First Compton telescope prototype based on continuous LaBr3-SiPM detectors
| dc.contributor.affiliation | Departamento de Ingeniería Electrónica | |
| dc.contributor.affiliation | Escuela Técnica Superior de Ingeniería de Telecomunicación | |
| dc.contributor.author | Llosá, G. | es_ES |
| dc.contributor.author | Cabello, J. | es_ES |
| dc.contributor.author | Callier, S. | es_ES |
| dc.contributor.author | Gillam, J.E. | es_ES |
| dc.contributor.author | Lacasta, C. | es_ES |
| dc.contributor.author | Rafecas, M. | es_ES |
| dc.contributor.author | Raux, L. | es_ES |
| dc.contributor.author | Solaz, C. | es_ES |
| dc.contributor.author | Stankova, V. | es_ES |
| dc.contributor.author | de la Taille, C. | es_ES |
| dc.contributor.author | Trovato, M. | es_ES |
| dc.contributor.author | Barrio-Toala, John | |
| dc.contributor.funder | European Commission | es_ES |
| dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |
| dc.date.accessioned | 2026-02-23T11:07:05Z | |
| dc.date.available | 2026-02-23T11:07:05Z | |
| dc.date.issued | 2013-08-01 | es_ES |
| dc.description.abstract | [EN] A first prototype of a Compton camera based on continuous scintillator crystals coupled to silicon photomultiplier (SiPM) arrays has been successfully developed and operated. The prototype is made of two detector planes. The first detector is made of a continuous 16 x 18 x 5 mm(3) LaBr3 crystal coupled to a 16-elements SiPM array. The elements have a size of 3 x 3 mm (3) in a 4.5 x 4.05 mm(2) pitch. The second detector, selected by availability, consists of a continuous 16 x 18 x 5 mm(3) LYSO crystal coupled to a similar SiPM array. The SPIROC1 ASIC is employed in the readout electronics. Data have been taken with a Na-22 source placed at different positions and images have been reconstructed with the simulated one-pass list-mode (SOPL) algorithm. Detector development for the construction of a second prototype with three detector planes is underway. LaBr3 crystals of 32 x 36 mm(2) size and 5/10 mm thickness have been acquired and tested with a PMT. The resolution obtained is 3.5% FWHM at 511 keV. Each crystal will be coupled to four MPPC arrays. Different options are being tested for the prototype readout. | en_EN |
| dc.description.accrualMethod | S | es_ES |
| dc.description.bibliographicCitation | Llosá, G.; Cabello, J.; Callier, S.; Gillam, J.; Lacasta, C.; Rafecas, M.; Raux, L.... (2013). First Compton telescope prototype based on continuous LaBr3-SiPM detectors. Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment. 718:130-133. https://doi.org/10.1016/j.nima.2012.08.074 | es_ES |
| dc.description.references | D. Dauvergne, M. Battaglia, G. Montarou, E. Testa, New methods of real-time control imaging for ion therapy. NIRS-ETOILE Joint Symposium on Carbon Ion Therapy, Lyon (France), 2009. | es_ES |
| dc.description.references | Kormoll, T., Fiedler, F., Schöne, S., Wüstemann, J., Zuber, K., & Enghardt, W. (2011). A Compton imager for in-vivo dosimetry of proton beams—A design study. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 626-627, 114-119. https://doi.org/10.1016/j.nima.2010.10.031 | es_ES |
| dc.description.references | G. Llosá, et al., Detector characterization and first coincidence tests of a Compton telescope based on LaBr3 crystals and SiPMs, Nuclear Instruments and Methods in Physics Research Section A, 10.1016/j.nima.2011.11.041, in press. | es_ES |
| dc.description.references | M. Bouchel, et al., SPIROC (SiPM Integrated Read-Out Chip): Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out, 2007 NSS MIC Conference Record, 2007, pp. 1857–1860. | es_ES |
| dc.description.references | J. Cabello, J. Barrio, C. Lacasta, M. Rafecas y G. Llosá, Position Reconstruction in Detectors Based on Continuous Crystals Coupled to Silicon Photomultiplier Arrays, IEEE NSS MIC Conference Record, pp. 3911–3916. | es_ES |
| dc.description.references | J. Gillam, et al., Simulated One-Pass List-Mode: A Highly Flexible Method of Image Reconstruction for PET 2011 IEEE NSS MIC Conference Record, pp. 4206–4210. | es_ES |
| dc.description.references | V. Stankova, et al., Data Acquisition System for the Readout of SiPM Matrix with the VATA64HDR16 Front-End ASIC, 2011 IEEE NSS MIC Conference Record, pp. 807–809. | es_ES |
| dc.description.sponsorship | This work was supported in part by the ENVISION project (Grant Agreement num 241851), and ENTERVISION ITN (Grant Agreement num 264552), funded by the European Commission under FP7, and through a Research project of the Spanish Ministerio de Economia y Competitividad/Plan Nacional de IþDþi (FPA2010-14891). Several group members are supported through the Juan de la Cierva (CSIC), JAE-DOC (CSIC) and Atraccio de Talent (UV) programs. | es_ES |
| dc.description.upvformatpfin | 133 | es_ES |
| dc.description.upvformatpinicio | 130 | es_ES |
| dc.description.volume | 718 | es_ES |
| dc.identifier.doi | 10.1016/j.nima.2012.08.074 | es_ES |
| dc.identifier.issn | 0168-9002 | es_ES |
| dc.identifier.uri | https://riunet.upv.es/handle/10251/232858 | |
| dc.language | Inglés | es_ES |
| dc.publisher | Elsevier | es_ES |
| dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment | es_ES |
| dc.relation.pasarela | S\574407 | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/EC/FP7/241851/EU/European NoVel Imaging Systems for ION therapy/ | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/EC/FP7/264552/EU | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//FPA2010-14891/ | es_ES |
| dc.relation.publisherversion | https://doi.org/10.1016/j.nima.2012.08.074 | es_ES |
| dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
| dc.rights.accessRights | Abierto | es_ES |
| dc.subject | LaBr3 | es_ES |
| dc.subject | MG-APD | es_ES |
| dc.subject | SiPM | es_ES |
| dc.subject | Compton imaging | es_ES |
| dc.subject | Hadron therapy | es_ES |
| dc.title | First Compton telescope prototype based on continuous LaBr3-SiPM detectors | es_ES |
| dc.type | Artículo | es_ES |
| dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
| dspace.entity.type | Publication | es_ES |
| person.identifier | 292970 | |
| person.identifier.orcid | 0000-0001-5181-2146 | |
| relation.isAuthorOfPublication | ff8abe35-aa35-4d83-982a-647cbb7dca2c | |
| relation.isAuthorOfPublication.latestForDiscovery | ff8abe35-aa35-4d83-982a-647cbb7dca2c | |
| relation.isOrgUnitOfPublication | a3ca7df3-e467-4f69-b673-79a5d6241220 | |
| relation.isOrgUnitOfPublication | aa6a0db9-4584-45eb-b7e3-73606ac49444 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | a3ca7df3-e467-4f69-b673-79a5d6241220 | |
| upv.uuid | 5ef0b9ab-3c6e-41b5-9ec7-38d21a5dedb0 | es_ES |
Archivos
Bloque original
1 - 2 de 2
Cargando...
- Nombre:
- 2013_NIM_2_autor.pdf
- Tamaño:
- 946.95 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Versión del Autor
Cargando...
- Nombre:
- LlosaCabelloCallier - First Compton telescope prototype based on continuous LaBr3-SiPM detectors.pdf
- Tamaño:
- 892.83 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Versión editorial