The Relevance of Heart Rate Fluctuation When Evaluating Atrial Substrate Electrical Features in Catheter Ablation of Paroxysmal Atrial Fibrillation

dc.contributor.authorVraka, Aikaterinies_ES
dc.contributor.authorMoreno-Arribas, Josées_ES
dc.contributor.authorGracia-Baena, Juan M.es_ES
dc.contributor.authorHornero, Fernandoes_ES
dc.contributor.authorAlcaraz, Raúles_ES
dc.contributor.authorRieta, J Jes_ES
dc.contributor.funderGENERALITAT VALENCIANAes_ES
dc.contributor.funderAGENCIA ESTATAL DE INVESTIGACIONes_ES
dc.contributor.funderAgencia Estatal de Investigaciónes_ES
dc.contributor.funderConsejería de Educación, Cultura y Deportes de la Junta de Comunidades de Castilla-La Manchaes_ES
dc.date.accessioned2022-11-07T19:01:48Z
dc.date.available2022-11-07T19:01:48Z
dc.date.issued2022-06-01es_ES
dc.description.abstract[EN] Coronary sinus (CS) catheterization is critical during catheter ablation (CA) of atrial fibrillation (AF). However, the association of CS electrical activity with atrial substrate modification has been barely investigated and mostly limited to analyses during AF. In sinus rhythm (SR), atrial substrate modification is principally assessed at a global level through P-wave analysis. Cross-correlating CS electrograms (EGMs) and P-waves' features could potentiate the understanding of AF mechanisms. Five-minute surface lead II and bipolar CS recordings before, during, and after CA were acquired from 40 paroxysmal AF patients. Features related to duration, amplitude, and heart-rate variability of atrial activations were evaluated. Heart-rate adjustment (HRA) was applied. Correlations between each P-wave and CS local activation wave (LAW) feature were computed with cross-quadratic sample entropy (CQSE), Pearson correlation (PC), and linear regression (LR) with 10-fold cross-validation. The effect of CA between different ablation steps was compared with PC. Linear correlations: poor to mediocre before HRA for analysis at each P-wave/LAW (PC: max. +18.36%, p = 0.0017, LR: max. +5.33%, p = 0.0002) and comparison between two ablation steps (max. +54.07%, p = 0.0205). HRA significantly enhanced these relationships, especially in duration (P-wave/LAW: +43.82% to +69.91%, p < 0.0001 for PC and +18.97% to +47.25%, p < 0.0001 for LR, CA effect: +53.90% to +85.72%, p < 0.0210). CQSE reported negligent correlations (0.6-1.2). Direct analysis of CS features is unreliable to evaluate atrial substrate modification due to CA. HRA substantially solves this problem, potentiating correlation with P-wave features. Hence, its application is highly recommended.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationVraka, A.; Moreno-Arribas, J.; Gracia-Baena, JM.; Hornero, F.; Alcaraz, R.; Rieta, JJ. (2022). The Relevance of Heart Rate Fluctuation When Evaluating Atrial Substrate Electrical Features in Catheter Ablation of Paroxysmal Atrial Fibrillation. Journal of Cardiovascular Development and Disease. 9(6):1-16. https://doi.org/10.3390/jcdd9060176es_ES
dc.description.issue6es_ES
dc.description.sponsorshipThis research received partial financial support from public grants DPI2017-83952-C3, PID2021-00X128525-IV0, PID2021-123804OB-I00. and TED2021-129996B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SB-PLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha. and AICO/2021/286 from Generalitat Valenciana.es_ES
dc.description.upvformatpfin16es_ES
dc.description.upvformatpinicio1es_ES
dc.description.volume9es_ES
dc.identifier.doi10.3390/jcdd9060176es_ES
dc.identifier.eissn2308-3425es_ES
dc.identifier.pmcidPMC9224671es_ES
dc.identifier.pmid35735805es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/189388
dc.languageIngléses_ES
dc.publisherMDPI AGes_ES
dc.relation.ispartofJournal of Cardiovascular Development and Diseasees_ES
dc.relation.pasarelaS\468029es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-83952-C3-1-R/ES/ESTUDIO MULTICENTRICO PARA LA EVALUACION DEL SUSTRATO ARRITMOGENICO EN PACIENTES CON FIBRILACION AURICULAR. APLICACION A LA ABLACION POR CATETER/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/GVA//AICO%2F2021%2F286//Inteligencia Artificial para Revolucionar la Medicina Móvil Usando Dispositivos Llevables/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI//PID2021-123804OB-I00//INTELIGENCIA ARTIFICIAL PARA LA MEDICINA MÓVIL INNOVADORA EN ENFERMEDADES CARDIOVASCULARES/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/Consejería de Educación, Cultura y Deportes de la Junta de Comunidades de Castilla-La Mancha//SBPLY%2F17%2F180501%2F000411//Caracterización del sustrato auricular mediante análisis de señal como herramienta de asistencia procedimental en ablación por catéter de fibrilación auricular/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI//PID2021-00X128525-IV0/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI//TED2021-129996B-I00/es_ES
dc.relation.publisherversionhttps://doi.org/10.3390/jcdd9060176es_ES
dc.relation.references10.1161/CIR.0000000000000757es_ES
dc.relation.references10.1093/eurheartj/ehaa612ses_ES
dc.relation.references10.1056/NEJM199809033391003es_ES
dc.relation.references10.1055/s-2007-1013198es_ES
dc.relation.references10.1016/S1062-1458(02)00739-0es_ES
dc.relation.references10.1016/j.hrthm.2019.03.028es_ES
dc.relation.references10.1016/j.hlc.2017.05.119es_ES
dc.relation.references10.1016/j.jcmg.2016.11.003es_ES
dc.relation.references10.1093/europace/euw376es_ES
dc.relation.references10.1007/s10840-019-00576-1es_ES
dc.relation.references10.1186/s12947-021-00250-5es_ES
dc.relation.references10.1016/j.jelectrocard.2021.10.003es_ES
dc.relation.references10.3390/jpm12030462es_ES
dc.relation.references10.1016/j.hrthm.2017.02.030es_ES
dc.relation.references10.1002/joa3.12379es_ES
dc.relation.references10.1161/01.CIR.98.17.1790es_ES
dc.relation.references10.1046/j.1540-8167.2001.01187.xes_ES
dc.relation.references10.1046/j.1460-9592.2002.00414.xes_ES
dc.relation.references10.1159/000501819es_ES
dc.relation.references10.1111/pace.14026es_ES
dc.relation.references10.1016/j.hrthm.2011.11.041es_ES
dc.relation.references10.1046/j.1540-8167.2003.03222.xes_ES
dc.relation.references10.1111/j.1540-8167.2007.00764.xes_ES
dc.relation.references10.1111/j.1540-8167.2008.01175.xes_ES
dc.relation.references10.1016/j.hrthm.2013.06.007es_ES
dc.relation.references10.1161/JAHA.116.004869es_ES
dc.relation.references10.1016/j.hrthm.2009.11.024es_ES
dc.relation.references10.1016/j.hrthm.2010.05.011es_ES
dc.relation.references10.1016/j.ijcard.2019.10.044es_ES
dc.relation.references10.4022/jafib.1809es_ES
dc.relation.references10.1016/B978-075067572-7.50011-4es_ES
dc.relation.references10.1016/S0022-0736(97)80013-1es_ES
dc.relation.references10.1093/europace/eup410es_ES
dc.relation.references10.1016/j.ijcard.2010.08.029es_ES
dc.relation.references10.5935/abc.20130214es_ES
dc.relation.references10.1016/j.jelectrocard.2014.04.010es_ES
dc.relation.references10.1111/anec.12240es_ES
dc.relation.references10.1111/anec.12364es_ES
dc.relation.references10.1016/j.bspc.2021.102500es_ES
dc.relation.references10.1016/0002-9149(82)90471-4es_ES
dc.relation.references10.1111/jce.14070es_ES
dc.relation.references10.1111/anec.12653es_ES
dc.relation.references10.3390/s22010290es_ES
dc.relation.references10.1093/oxfordjournals.eurheartj.a014868es_ES
dc.relation.references10.1111/jce.12402es_ES
dc.relation.references10.1016/j.amjcard.2019.08.025es_ES
dc.relation.references10.1016/j.jelectrocard.2003.09.021es_ES
dc.relation.references10.1161/01.CIR.100.22.2237es_ES
dc.relation.references10.1111/jce.14448es_ES
dc.relation.references10.1111/pace.14408es_ES
dc.relation.references10.1002/9780471740360.ebs1482es_ES
dc.relation.references10.1088/1361-6579/aae8b1es_ES
dc.relation.references10.1109/IEMBS.2011.6091162es_ES
dc.relation.references10.3389/fphys.2018.00922es_ES
dc.relation.references10.1109/IEMBS.2010.5626498es_ES
dc.relation.references10.22489/CinC.2017.236-033es_ES
dc.relation.references10.1088/0967-3334/29/12/001es_ES
dc.relation.references10.1088/1361-6579/ab2cb8es_ES
dc.relation.references10.22489/CinC.2017.202-031es_ES
dc.relation.references10.1109/EHB50910.2020.9280243es_ES
dc.relation.references10.1038/s41598-020-59480-8es_ES
dc.relation.references10.1142/9789812834119_0002es_ES
dc.relation.references10.1016/S0076-6879(00)21192-0es_ES
dc.relation.references10.1016/j.bspc.2013.01.009es_ES
dc.relation.references10.1152/ajpheart.00561.2010es_ES
dc.relation.references10.3390/e22020232es_ES
dc.relation.references10.1093/europace/euab254es_ES
dc.relation.references10.1002/bem.22115es_ES
dc.relation.references10.33549/physiolres.934425es_ES
dc.relation.references10.1161/CIRCRESAHA.114.303772es_ES
dc.relation.references10.1088/0967-3334/33/12/1959es_ES
dc.relation.references10.1161/CIRCEP.119.007700es_ES
dc.relation.references10.1111/j.1540-8159.1998.tb01064.xes_ES
dc.relation.references10.1109/IEMBS.2011.6091408es_ES
dc.relation.references10.1161/JAHA.120.017069es_ES
dc.rightsReconocimiento (by)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectAtrial fibrillationes_ES
dc.subjectCatheter ablationes_ES
dc.subjectCoronary sinuses_ES
dc.subjectP-waveses_ES
dc.subjectCorrelationes_ES
dc.subjectAtrial substratees_ES
dc.subjectInvasive recordingses_ES
dc.subjectHeart-rate adjustmentes_ES
dc.titleThe Relevance of Heart Rate Fluctuation When Evaluating Atrial Substrate Electrical Features in Catheter Ablation of Paroxysmal Atrial Fibrillationes_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
opencost.amount.paid1400,99es_ES
upv.uuid320fc6b0-16d2-49c3-8fe2-a32e26c82a57es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
VrakaMoreno-ArribasGracia-Baena - The Relevance of Heart Rate Fluctuation When Evaluating Atrial ....pdf
Tamaño:
1.2 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial