Mostrar el registro sencillo del ítem
dc.contributor.author | De Rosario Martínez, Helios | es_ES |
dc.contributor.author | Page Del Pozo, Alvaro Felipe | es_ES |
dc.contributor.author | Mata Amela, Vicente | es_ES |
dc.date.accessioned | 2018-02-19T05:18:36Z | |
dc.date.available | 2018-02-19T05:18:36Z | |
dc.date.issued | 2014 | es_ES |
dc.identifier.issn | 0021-9290 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/98071 | |
dc.description.abstract | [EN] This paper proposes a variation of the instantaneous helical pivot technique for locating centers of rotation. The point of optimal kinematic error (POKE), which minimizes the velocity at the center of rotation, may be obtained by just adding a weighting factor equal to the square of angular velocity in Woltring's equation of the pivot of instantaneous helical axes (PIHA). Calculations are simplified with respect to the original method, since it is not necessary to make explicit calculations of the helical axis, and the effect of accidental errors is reduced. The improved performance of this method was validated by simulations based on a functional calibration task for the gleno-humeral joint center. Noisy data caused a systematic dislocation of the calculated center of rotation towards the center of the arm marker cluster. This error in PIHA could even exceed the effect of soft tissue artifacts associated to small and medium deformations, but it was successfully reduced by the POKE estimation. | es_ES |
dc.description.sponsorship | This work has been funded by the Spanish Government (Grants DPI2009-13830-C02-01, DPI2009-13830-CO2-02, DPI2010-20814-CO2-01, DPI2010-20814-CO2-02). | |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Journal of Biomechanics | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Center of rotation | es_ES |
dc.subject | Instantaneous helical axis | es_ES |
dc.subject | Functional calibration | es_ES |
dc.subject | Optimization | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.subject.classification | INGENIERIA MECANICA | es_ES |
dc.title | Point of optimal kinematic error: Improvement of the instantaneous helical pivot method for locating centers of rotation | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.jbiomech.2014.02.003 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2009-13830-C02-01/ES/Modelado Cinematico Y Dinamico Del Movimiento De Los Tejidos Blandos. Aplicacion Al Diseño De Modelos Biomecanicos (Desarrollo E Implementacion De Modelos)/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2010-20814-C02-01/ES/IDENTIFICACION DE PARAMETROS DINAMICOS EN VEHICULOS LIGEROS Y ROBOTS MOVILES. APLICACION A LA IDENTIFICACION EN TIEMPO REAL./ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2009-13830-C02-02/ES/Modelado Cinematico Y Dinamico Del Movimiento De Los Tejidos Blandos. Aplicacion Al Diseño De Modelos Biomecanicos (Desarrollo De Tecnicas Experimentales Y Validacion De Modelos)/ | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2010-20814-C02-02/ES/IDENTIFICACION DE PARAMETROS DINAMICOS EN VEHICULOS LIGEROS Y ROBOTS MOVILES. APLICACION AL CONTROL Y LA NAVEGACION AUTOMATICA/ | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario Mixto de Biomecánica de Valencia - Institut Universitari Mixt de Biomecànica de València | es_ES |
dc.description.bibliographicCitation | De Rosario Martínez, H.; Page Del Pozo, AF.; Mata Amela, V. (2014). Point of optimal kinematic error: Improvement of the instantaneous helical pivot method for locating centers of rotation. Journal of Biomechanics. 47(7):1742-1747. doi:10.1016/j.jbiomech.2014.02.003 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.jbiomech.2014.02.003 | es_ES |
dc.description.upvformatpinicio | 1742 | es_ES |
dc.description.upvformatpfin | 1747 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 47 | es_ES |
dc.description.issue | 7 | es_ES |
dc.identifier.pmid | 24650972 | |
dc.relation.pasarela | S\271870 | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |