A non-parametric validation framework for photoplethysmography-based heart rate monitoring: a proof-of-concept study using the two-sample Kolmogorov–Smirnov test

dc.contributor.authorCruz-Salgado, Javieres_ES
dc.contributor.authorBautista-López, Roxana Zaricelles_ES
dc.contributor.authorYañez-Mendiola, Javieres_ES
dc.contributor.authorRuelas-Santoyo, Edgar Augustoes_ES
dc.contributor.authorMiguel-Andrés, Israeles_ES
dc.contributor.authorJiménez-García, José Alfredoes_ES
dc.date.accessioned2026-01-30T12:54:39Z
dc.date.available2026-01-30T12:54:39Z
dc.date.issued2026-11-27
dc.description.abstract[EN] This article introduces a statistical approach for comparing heart rate measurements obtained from two photoplethysmography (PPG) signals: one recorded with a commercial oximeter and the other acquired using a device based on photoplethysmography with synchronous detection. The study applies the two-sample Kolmogorov Smirnov test as a robust and versatile method for comparing the distributions of PPG signals. By integrating the two-sample Kolmogorov Smirnov test into the validation process of cardiac pulse measurement devices, the work demonstrates its effectiveness in enhancing the accuracy and reliability of biomedical signal analysis. Results show that, when comparing signals against calibrated reference devices and visualizing cumulative distribution functions, the two-sample Kolmogorov Smirnov test is capable of detecting subtle differences in signal behavior. This innovative use of the two-sample Kolmogorov Smirnov test provides valuable insights for the design and validation of biomedical signal processing systems and contributes to the advancement of non-invasive health monitoring technologies.en_EN
dc.description.accrualMethodOJSes_ES
dc.description.bibliographicCitationCruz-Salgado, J.; Bautista-López, RZ.; Yañez-Mendiola, J.; Ruelas-Santoyo, EA.; Miguel-Andrés, I.; Jiménez-García, JA. (2026). A non-parametric validation framework for photoplethysmography-based heart rate monitoring: a proof-of-concept study using the two-sample Kolmogorov–Smirnov test. Journal of Applied Research in Technology & Engineering. 7(1):58-70. https://riunet.upv.es/handle/10251/232181es_ES
dc.description.issue1es_ES
dc.description.upvformatpfin70
dc.description.upvformatpinicio58
dc.description.volume7es_ES
dc.identifier.eissn2695-8821es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/232181
dc.languageIngléses_ES
dc.publisherUniversitat Politècnica de Valènciaes_ES
dc.relation.ispartofJournal of Applied Research in Technology & Engineeringes_ES
dc.relation.pasarelaOJS\24883es_ES
dc.rightsReconocimiento - No comercial - Compartir igual (by-nc-sa)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectPhotoplethysmographyes_ES
dc.subjectTwo-sample Kolmogorov Smirnov testes_ES
dc.subjectHeart rate comparisones_ES
dc.subjectBiomedical signal processinges_ES
dc.subjectNon-invasive health monitoringes_ES
dc.titleA non-parametric validation framework for photoplethysmography-based heart rate monitoring: a proof-of-concept study using the two-sample Kolmogorov–Smirnov test
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublicationes_ES
upv.uuid1e660a64-2fe1-4bfa-a005-b7ed1b1f5a59es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Cruz-SalgadoBautista-LopezYanez-Mendiola - NON-PARAMETRIC VALIDATION OF PHOTOPLETHYSMOGRAPHY-BASE....pdf
Tamaño:
1.26 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial