Pressure Sensor Placement In Water Networks Based On Sensitivity Matrix: A Real Instrumentation Project Plan

dc.contributor.authorvan Eeckhout, Joanes_ES
dc.contributor.authorCugueró, Josepes_ES
dc.contributor.authorPérez, Ramones_ES
dc.date.accessioned2024-07-11T12:02:32Z
dc.date.available2024-07-11T12:02:32Z
dc.date.issued2024-03-06
dc.description.abstract[EN] The instrumentation and supervision of water distribution networks (WDN) are challenging tasks as the use of monitoring devices imply a high cost including installation and maintenance. One of the emerging issues is the definition of the best possible layout of the measurements to be recorded. Considering the sampling costs and budget limitations on the number of sensors to be distributed, to determine a trade-off is mandatory. The trade-off may highly depend on the final use of these sensors. This work presents a methodology to support practitioners to decide which is the optimal pressure sensor placement and the appropriate number of pressure sensors to install on a WDN. Two main applications for demand calibration and leak detection and localisation are considered. A sensor placement methodology is applied to find the most sensible locations with respect to demand groups. Additionally, as the sensor placement methodology does not define an optimal number of sensors to be distributed in the WDN, an approach to formulate a trade-off is developed. This approach generates an indicator that quantifies the degree of relevance of the information recorded by a given sensor layout. The methodology presented is applied on a real WDN to select the most appropriate pressure measurement layout as part of an instrumentation project plan.en_EN
dc.description.accrualMethodOCSes_ES
dc.description.bibliographicCitationVan Eeckhout, J.; Cugueró, J.; Pérez, R. (2024). Pressure Sensor Placement In Water Networks Based On Sensitivity Matrix: A Real Instrumentation Project Plan. En Editorial Universitat Politècnica de València, Proceedings of the 2nd International Join Conference on Water Distribution System Analysis (WDSA)& Computing and Control in the Water Industry (CCWI) (pp. 844-858). https://doi.org/10.4995/WDSA-CCWI2022.2022.14733es_ES
dc.description.upvformatpfin858
dc.description.upvformatpinicio844
dc.format.extent15es_ES
dc.identifier.doi10.4995/WDSA-CCWI2022.2022.14733
dc.identifier.isbn9788490489826
dc.identifier.urihttps://riunet.upv.es/handle/10251/205980
dc.languageIngléses_ES
dc.publisherEditorial Universitat Politècnica de Valènciaes_ES
dc.relation.conferencedateJulio 18-22, 2022es_ES
dc.relation.conferencename2nd WDSA/CCWI Joint Conferencees_ES
dc.relation.conferenceplaceValencia, Españaes_ES
dc.relation.ispartofProceedings of the 2nd International Join Conference on Water Distribution System Analysis (WDSA)& Computing and Control in the Water Industry (CCWI)es_ES
dc.relation.pasarelaOCS\14733es_ES
dc.relation.publisherversionhttp://ocs.editorial.upv.es/index.php/WDSA-CCWI/WDSA-CCWI2022/paper/view/14733es_ES
dc.rightsReconocimiento - No comercial - Compartir igual (by-nc-sa)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectWater Distribution Networkses_ES
dc.subjectSampling designes_ES
dc.subjectSensorses_ES
dc.titlePressure Sensor Placement In Water Networks Based On Sensitivity Matrix: A Real Instrumentation Project Planes_ES
dc.typeCapítulo de libroes_ES
dc.typeComunicación en congresoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuid9b404cd4-c327-40c8-ac03-ea7c83ab7ff8es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
vanCugueroPerez - Pressure Sensor Placement In Water Networks Based On Sensitivity Matrix A Real ....pdf
Tamaño:
1.65 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial