Effect of SMA bar-friction damper series device on hysteretic performance of steel semi-rigid and hinged joints

dc.contributor.affiliationDepartamento de Construcciones Arquitectónicas
dc.contributor.affiliationEscuela Técnica Superior de Ingeniería de Edificación
dc.contributor.affiliationCentro de Investigación de Tecnología de la Edificación
dc.contributor.authorQi, Liangjiees_ES
dc.contributor.authorDing, Mengfeies_ES
dc.contributor.authorYuan, Zhenes_ES
dc.contributor.authorXue, Gaominges_ES
dc.contributor.authorAlbiol Ibáñez, José Ramón
dc.contributor.funderNational Natural Science Foundation of Chinaes_ES
dc.contributor.funderKey Research and Development Projects of Shaanxi Provincees_ES
dc.date.accessioned2026-01-07T06:41:33Z
dc.date.available2026-01-07T06:41:33Z
dc.date.issued2025-06-10es_ES
dc.description.abstract[EN] The extensive application of steel material in Chinese archaized buildings not only represents the unique exterior appearance of traditional architecture but also effectively addresses issues such as the susceptibility to decay and deformation in wooden structures. However, conventional rigid beam-column welded connections in steel archaized buildings are prone to premature rupture under seismic events. To further enhance the energy dissipation capacity and post-earthquake repairability of beam-column joints in steel archaized buildings, this paper proposes a self-centering energy dissipation device composed of shape memory alloy (SMA) bars and friction dampers connected in series. Four full-scale joint specimens with different joint stiffnesses were designed and subjected to low-cycle repeated loading tests. The results indicated that the combination of semirigid beam-column joints and self-centering energy dissipation devices using shear-type friction dampers exhibit stronger energy dissipation and load-bearing capacities with minimal residual deformation compared to other configurations. Based on experimental results, a three-dimensional numerical model was established using ABAQUS finite element software to investigate the effects of beam end-plate thickness and the length of weak zone in the extended limb length in angle steels on the mechanical performance, energy dissipation capacity, residual deformation, and self-centering performance of beam-column joints in steel archaized buildings equipped with SMA bar-friction damper series devices. Finally, design recommendations were provided for the end-plate of the beam and the replaceable angle steel at the beam-column joints in steel archaized buildings.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationQi, L.; Ding, M.; Yuan, Z.; Xue, G.; Albiol Ibáñez, José Ramón (2025). Effect of SMA bar-friction damper series device on hysteretic performance of steel semi-rigid and hinged joints. Steel and Composite Structures. 55(5):365-381. https://doi.org/10.12989/scs.2025.55.5.365es_ES
dc.description.issue5es_ES
dc.description.sponsorshipThis research is supported by the National Natural Science Foundation of China (Grant No. 52008330) , and the Key Scientific Research Project of the Education Department of Shaanxi Provincial Government (Grant No. 22JY030) .es_ES
dc.description.upvformatpfin381es_ES
dc.description.upvformatpinicio365es_ES
dc.description.volume55es_ES
dc.identifier.doi10.12989/scs.2025.55.5.365es_ES
dc.identifier.issn1229-9367es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/231362
dc.languageIngléses_ES
dc.publisherTechno-Presses_ES
dc.relation.ispartofSteel and Composite Structureses_ES
dc.relation.pasarelaS\556279es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/NSFC//52008330/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/Key Research and Development Projects of Shaanxi Province//22JY030/es_ES
dc.relation.publisherversionhttps://doi.org/10.12989/scs.2025.55.5.365es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsCerradoes_ES
dc.subjectReplaceabilityes_ES
dc.subjectSemi-rigid beam-column jointes_ES
dc.subjectSMA bar-friction damper series devicees_ES
dc.subjectSteel archaized buildinges_ES
dc.subject.ods11.- Conseguir que las ciudades y los asentamientos humanos sean inclusivos, seguros, resilientes y sostenibleses_ES
dc.titleEffect of SMA bar-friction damper series device on hysteretic performance of steel semi-rigid and hinged jointses_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublicationes_ES
person.identifier33707
person.identifier.orcid0000-0003-3049-9693
relation.isAuthorOfPublicatione5fcaa84-57db-4bb5-a6c2-78c0d35b1589
relation.isAuthorOfPublication.latestForDiscoverye5fcaa84-57db-4bb5-a6c2-78c0d35b1589
relation.isOrgUnitOfPublication74535f31-c7e4-4498-94d8-d383211eb09b
relation.isOrgUnitOfPublicationde470012-4694-43ee-87f9-6cafbd5e0f95
relation.isOrgUnitOfPublication2b10555d-ef13-46a0-845e-77b9c48aeb40
relation.isOrgUnitOfPublication.latestForDiscovery74535f31-c7e4-4498-94d8-d383211eb09b
upv.uuid7465ebd7-abfa-4d33-a709-1512e332d826es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
QiDingYuan - Effect of SMA bar-friction damper series device on hysteretic performance of steel s....pdf
Tamaño:
6.61 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial