dc.description.abstract | [ES] El estudio abarca el análisis del comportamiento sísmico del Hospital Olive View, localizado en San Fernando, California (Los Ángeles, Estados Unidos), a través de la norma ISO/28841/2013, en la cual estudiamos las irregularidades en planta y alzado, así como los daños sufridos durante el terremoto. Se estudian y se analizan diferentes cuestiones estructurales debidas a decisiones en el diseño de proyecto y una propuesta de un nuevo diseño estructural. El edificio tiene una estructura de hormigón armado, formado por pórticos en las dos primeras plantas y pórticos y muros de cortante en las plantas superiores. Presenta un total de cinco niveles más un nivel semisubterráneo que tomaremos como planta baja y un altillo. El esquema se puede describir como una estructura de caja de cuatro pisos apoyados en dos niveles de pórticos. Este Hospital sufrió numerosos daños que provocaron el colapso estructural, lo que obligó a su posterior demolición. Entre ellos podemos encontrar el fallo de las columnas por falta de confinamiento y falta de armadura de cortante; irregularidades en la distribución de masas, rigideces y resistencias; elementos no monolíticos con la estructura; golpeteo de la estructura contra el muro de contención por fallo en el espesor de la junta sísmica y fallos en los elementos no estructurales. También se propondrá como posible solución la de aislar la cimentación del edificio por medio de apoyos o aisladores elastoméricos de base, debido a que es una solución que se está utilizando actualmente por su buen comportamiento sismoresistente. | es_ES |
dc.description.abstract | [EN] The study includes the analysis of a hospital seismic behaviour, specifically the Olive View Hospital, located in San Fernando, California (Los Angeles, USA), through the ISO/28841/2013 standard, in which we study floor plan and elevation irregularities, as well as damages caused during the earthquake. It is studied and analyzed the different structural issues due to decisions on the project design and a suggestion of a new structural design for the building. This one has a reinforced concrete structure composed of porches on the ground and first floors, and porches and shear walls on the upper floors, it presents a total of five levels along with a semi-subterranean level which we take as ground floor and attic floor. The scheme could be described as a box structure supported by four floors on two porches levels. This Hospital was hardly damaged, which caused structural collapse, forcing its subsequent demolition. Among them, we can find the columns' failure due to the lack of confinement and shear reinforcement, irregularities in masses distribution, stiffness and resistance; not monolithic elements with structure; knocking of the structure against the counting wall due to failure in the thickness of the seismic board and non-structural elements. It will also be proposed as a possible solution to isolate the building foundations through supports or elastomeric base isolators since it is a solution that is currently being used because of its good seismic-resistant behaviour. | es_ES |
dc.format.extent | 62 | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Earthquakes | es_ES |
dc.subject | Seismic analysis | es_ES |
dc.subject | Seismic prevention | es_ES |
dc.subject | Hospital Olive View | es_ES |
dc.subject | San Fernando (California, USA) | es_ES |
dc.subject | Terremotos | es_ES |
dc.subject | Análisis sísmico | es_ES |
dc.subject | Prevención sísmica | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.subject.other | Grado en Fundamentos de la Arquitectura-Grau en Fonaments de l'Arquitectura | es_ES |
dc.title | Respuesta sísmica del hospital Olive View durante el terremoto de San Fernando de 1971: propuesta de un nuevo diseño estructural | es_ES |
dc.type | Proyecto/Trabajo fin de carrera/grado | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.description.bibliographicCitation | Torres Galiano, ML. (2016). Respuesta sísmica del hospital Olive View durante el terremoto de San Fernando de 1971: propuesta de un nuevo diseño estructural. http://hdl.handle.net/10251/98325 | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\52264 | es_ES |