Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices

dc.contributor.affiliationDepartamento de Ingeniería Electrónica
dc.contributor.affiliationEscuela Técnica Superior de Ingeniería de Telecomunicación
dc.contributor.authorLlosá, G.es_ES
dc.contributor.authorBarrio-Toala, John
dc.contributor.authorLacasta, C.es_ES
dc.contributor.authorBisogni, M. G.es_ES
dc.contributor.authorDel Guerra, A.es_ES
dc.contributor.authorMarcatili, S.es_ES
dc.contributor.authorBarrillon, P.es_ES
dc.contributor.authorBondil-Blin, S.es_ES
dc.contributor.authorde la Taille, C.es_ES
dc.contributor.authorPiemonte, C.es_ES
dc.contributor.funderEuropean Commissiones_ES
dc.date.accessioned2026-02-23T11:03:49Z
dc.date.available2026-02-23T11:03:49Z
dc.date.issued2010-12-07es_ES
dc.description.abstract[EN] The characterization of a PET detector head based on continuous LYSO crystals and silicon photomultiplier (SiPM) arrays as photodetectors has been carried out for its use in the development of a small animal PET prototype. The detector heads are composed of a continuous crystal and a SiPM matrix with 64 pixels in a common substrate, fabricated specifically for this project. Three crystals of 12 mm x 12 mm x 5 mm size with different types of painting have been tested: white, black and black on the sides but white on the back of the crystal. The best energy resolution, obtained with the white crystal, is 16% FWHM. The detector response is linear up to 1275 keV. Tests with different position determination algorithms have been carried out with the three crystals. The spatial resolution obtained with the center of gravity algorithm is around 0.9 mm FWHM for the three crystals. As expected, the use of this algorithm results in the displacement of the reconstructed position toward the center of the crystal, more pronounced in the case of the white crystal. A maximum likelihood algorithm has been tested that can reconstruct correctly the interaction position of the photons also in the case of the white crystal.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationLlosá, G.; Barrio-Toala, John; Lacasta, C.; Bisogni, MG.; Del Guerra, A.; Marcatili, S.; Barrillon, P.... (2010). Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices. Physics in Medicine and Biology. 55(23):7299-7315. https://doi.org/10.1088/0031-9155/55/23/008es_ES
dc.description.issue23es_ES
dc.description.referencesAnger, H. O. (1958). Scintillation Camera. Review of Scientific Instruments, 29(1), 27-33. https://doi.org/10.1063/1.1715998es_ES
dc.description.referencesBruyndonckx, P., Lemaitre, C., van der Laan, D. J., Maas, M., Schaart, D., Yonggang, W., Li, Z., Krieguer, M., & Tavernier, S. (2008). Evaluation of Machine Learning Algorithms for Localization of Photons in Undivided Scintillator Blocks for PET Detectors. IEEE Transactions on Nuclear Science, 55(3), 918-924. https://doi.org/10.1109/tns.2008.922811es_ES
dc.description.referencesBruyndonckx, P., Leonard, S., Lemaitre, C., Tavernier, S., & Wu, Y. (2006). Performance Study of a PET Detector Module Based on a Continuous Scintillator. IEEE Transactions on Nuclear Science, 53(5), 2536-2542. https://doi.org/10.1109/tns.2006.882799es_ES
dc.description.referencesEspaña, S., Fraile, L. M., Herraiz, J. L., Udías, J. M., Desco, M., & Vaquero, J. J. (2010). Performance evaluation of SiPM photodetectors for PET imaging in the presence of magnetic fields. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 613(2), 308-316. https://doi.org/10.1016/j.nima.2009.11.066es_ES
dc.description.referencesFessler, J. A., Rogers, W. L., & Clinthorne, N. H. (s. f.). Robust maximum-likelihood position estimation in scintillation cameras. Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference, 1851-1855. https://doi.org/10.1109/nssmic.1991.259236es_ES
dc.description.referencesGolovin, V., & Saveliev, V. (2004). Novel type of avalanche photodetector with Geiger mode operation. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 518(1-2), 560-564. https://doi.org/10.1016/j.nima.2003.11.085es_ES
dc.description.referencesGray, R. M., & Macovski, A. (1976). Maximum a Posteriori Estimation of Position in Scintillation Cameras. IEEE Transactions on Nuclear Science, 23(1), 849-852. https://doi.org/10.1109/tns.1976.4328354es_ES
dc.description.referencesJoung, J., Miyaoka, R. S., & Lewellen, T. K. (2002). cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 489(1-3), 584-598. https://doi.org/10.1016/s0168-9002(02)00861-6es_ES
dc.description.referencesKolb, A., Lorenz, E., Judenhofer, M. S., Renker, D., Lankes, K., & Pichler, B. J. (2010). Evaluation of Geiger-mode APDs for PET block detector designs. Physics in Medicine and Biology, 55(7), 1815-1832. https://doi.org/10.1088/0031-9155/55/7/003es_ES
dc.description.referencesLewellen, T. K. (2008). Recent developments in PET detector technology. Physics in Medicine and Biology, 53(17), R287-R317. https://doi.org/10.1088/0031-9155/53/17/r01es_ES
dc.description.referencesLlosa, G., Belcari, N., Bisogni, M. G., Collazuol, G., Marcatili, S., Barrillon, P., de la Taille, C., Bondil-Blin, S., Dinu, N., Melchiorri, M., Tarolli, A., Piemonte, C., & Del Guerra, A. (2009). Energy, Timing and Position Resolution Studies With 16-Pixel Silicon Photomultiplier Matrices for Small Animal PET. IEEE Transactions on Nuclear Science, 56(5), 2586-2593. https://doi.org/10.1109/tns.2009.2030191es_ES
dc.description.referencesMcElroy, D. P., Saveliev, V., Reznik, A., & Rowlands, J. A. (2007). Evaluation of silicon photomultipliers: A promising new detector for MR compatible PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 571(1-2), 106-109. https://doi.org/10.1016/j.nima.2006.10.040es_ES
dc.description.referencesMoehrs, S., Guerra, A. D., Herbert, D. J., & Mandelkern, M. A. (2006). A detector head design for small-animal PET with silicon photomultipliers (SiPM). Physics in Medicine and Biology, 51(5), 1113-1127. https://doi.org/10.1088/0031-9155/51/5/004es_ES
dc.description.referencesPani, R., Vittorini, F., Pellegrini, R., Bennati, P., Cinti, M. N., Mattioli, M., Scafe, R., Lo Meo, S., Navarria, F., Moschini, G., Boccaccio, P., Cencelli, V. O., & De Notaristefani, F. (2008). High spatial and energy resolution gamma imaging based on LaBr3(Ce) continuous crystals. 2008 IEEE Nuclear Science Symposium Conference Record, 1763-1771. https://doi.org/10.1109/nssmic.2008.4775116es_ES
dc.description.referencesPiemonte, C. (2006). A new Silicon Photomultiplier structure for blue light detection. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 568(1), 224-232. https://doi.org/10.1016/j.nima.2006.07.018es_ES
dc.description.referencesPost, R. F., & Schiff, L. I. (1950). Statistical Limitations on the Resolving Time of a Scintillation Counter. Physical Review, 80(6), 1113-1113. https://doi.org/10.1103/physrev.80.1113es_ES
dc.description.referencesRenker, D. (2006). Geiger-mode avalanche photodiodes, history, properties and problems. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 567(1), 48-56. https://doi.org/10.1016/j.nima.2006.05.060es_ES
dc.description.referencesSchaart, D. R., van Dam, H. T., Seifert, S., Vinke, R., Dendooven, P., Löhner, H., & Beekman, F. J. (2009). A novel, SiPM-array-based, monolithic scintillator detector for PET. Physics in Medicine and Biology, 54(11), 3501-3512. https://doi.org/10.1088/0031-9155/54/11/015es_ES
dc.description.referencesHodler, J., von Schulthess, G. K., Zollikofer, C. L., & Matamoros, A. (2007). Diseases of the Heart, Chest and Breast: Diagnostic Imaging and Interventional Techniques. Journal of Nuclear Medicine, 49(1), 165-165. https://doi.org/10.2967/jnumed.107.045609es_ES
dc.description.referencesVinke, R., Löhner, H., Schaart, D. R., van Dam, H. T., Seifert, S., Beekman, F. J., & Dendooven, P. (2009). Optimizing the timing resolution of SiPM sensors for use in TOF-PET detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 610(1), 188-191. https://doi.org/10.1016/j.nima.2009.05.068es_ES
dc.description.sponsorshipThis work is partially supported by the European Commission's Seventh Framework Programme through a Marie Curie Reintegration Grant.es_ES
dc.description.upvformatpfin7315es_ES
dc.description.upvformatpinicio7299es_ES
dc.description.volume55es_ES
dc.identifier.doi10.1088/0031-9155/55/23/008es_ES
dc.identifier.issn0031-9155es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/232838
dc.languageIngléses_ES
dc.publisherIOP Publishinges_ES
dc.relation.ispartofPhysics in Medicine and Biologyes_ES
dc.relation.pasarelaS\574393es_ES
dc.relation.publisherversionhttps://doi.org/10.1088/0031-9155/55/23/008es_ES
dc.rightsReconocimiento - No comercial - Sin obra derivada (by-nc-nd)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectPositron emission tomographyes_ES
dc.subjectLYSO crystalses_ES
dc.subjectSilicon photomultiplierses_ES
dc.subjectSmall animal PETes_ES
dc.subjectSpatial resolutiones_ES
dc.subjectPosition reconstructiones_ES
dc.titleCharacterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matriceses_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublicationes_ES
person.identifier292970
person.identifier.orcid0000-0001-5181-2146
relation.isAuthorOfPublicationff8abe35-aa35-4d83-982a-647cbb7dca2c
relation.isAuthorOfPublication.latestForDiscoveryff8abe35-aa35-4d83-982a-647cbb7dca2c
relation.isOrgUnitOfPublicationa3ca7df3-e467-4f69-b673-79a5d6241220
relation.isOrgUnitOfPublicationaa6a0db9-4584-45eb-b7e3-73606ac49444
relation.isOrgUnitOfPublication.latestForDiscoverya3ca7df3-e467-4f69-b673-79a5d6241220
upv.uuid7e7e9318-1c74-43b0-9b68-0649a04d3dd8es_ES

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
LlosaBarrio-ToalaLacasta - Characterization of a PET detector head based on continuous LYSO cryst....pdf
Tamaño:
1.51 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión del Autor
Cargando...
Miniatura
Nombre:
2010_PMB.pdf
Tamaño:
1.62 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial