Detection of Dominant Reentries in Multichannel Electrograms of Atrial Fibrillation

dc.contributor.affiliationDepartamento de Ingeniería Electrónica
dc.contributor.affiliationEscuela Politécnica Superior de Gandia
dc.contributor.affiliationBiosignals & Minimally Invasive Technologies-BioMIT
dc.contributor.authorVraka, Aikaterinies_ES
dc.contributor.authorOsorio, Diegoes_ES
dc.contributor.authorBertomeu-González, Vicentees_ES
dc.contributor.authorRavelli, Flaviaes_ES
dc.contributor.authorAlcaraz, Raúles_ES
dc.contributor.authorRieta, J J
dc.contributor.funderEuropean Regional Development Fundes_ES
dc.date.accessioned2022-02-07T08:29:23Z
dc.date.available2022-02-07T08:29:23Z
dc.date.issued2019-11-23es_ES
dc.description.abstract[EN] Algorithms developed so far for the detection of local activation waves (LAWs) in electrograms (EGMs) of atrial fibrillation (AF) analyze each channel of the catheter separately, while dominant reentries of AF are captured by most of the catheter channels simultaneously. This encompasses the risk of losing or oversensing activations in the case of complex fractionated atrial electrograms (CFAEs). The proposed method analyzes multichannel recordings of AF from the least to the most fractionated. Activations are manually annotated and then EGMs are denoised, band-pass filtered by an alternative Bot-teron approach and thresholded. LAW detection is performed sequentially on all the channels by ascending fractionation order. Activations in the first EGM are found by an amplitude-based search, followed by a cycle length (CL) based search. Detection algorithm in the remaining signals is based on the previously detected LAWs, applying a varying search window according to the repetition rate of each activation. A CL-based search is also applied and activation time is computed from the barycenter of each LAW. The final step contains a secondary control that deletes all the low amplitude activations showing low repetition rate, so that any bias regarding the LAW detection of the first EGM is avoided. The method was compared with the equivalent sequential single-channel analysis, with the former showing better accuracy (90.82%) and positive predictive value (96.52%) than the single-channel approach (89.65% and 92.70%, respectively). Multichannel analysis performed a more selective analysis, ignoring some obvious but not repeated LAWs. Consequently, it can localize AF triggers and propagation phenomena more robustly than single channel method.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationVraka, A.; Osorio, D.; Bertomeu-González, V.; Ravelli, F.; Alcaraz, R.; Rieta, JJ. (2019). Detection of Dominant Reentries in Multichannel Electrograms of Atrial Fibrillation. IEEE. 1-4. https://doi.org/10.1109/EHB47216.2019.8969992es_ES
dc.description.sponsorshipResearch supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.es_ES
dc.description.upvformatpfin4es_ES
dc.description.upvformatpinicio1es_ES
dc.identifier.doi10.1109/EHB47216.2019.8969992es_ES
dc.identifier.isbn978-1-7281-2603-6es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/180567
dc.languageIngléses_ES
dc.publisherIEEEes_ES
dc.relation.conferencedateNoviembre 21-23,2019es_ES
dc.relation.conferencenameInternational Conference on e-Health and Bioengineering (EHB 2019)es_ES
dc.relation.conferenceplaceIasi, Romaniaes_ES
dc.relation.ispartof2019 E-Health and Bioengineering Conference (EHB)es_ES
dc.relation.pasarelaS\411541es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-83952-C3-1-R/ES/ESTUDIO MULTICENTRICO PARA LA EVALUACION DEL SUSTRATO ARRITMOGENICO EN PACIENTES CON FIBRILACION AURICULAR. APLICACION A LA ABLACION POR CATETER/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/JCCM//SBPLY%2F17%2F180501%2F000411//Caracterización del sustrato auricular mediante análisis de señal como herramienta de asistencia procedimental en ablación por catéter de fibrilación auricular/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/GVA//AICO%2F2019%2F036/ES/METODOS DE DIAGNOSTICO Y TERAPIA PERSONALIZADA EN ABLACION POR CATETER DE ARRITMIAS CARDIACAS/es_ES
dc.relation.publisherversionhttps://doi.org/10.1109/EHB47216.2019.8969992es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectAtrial fibrillationes_ES
dc.subjectCatheter ablationes_ES
dc.subjectComplex fractionated atrial electrogramses_ES
dc.subjectMultichanneles_ES
dc.subjectLocal activation waveses_ES
dc.subject.classificationTECNOLOGIA ELECTRONICAes_ES
dc.titleDetection of Dominant Reentries in Multichannel Electrograms of Atrial Fibrillationes_ES
dc.typeComunicación en congresoes_ES
dc.typeCapítulo de libroes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
person.identifier1382
person.identifier.orcid0000-0002-3364-6380
relation.isAuthorOfPublication702812f9-84b3-422f-8694-27b2e37a694a
relation.isAuthorOfPublication.latestForDiscovery702812f9-84b3-422f-8694-27b2e37a694a
relation.isOrgUnitOfPublicationa3ca7df3-e467-4f69-b673-79a5d6241220
relation.isOrgUnitOfPublication1db03441-9881-4e7e-a0a9-daca18341155
relation.isOrgUnitOfPublicationb59b88ae-bd83-460a-8f2a-1dc9e04478f4
relation.isOrgUnitOfPublication.latestForDiscoverya3ca7df3-e467-4f69-b673-79a5d6241220
upv.uuid2fdff4b6-88a2-47d9-88ab-e18835c28f37es_ES

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
VrakaOsorioBertomeu-Gonzalez - Detection of Dominant Reentries in Multichannel Electrograms of At....pdf
Tamaño:
1.25 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión del Autor.
Cargando...
Miniatura
Nombre:
20191022_EHB_MLAW_Vraka_R12_actas.pdf
Tamaño:
1.41 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial