Experimental comparison between R152a and R134a working in a refrigeration facility equipped with a hermetic compressor

dc.contributor.authorCabello, R.es_ES
dc.contributor.authorSanchez, D.es_ES
dc.contributor.authorLlopis Doménech, Rodrigoes_ES
dc.contributor.authorArmendáriz Araúzo, Luis Migueles_ES
dc.contributor.authorTorrella Alcaraz, Enriquees_ES
dc.contributor.funderUniversitat Jaume I
dc.date.accessioned2018-03-09T05:10:31Z
dc.date.available2018-03-09T05:10:31Z
dc.date.issued2015es_ES
dc.description.abstract[EN] The EU Regulation 517/2014 has recently been approved in a further attempt to curb the effects of GlobalWarming. As a consequence, the refrigeration sector is moving towards refrigerants with a low GlobalWarming Potential (GWP100) in accordance with the limit fixed by these regulations (150). In this regard, the old refrigerant R152a attracts renewed interest due to its low GWP (138) and its similarity to R134a. The present work shows the results of using R152a in a vapour compression plant equipped with a hermetic compressor and an IHX designed for R134a. The refrigerant was replaced by a conventional drop-in process in order to carry out an energy comparison. The results have revealed an improvement in the COP with R152a up to 13% despite a reduction in the cooling capacity of about 10%. During the test campaign, R134a hermetic compressors have been shown to be capable of operating with R152a.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationCabello, R.; Sanchez, D.; Llopis Doménech, R.; Armendáriz Araúzo, LM.; Torrella Alcaraz, E. (2015). Experimental comparison between R152a and R134a working in a refrigeration facility equipped with a hermetic compressor. International Journal of Refrigeration. 60:92-105. https://doi.org/10.1016/j.ijrefrig.2015.06.021es_ES
dc.description.sponsorshipThe authors acknowledge Jaume I University of Spain, who financed partially the present study through the research project P1.B2013-10.en_EN
dc.description.upvformatpfin105es_ES
dc.description.upvformatpinicio92es_ES
dc.description.volume60es_ES
dc.identifier.doi10.1016/j.ijrefrig.2015.06.021es_ES
dc.identifier.issn0140-7007es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/99046
dc.languageIngléses_ES
dc.publisherElsevieres_ES
dc.relation.ispartofInternational Journal of Refrigerationes_ES
dc.relation.pasarelaS\305865es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/UJI//P1.B2013-10/
dc.relation.publisherversionhttps://doi.org/10.1016/j.ijrefrig.2015.06.021es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectR152aes_ES
dc.subjectR134aes_ES
dc.subjectF-gases_ES
dc.subjectHermetic compressores_ES
dc.subjectInternal heat exchangeres_ES
dc.subjectGWPes_ES
dc.subject.classificationMAQUINAS Y MOTORES TERMICOSes_ES
dc.titleExperimental comparison between R152a and R134a working in a refrigeration facility equipped with a hermetic compressores_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuid0d4c46f7-67ae-4a7d-a056-6d3aa4c1c4baes_ES

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
69429.pdf
Tamaño:
1.11 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión del Autor.
Cargando...
Miniatura
Nombre:
Experimental comparison between R152a and_2015.pdf
Tamaño:
3.6 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial