Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices
| dc.contributor.affiliation | Departamento de Ingeniería Electrónica | |
| dc.contributor.affiliation | Escuela Técnica Superior de Ingeniería de Telecomunicación | |
| dc.contributor.author | Llosá, G. | es_ES |
| dc.contributor.author | Barrio-Toala, John | |
| dc.contributor.author | Lacasta, C. | es_ES |
| dc.contributor.author | Bisogni, M. G. | es_ES |
| dc.contributor.author | Del Guerra, A. | es_ES |
| dc.contributor.author | Marcatili, S. | es_ES |
| dc.contributor.author | Barrillon, P. | es_ES |
| dc.contributor.author | Bondil-Blin, S. | es_ES |
| dc.contributor.author | de la Taille, C. | es_ES |
| dc.contributor.author | Piemonte, C. | es_ES |
| dc.contributor.funder | European Commission | es_ES |
| dc.date.accessioned | 2026-02-23T11:03:49Z | |
| dc.date.available | 2026-02-23T11:03:49Z | |
| dc.date.issued | 2010-12-07 | es_ES |
| dc.description.abstract | [EN] The characterization of a PET detector head based on continuous LYSO crystals and silicon photomultiplier (SiPM) arrays as photodetectors has been carried out for its use in the development of a small animal PET prototype. The detector heads are composed of a continuous crystal and a SiPM matrix with 64 pixels in a common substrate, fabricated specifically for this project. Three crystals of 12 mm x 12 mm x 5 mm size with different types of painting have been tested: white, black and black on the sides but white on the back of the crystal. The best energy resolution, obtained with the white crystal, is 16% FWHM. The detector response is linear up to 1275 keV. Tests with different position determination algorithms have been carried out with the three crystals. The spatial resolution obtained with the center of gravity algorithm is around 0.9 mm FWHM for the three crystals. As expected, the use of this algorithm results in the displacement of the reconstructed position toward the center of the crystal, more pronounced in the case of the white crystal. A maximum likelihood algorithm has been tested that can reconstruct correctly the interaction position of the photons also in the case of the white crystal. | en_EN |
| dc.description.accrualMethod | S | es_ES |
| dc.description.bibliographicCitation | Llosá, G.; Barrio-Toala, John; Lacasta, C.; Bisogni, MG.; Del Guerra, A.; Marcatili, S.; Barrillon, P.... (2010). Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices. Physics in Medicine and Biology. 55(23):7299-7315. https://doi.org/10.1088/0031-9155/55/23/008 | es_ES |
| dc.description.issue | 23 | es_ES |
| dc.description.references | Anger, H. O. (1958). Scintillation Camera. Review of Scientific Instruments, 29(1), 27-33. https://doi.org/10.1063/1.1715998 | es_ES |
| dc.description.references | Bruyndonckx, P., Lemaitre, C., van der Laan, D. J., Maas, M., Schaart, D., Yonggang, W., Li, Z., Krieguer, M., & Tavernier, S. (2008). Evaluation of Machine Learning Algorithms for Localization of Photons in Undivided Scintillator Blocks for PET Detectors. IEEE Transactions on Nuclear Science, 55(3), 918-924. https://doi.org/10.1109/tns.2008.922811 | es_ES |
| dc.description.references | Bruyndonckx, P., Leonard, S., Lemaitre, C., Tavernier, S., & Wu, Y. (2006). Performance Study of a PET Detector Module Based on a Continuous Scintillator. IEEE Transactions on Nuclear Science, 53(5), 2536-2542. https://doi.org/10.1109/tns.2006.882799 | es_ES |
| dc.description.references | España, S., Fraile, L. M., Herraiz, J. L., Udías, J. M., Desco, M., & Vaquero, J. J. (2010). Performance evaluation of SiPM photodetectors for PET imaging in the presence of magnetic fields. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 613(2), 308-316. https://doi.org/10.1016/j.nima.2009.11.066 | es_ES |
| dc.description.references | Fessler, J. A., Rogers, W. L., & Clinthorne, N. H. (s. f.). Robust maximum-likelihood position estimation in scintillation cameras. Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference, 1851-1855. https://doi.org/10.1109/nssmic.1991.259236 | es_ES |
| dc.description.references | Golovin, V., & Saveliev, V. (2004). Novel type of avalanche photodetector with Geiger mode operation. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 518(1-2), 560-564. https://doi.org/10.1016/j.nima.2003.11.085 | es_ES |
| dc.description.references | Gray, R. M., & Macovski, A. (1976). Maximum a Posteriori Estimation of Position in Scintillation Cameras. IEEE Transactions on Nuclear Science, 23(1), 849-852. https://doi.org/10.1109/tns.1976.4328354 | es_ES |
| dc.description.references | Joung, J., Miyaoka, R. S., & Lewellen, T. K. (2002). cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 489(1-3), 584-598. https://doi.org/10.1016/s0168-9002(02)00861-6 | es_ES |
| dc.description.references | Kolb, A., Lorenz, E., Judenhofer, M. S., Renker, D., Lankes, K., & Pichler, B. J. (2010). Evaluation of Geiger-mode APDs for PET block detector designs. Physics in Medicine and Biology, 55(7), 1815-1832. https://doi.org/10.1088/0031-9155/55/7/003 | es_ES |
| dc.description.references | Lewellen, T. K. (2008). Recent developments in PET detector technology. Physics in Medicine and Biology, 53(17), R287-R317. https://doi.org/10.1088/0031-9155/53/17/r01 | es_ES |
| dc.description.references | Llosa, G., Belcari, N., Bisogni, M. G., Collazuol, G., Marcatili, S., Barrillon, P., de la Taille, C., Bondil-Blin, S., Dinu, N., Melchiorri, M., Tarolli, A., Piemonte, C., & Del Guerra, A. (2009). Energy, Timing and Position Resolution Studies With 16-Pixel Silicon Photomultiplier Matrices for Small Animal PET. IEEE Transactions on Nuclear Science, 56(5), 2586-2593. https://doi.org/10.1109/tns.2009.2030191 | es_ES |
| dc.description.references | McElroy, D. P., Saveliev, V., Reznik, A., & Rowlands, J. A. (2007). Evaluation of silicon photomultipliers: A promising new detector for MR compatible PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 571(1-2), 106-109. https://doi.org/10.1016/j.nima.2006.10.040 | es_ES |
| dc.description.references | Moehrs, S., Guerra, A. D., Herbert, D. J., & Mandelkern, M. A. (2006). A detector head design for small-animal PET with silicon photomultipliers (SiPM). Physics in Medicine and Biology, 51(5), 1113-1127. https://doi.org/10.1088/0031-9155/51/5/004 | es_ES |
| dc.description.references | Pani, R., Vittorini, F., Pellegrini, R., Bennati, P., Cinti, M. N., Mattioli, M., Scafe, R., Lo Meo, S., Navarria, F., Moschini, G., Boccaccio, P., Cencelli, V. O., & De Notaristefani, F. (2008). High spatial and energy resolution gamma imaging based on LaBr3(Ce) continuous crystals. 2008 IEEE Nuclear Science Symposium Conference Record, 1763-1771. https://doi.org/10.1109/nssmic.2008.4775116 | es_ES |
| dc.description.references | Piemonte, C. (2006). A new Silicon Photomultiplier structure for blue light detection. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 568(1), 224-232. https://doi.org/10.1016/j.nima.2006.07.018 | es_ES |
| dc.description.references | Post, R. F., & Schiff, L. I. (1950). Statistical Limitations on the Resolving Time of a Scintillation Counter. Physical Review, 80(6), 1113-1113. https://doi.org/10.1103/physrev.80.1113 | es_ES |
| dc.description.references | Renker, D. (2006). Geiger-mode avalanche photodiodes, history, properties and problems. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 567(1), 48-56. https://doi.org/10.1016/j.nima.2006.05.060 | es_ES |
| dc.description.references | Schaart, D. R., van Dam, H. T., Seifert, S., Vinke, R., Dendooven, P., Löhner, H., & Beekman, F. J. (2009). A novel, SiPM-array-based, monolithic scintillator detector for PET. Physics in Medicine and Biology, 54(11), 3501-3512. https://doi.org/10.1088/0031-9155/54/11/015 | es_ES |
| dc.description.references | Hodler, J., von Schulthess, G. K., Zollikofer, C. L., & Matamoros, A. (2007). Diseases of the Heart, Chest and Breast: Diagnostic Imaging and Interventional Techniques. Journal of Nuclear Medicine, 49(1), 165-165. https://doi.org/10.2967/jnumed.107.045609 | es_ES |
| dc.description.references | Vinke, R., Löhner, H., Schaart, D. R., van Dam, H. T., Seifert, S., Beekman, F. J., & Dendooven, P. (2009). Optimizing the timing resolution of SiPM sensors for use in TOF-PET detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 610(1), 188-191. https://doi.org/10.1016/j.nima.2009.05.068 | es_ES |
| dc.description.sponsorship | This work is partially supported by the European Commission's Seventh Framework Programme through a Marie Curie Reintegration Grant. | es_ES |
| dc.description.upvformatpfin | 7315 | es_ES |
| dc.description.upvformatpinicio | 7299 | es_ES |
| dc.description.volume | 55 | es_ES |
| dc.identifier.doi | 10.1088/0031-9155/55/23/008 | es_ES |
| dc.identifier.issn | 0031-9155 | es_ES |
| dc.identifier.uri | https://riunet.upv.es/handle/10251/232838 | |
| dc.language | Inglés | es_ES |
| dc.publisher | IOP Publishing | es_ES |
| dc.relation.ispartof | Physics in Medicine and Biology | es_ES |
| dc.relation.pasarela | S\574393 | es_ES |
| dc.relation.publisherversion | https://doi.org/10.1088/0031-9155/55/23/008 | es_ES |
| dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
| dc.rights.accessRights | Abierto | es_ES |
| dc.subject | Positron emission tomography | es_ES |
| dc.subject | LYSO crystals | es_ES |
| dc.subject | Silicon photomultipliers | es_ES |
| dc.subject | Small animal PET | es_ES |
| dc.subject | Spatial resolution | es_ES |
| dc.subject | Position reconstruction | es_ES |
| dc.title | Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices | es_ES |
| dc.type | Artículo | es_ES |
| dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
| dspace.entity.type | Publication | es_ES |
| person.identifier | 292970 | |
| person.identifier.orcid | 0000-0001-5181-2146 | |
| relation.isAuthorOfPublication | ff8abe35-aa35-4d83-982a-647cbb7dca2c | |
| relation.isAuthorOfPublication.latestForDiscovery | ff8abe35-aa35-4d83-982a-647cbb7dca2c | |
| relation.isOrgUnitOfPublication | a3ca7df3-e467-4f69-b673-79a5d6241220 | |
| relation.isOrgUnitOfPublication | aa6a0db9-4584-45eb-b7e3-73606ac49444 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | a3ca7df3-e467-4f69-b673-79a5d6241220 | |
| upv.uuid | 7e7e9318-1c74-43b0-9b68-0649a04d3dd8 | es_ES |
Archivos
Bloque original
1 - 2 de 2
Cargando...
- Nombre:
- LlosaBarrio-ToalaLacasta - Characterization of a PET detector head based on continuous LYSO cryst....pdf
- Tamaño:
- 1.51 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Versión del Autor
Cargando...
- Nombre:
- 2010_PMB.pdf
- Tamaño:
- 1.62 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Versión editorial