Mostrar el registro sencillo del ítem
dc.contributor.author | Torrella Alcaraz, Enrique | es_ES |
dc.contributor.author | Llopis, R. | es_ES |
dc.contributor.author | Cabello, R. | es_ES |
dc.contributor.author | Sanchez, D. | es_ES |
dc.contributor.author | Larumbe, J.A. | es_ES |
dc.date.accessioned | 2018-03-23T13:31:36Z | |
dc.date.available | 2018-03-23T13:31:36Z | |
dc.date.issued | 2010 | es_ES |
dc.identifier.issn | 1742-8297 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/99666 | |
dc.description.abstract | [EN] This paper describes a Second Law Analysis based on experimental data of a two-stage vapour compression facility driven by a compound compressor for medium and low-capacity refrigeration applications, which operates with the most usual inter-stage configurations (direct liquid injection and subcooler). The experimental analysis is performed for an evaporating temperature range between 36 degrees C and 20 degrees C and for a condensing temperature range between 30 degrees C and 47 degrees C using the refrigerant R-404A. The final results are compared with energy analysis from previous works. Additionally, a new criterion of equivalence between the simple vapour compression cycle and the two-stage compression cycle is given. | es_ES |
dc.description.sponsorship | The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for their economic support to this work. | |
dc.language | Inglés | es_ES |
dc.publisher | Inderscience Enterprises Ltd. | es_ES |
dc.relation.ispartof | International Journal of Exergy | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | R-404A | es_ES |
dc.subject | Exergy analysis | es_ES |
dc.subject | Inter-stage pressure | es_ES |
dc.subject | Two-stage refrigerating cycle | es_ES |
dc.subject | Vapour compression | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.title | Second law analysis of two-stage vapour compression refrigeration plants | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1504/IJEX.2010.035512 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//CTM2008-06468-C02-01/ES/ESTRATEGIA DE AHORRO Y EFICIENCIA ENERGETICA EN PRODUCCION DE FRIO POR COMPRESION CON REFRIGERANTES HFC/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MARM//200800050084716/ES/RNCO2: NUEVAS TECNOLOGÍAS FRIGORÍFICAS DE COMPRESIÓN DE VAPOR CON UTILIZACIÓN DEL REFRIGERANTE NATURALL CO2 EN SUSTITUCIÓN DE LOS ACTUALES HFC/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.description.bibliographicCitation | Torrella Alcaraz, E.; Llopis, R.; Cabello, R.; Sanchez, D.; Larumbe, J. (2010). Second law analysis of two-stage vapour compression refrigeration plants. International Journal of Exergy. 7(6):641-653. https://doi.org/10.1504/IJEX.2010.035512 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1504/IJEX.2010.035512 | es_ES |
dc.description.upvformatpinicio | 641 | es_ES |
dc.description.upvformatpfin | 653 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 7 | es_ES |
dc.description.issue | 6 | es_ES |
dc.relation.pasarela | S\39682 | es_ES |
dc.contributor.funder | Ministerio de Educación y Ciencia | es_ES |
dc.contributor.funder | Ministerio de Medio Ambiente y Medio Rural y Marino | es_ES |