Design, establishment, analysis and quality control of a high-precision reference frame in Cortes de Pallás (Spain)

dc.contributor.affiliationDepartamento de Ingeniería Cartográfica Geodesia y Fotogrametría
dc.contributor.affiliationEscuela Técnica Superior de Ingeniería Geodésica, Cartográfica y Topográfica
dc.contributor.affiliationGrupo de Cartografía, Geodesia y GPS
dc.contributor.authorGarcía-Asenjo Villamayor, Luis
dc.contributor.authorMartínez, Lauraes_ES
dc.contributor.authorBaselga Moreno, Sergio
dc.contributor.authorGarrigues, Pascuales_ES
dc.contributor.authorLuján, Raqueles_ES
dc.contributor.funderUniversitat Politècnica de Valènciaes_ES
dc.contributor.funderDiputació de Valènciaes_ES
dc.coverage.spatialeast=-0.9411607; north=39.2418808; name=Camino Nº 2, 1, 46199 Cortes de Pallás, Valencia, Espanyaes_ES
dc.date.accessioned2023-03-06T09:42:59Z
dc.date.available2023-03-06T09:42:59Z
dc.date.issued2023-01-27
dc.description.abstract[EN] A high-precision geodetic reference frame was required in Cortes de Pallás (Spain) to undertake a long-term deformation monitoring project.  Involving distances up to 2000 m, the aimed accuracy was 1 mm and 3 mm for horizontal and vertical components, respectively. Such a high precision is necessary to detect possible displacements of selected points on a critical rocky area in a short period of time, i.e. two or three years, and also to provide ground control for the integration of precise 3D models periodically obtained by remote sensing techniques. Considering the historical geotechnical problems of the area, the possible influence of the hydroelectric power plant, and the peculiar orography of the zone, a proper analysis of the stability is crucial if the reference frame is to be used for rigorous over-time deformation monitoring. This paper describes the deformation monitoring of a 10-pillar geodetic network which was measured from 2018 to 2020 by using a sub-millimetric Mekometer ME5000 (0.2 mm + 0.2 ppm) along with a demanding observing methodology which includes a network of data loggers for temperature, humidity and air pressure as well as proper calibration of sensors and instruments to prevent potential inconsistencies between the scale of the network and the unit of length of the International System (SI-metre). The results demonstrated that the chosen methodology yielded the aimed accuracy. However, using such a high precision methodology entails the problem that small displacements of only one or two millimeters are significantly detected as deformations by conventional deformation analysis and then it arises the problem of finding a subset of stable points for a rigorous datum realization when all the points seem to displace. This general problem is analyzed in the particular case of Cortes de Pallás, where a balanced mix of deformation analysis and technical decisions was eventually adopted to define a precise and stable reference frame for rigorous over-time deformation monitoring.en_EN
dc.description.accrualMethodOCSes_ES
dc.description.bibliographicCitationGarcía-Asenjo, L.; Martínez, L.; Baselga, S.; Garrigues, P.; Luján, R. (2023). Design, establishment, analysis and quality control of a high-precision reference frame in Cortes de Pallás (Spain). En 5th Joint International Symposium on Deformation Monitoring (JISDM 2022). Editorial Universitat Politècnica de València. https://riunet.upv.es/handle/10251/192314es_ES
dc.description.sponsorshipThis work has been carried out under the contract T-726 – Control de deformaciones en la ladera norte de la muela de Cortes de Pallás commissioned by the Diputació de València. The authors are grateful to the UCM which granted the use of its ME5000 Mekometer through a co-operation agreement, to José María Grima for his support to calibrate the ME5000 Mekometer, thermometers, and barometers at the Calibration Laboratory of the UPV. We also acknowledge IGS for their efforts to disseminate products available to the global community, and EURAMET for their contribution to the research efforts on the field of large-scale length metrology for geodesy. The UPV team acknowledge the Programa de Ayudas de Investigación y Desarrollo (PAID-01-20) de la Universitat Politècnica de València for funding the research contract of Raquel Lujánes_ES
dc.description.upvformatpfin224
dc.description.upvformatpinicio223
dc.identifier.isbn9788490489796
dc.identifier.urihttps://riunet.upv.es/handle/10251/192314
dc.languageIngléses_ES
dc.publisherEditorial Universitat Politècnica de Valènciaes_ES
dc.relation.conferencedateJunio 20-22, 2022es_ES
dc.relation.conferencename5th Joint International Symposium on Deformation Monitoringes_ES
dc.relation.conferenceplaceValència, Españaes_ES
dc.relation.ispartof5th Joint International Symposium on Deformation Monitoring (JISDM 2022)
dc.relation.pasarelaOCS\13823es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/Diputació de València//T-726/ES/Control de deformaciones en la ladera norte de la muela de Cortes de Palláses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/UPV//PAID-01-20/es_ES
dc.relation.publisherversionhttp://ocs.editorial.upv.es/index.php/JISDM/JISDM2022/paper/view/13823es_ES
dc.rightsReconocimiento - No comercial - Compartir igual (by-nc-sa)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectGeodetic networkes_ES
dc.subjectReference frameses_ES
dc.subjectDeformation monitoringes_ES
dc.subjectSub-millimetric EDMes_ES
dc.subjectME5000es_ES
dc.subjectLength metrologyes_ES
dc.titleDesign, establishment, analysis and quality control of a high-precision reference frame in Cortes de Pallás (Spain)es_ES
dc.typeCapítulo de libroes_ES
dc.typeComunicación en congresoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
person.identifier2198
person.identifier43287
person.identifier.orcid0000-0001-6535-2216
person.identifier.orcid0000-0002-0492-4003
relation.isAuthorOfPublicationfb03d1d2-1d8d-48b6-9c72-ca9ed7d9d526
relation.isAuthorOfPublication36ae0f1d-e9c5-4bd6-8dc9-2bbcacaf0f10
relation.isAuthorOfPublication.latestForDiscoveryfb03d1d2-1d8d-48b6-9c72-ca9ed7d9d526
relation.isOrgUnitOfPublicationd6948e84-fae2-4b0a-b844-a4930d5b8f47
relation.isOrgUnitOfPublication9d1abfb4-d3a8-4bda-ae58-13f1971682a0
relation.isOrgUnitOfPublication5e5a064d-c6fb-4f43-9107-c574915b0129
relation.isOrgUnitOfPublication.latestForDiscoveryd6948e84-fae2-4b0a-b844-a4930d5b8f47
upv.uuid907d7ccf-dec6-4e81-bfaf-4a40bd3e5619es_ES