In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluids

dc.contributor.authorIgual Muñoz, Anna Neuses_ES
dc.contributor.authorSchwiesau, J.es_ES
dc.contributor.authorJolles, B. M.es_ES
dc.contributor.authorMischler, Stefanoes_ES
dc.date.accessioned2016-10-17T08:56:45Z
dc.date.available2016-10-17T08:56:45Z
dc.date.issued2015-07-15
dc.description.abstractThe present study was initiated with the aim to assess the in vivo electrochemical corrosion behaviour of CoCrMo biomedical alloys in human synovial fluids in an attempt to identify possible patient or pathology specific effects. For this, electrochemical measurements (open circuit potential OCP, polarization resistance R-p, potentiodynamic polarization curves, electrochemical impedance spectroscopy EIS) were carried out on fluids extracted from patients with different articular pathologies and prosthesis revisions. Those electrochemical measurements could be carried out with outstanding precision and signal stability. The results show that the corrosion behaviour of CoCrMo alloy in synovial fluids not only depends on material reactivity but also on the specific reactions of synovial fluid components, most likely involving reactive oxygen species. In some patients the latter were found to determine the whole cathodic and anodic electrochemical response. Depending on patients, corrosion rates varied significantly between 50 and 750 mg dm(-2) year(-1).es_ES
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationIgual Muñoz, AN.; Schwiesau, J.; Jolles, BM.; Mischler, S. (2015). In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluids. Acta Biomaterialia. 21:228-236. doi:10.1016/j.actbio.2015.03.008es_ES
dc.description.upvformatpfin236es_ES
dc.description.upvformatpinicio228es_ES
dc.description.volume21es_ES
dc.identifier.doi10.1016/j.actbio.2015.03.008
dc.identifier.eissn1878-7568
dc.identifier.issn1742-7061
dc.identifier.urihttps://riunet.upv.es/handle/10251/71895
dc.languageIngléses_ES
dc.publisherElsevieres_ES
dc.relation.ispartofActa Biomaterialiaes_ES
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.actbio.2015.03.008es_ES
dc.relation.senia304174es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsCerradoes_ES
dc.subjectHuman synoviaes_ES
dc.subjectCorrosiones_ES
dc.subjectElectrochemistryes_ES
dc.subjectCoCrMo alloyes_ES
dc.subjectKnee implantses_ES
dc.subject.classificationINGENIERIA QUIMICAes_ES
dc.titleIn vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluidses_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuid3f7ed40a-fd28-4bcd-86bf-7ad4e81c1a38es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Igual;STEFANO MISCHLER - In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in ....pdf
Tamaño:
2.71 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial