Detection of Broken Outer-Cage Bars for Double-Cage Induction Motors Under the Startup Transient

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Detection of Broken Outer-Cage Bars for Double-Cage Induction Motors Under the Startup Transient

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Antonino-Daviu, J. es_ES
dc.contributor.author Riera-Guasp, Martín es_ES
dc.contributor.author Pons Llinares, Joan es_ES
dc.contributor.author Park, Jongbin es_ES
dc.contributor.author Lee, Sang Bin es_ES
dc.contributor.author Yoo, Jiyoon es_ES
dc.contributor.author Kral, Christian es_ES
dc.date.accessioned 2018-03-17T05:16:08Z
dc.date.available 2018-03-17T05:16:08Z
dc.date.issued 2012 es_ES
dc.identifier.issn 0093-9994 es_ES
dc.identifier.uri http://hdl.handle.net/10251/99470
dc.description (c) 2009 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
dc.description.abstract [EN] Unlike single-cage rotor fault detection, fast Fourier transform (FFT)-based steady-state spectrum analysis techniques can fail to detect outer-cage faults in double-cage induction motors due to the small outer-cage current under running conditions. Double-cage motors are typically employed in applications that require loaded starts. This makes the outer cage vulnerable to fatigue failure since it must withstand the high starting current and long startup time frequently. However, there are only a few publications that investigate detection techniques specifically for double-cage motors. In this paper, considering that the influence of the faulty outer cage is strong at startup due to the large outer-cage current, detection of outer-cage faults under the startup transient is investigated. A discrete-wavelet-transform-based method is proposed as a viable solution to the detection of outer-cage faults for double-cage motors. An experimental study on fabricated copper double-cage induction motors shows that the proposed method provides sensitive and reliable detection of double-cage rotor faults compared to FFT. es_ES
dc.description.sponsorship This work was supported in part by the Spanish “Ministerio de Educación y Ciencia,” in the framework of the “Programa Nacional de Proyectos de Investigación Fundamental,” under Project Reference DPI2008-06583/DPI, and in part by the Human Resources Development of Korea Institute of Energy Technology Evaluation and Planning under Grant 20114010203010 funded by the Korean Government Ministry of Knowledge Economy
dc.language Inglés es_ES
dc.publisher Institute of Electrical and Electronics Engineers es_ES
dc.relation.ispartof IEEE Transactions on Industry Applications es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject AC machine es_ES
dc.subject Condition monitoring es_ES
dc.subject Double-cage rotor es_ES
dc.subject Fast Fourier transform (FFT) es_ES
dc.subject Fault diagnostics es_ES
dc.subject Induction motor es_ES
dc.subject Motor current signature analysis (MCSA) es_ES
dc.subject Outer-cage fault es_ES
dc.subject Transient analysis es_ES
dc.subject Wavelet transform es_ES
dc.subject.classification INGENIERIA ELECTRICA es_ES
dc.title Detection of Broken Outer-Cage Bars for Double-Cage Induction Motors Under the Startup Transient es_ES
dc.type Artículo es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.1109/TIA.2012.2210173 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//DPI2008-06583/ES/DESARROLLO DE TECNICAS DE DIAGNOSTICO DE AVERIAS ELECTROMECANICAS EN MAQUINAS ELECTRICAS DE INDUCCION BASADAS EN LA APLICACION DE METODOS AVANZADOS DE ANALISIS DE SEÑAL/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/NRF//20114010203010/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica es_ES
dc.description.bibliographicCitation Antonino-Daviu, J.; Riera-Guasp, M.; Pons Llinares, J.; Park, J.; Lee, SB.; Yoo, J.; Kral, C. (2012). Detection of Broken Outer-Cage Bars for Double-Cage Induction Motors Under the Startup Transient. IEEE Transactions on Industry Applications. 48(5):1539-1548. https://doi.org/10.1109/TIA.2012.2210173 es_ES
dc.description.accrualMethod S es_ES
dc.relation.conferencename 8TH IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives (SDEMPED 2011) es_ES
dc.relation.conferencedate September 05-08,2011 es_ES
dc.relation.conferenceplace Bolonia, Italy es_ES
dc.relation.publisherversion http://doi.org/10.1109/TIA.2012.2210173 es_ES
dc.description.upvformatpinicio 1539 es_ES
dc.description.upvformatpfin 1548 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 48 es_ES
dc.description.issue 5 es_ES
dc.relation.pasarela S\224247 es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder National Research Foundation of Korea


Este ítem aparece en la(s) siguiente(s) colección(ones)