Modal pushover and response history analyses of a masonry chimney before and after shortening

dc.contributor.authorMinghini, Fabioes_ES
dc.contributor.authorBertolesi, Elisaes_ES
dc.contributor.authorGrosso, Antonio Deles_ES
dc.contributor.authorMilani, Gabrielees_ES
dc.contributor.authorTralli, Antonioes_ES
dc.date.accessioned2018-09-17T08:21:47Z
dc.date.available2018-09-17T08:21:47Z
dc.date.issued2016es_ES
dc.description.abstract[EN] The 50 m high masonry chimney located in the old industrial facility that houses the School of Engineering of the University of Ferrara, Italy, suffered severe damages during the 2012 Emilia seismic sequence. Afterward, for security reasons, the upper damaged 12.40 m were disassembled. Both before and after shortening, the ratio between the effective mass of the fundamental mode and the total mass is approximately 20%, leading standard pushover analysis methods not to be appropriate for estimating the seismic demand. Using a single, consistent 3D FE formulation, the results of a Modal Pushover Analysis (MPA) and four nonlinear Response History Analyses (RHA) for the shortened and the original chimney were presented in the paper. The ground motions considered in the simulations are accelerograms recorded during recent and less recent devastating seismic events in Italy, New Zealand, and Japan. For both chimneys, a very good agreement between MPA and RHA was observed in terms of lateral displacements. Moreover, for the 50 m high chimney, a strong similarity was observed between the damage maps deriving from the MPA and those obtained with the RHA. All analyses confirmed a significant contribution of the higher modes. For the shortened chimney, the MPA revealed damages in the lower part of the stack (8¿21 m), because of a prevailing influence of the fundamental mode. In the RHA, a more evident contribution of the higher modes was observed, probably because of the effect of the vertical component of the ground motion, not accounted for in the MPA.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationMinghini, F.; Bertolesi, E.; Grosso, AD.; Milani, G.; Tralli, A. (2016). Modal pushover and response history analyses of a masonry chimney before and after shortening. Engineering Structures. 110:307-324. doi:10.1016/j.engstruct.2015.11.016es_ES
dc.description.upvformatpfin324es_ES
dc.description.upvformatpinicio307es_ES
dc.description.volume110es_ES
dc.identifier.doi10.1016/j.engstruct.2015.11.016es_ES
dc.identifier.issn0141-0296es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/107436
dc.languageIngléses_ES
dc.publisherElsevieres_ES
dc.relation.ispartofEngineering Structureses_ES
dc.relation.pasarelaS\357059es_ES
dc.relation.publisherversionhttps://doi.org/10.1016/j.engstruct.2015.11.016es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsCerradoes_ES
dc.subjectMasonry chimneyes_ES
dc.subjectModal pushover analysises_ES
dc.subjectNonlinear response history analysises_ES
dc.subjectHigher modeses_ES
dc.titleModal pushover and response history analyses of a masonry chimney before and after shorteninges_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuid26cdaa14-bfaf-410b-bb80-5d552b7d2b4ees_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Modal-pushover.pdf
Tamaño:
8.7 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial