | es_ES |
dc.contributor.author | Montoya, Ángel | es_ES |
dc.date.accessioned | 2018-01-17T09:36:07Z | |
dc.date.available | 2018-01-17T09:36:07Z | |
dc.date.issued | 1993 | es_ES |
dc.identifier.issn | 0003-2700 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/94982 | |
dc.description.abstract | [EN] A competitive enzyme-linked immunosorbent assay (ELISA) based on monoclonal antibodies was developed to measure nicotine in smoke condensates of cigarettes. The ELISA standard curve displays a detection limit of 70 ng/mL and an effective working range of 0.3-4.0 mug of nicotine/mL. Using standard samples, ELISA results compare well with theoretical values (r = 0.997). The suitability of the method for industrial routine application was evaluated by measuring the nicotine concentration in 245 cigarette smoke condensates. When ELISA results were compared with those obtained by gas chromatography, a correlation coefficient r = 0.886 was obtained. The assay allows the specific, precise, and accurate determination of nicotine, without any significant interference from other alkaloids also present in tobacco smoke. Preliminary data suggest that the immunoassay could also be applied to other matrices, e.g., tobacco extracts. ELISA equipment requirements are minimum, simple, and low-cost, and an unskilled person could perform 150 analysis in a working day. On the basis of these features, ELISA is proposed as a promising alternative to instrumental methods for some industrial applications. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | American Chemical Society | es_ES |
dc.relation.ispartof | Analytical Chemistry | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Comparison of a monoclonal antibody-based enzyme-linked immunosorbent assay and gas chromatography for the determination of nicotine in cigarette smoke condensates | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1021/ac00070a010 | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano - Institut Interuniversitari d'Investigació en Bioenginyeria i Tecnologia Orientada a l'Ésser Humà | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Abad Fuentes, A.; Manclus Ciscar, JJ.; March Iborra, MDC.; Montoya, Á. (1993). Comparison of a monoclonal antibody-based enzyme-linked immunosorbent assay and gas chromatography for the determination of nicotine in cigarette smoke condensates. Analytical Chemistry. 65(22):3227-3231. doi:10.1021/ac00070a010 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1021/ac00070a010 | es_ES |
dc.description.upvformatpinicio | 3227 | es_ES |
dc.description.upvformatpfin | 3231 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 65 | es_ES |
dc.description.issue | 22 | es_ES |
dc.relation.pasarela | S\340728 | es_ES |