A Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma Imaging

dc.contributor.affiliationInstituto de Instrumentación para Imagen Molecular
dc.contributor.authorMartins, Paulo Magalhaeses_ES
dc.contributor.authorDal Bello, Riccardoes_ES
dc.contributor.authorSeimetz, Michael
dc.contributor.authorHermann, Germanes_ES
dc.contributor.authorKihm, Thomases_ES
dc.contributor.authorSeco, Joaoes_ES
dc.contributor.funderMax Planck Societyes_ES
dc.contributor.funderAlexander von Humboldt Foundationes_ES
dc.date.accessioned2021-02-13T04:32:13Z
dc.date.available2021-02-13T04:32:13Z
dc.date.issued2020-05-26es_ES
dc.description.abstract[EN] Tracking of single particles accelerated by synchrotrons is a subject that crosses several physics fields. The high clinical intensities used in particle therapy that can exceed 10(9)p/s make this task very challenging. The tracking of the arrival time of single particles in the ion beam is fundamental for the verification of the particle range and dose delivered to the patient. We present a prototype made of scintillating fibers which has been used to provide time-of-flight (TOF) information for three beam species currently accelerated at the Heidelberg Ion-Beam Therapy Center (HIT). We have demonstrated a time-tracker for a prompt-gamma spectroscopy system that allows for a background TOF rejection with a sub-nanosecond time resolution.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationMartins, PM.; Dal Bello, R.; Seimetz, M.; Hermann, G.; Kihm, T.; Seco, J. (2020). A Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma Imaging. Frontiers in Physics. 8:1-13. https://doi.org/10.3389/fphy.2020.00169es_ES
dc.description.referencesParodi, K., Crespo, P., Eickhoff, H., Haberer, T., Pawelke, J., Schardt, D., & Enghardt, W. (2005). Random coincidences during in-beam PET measurements at microbunched therapeutic ion beams. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 545(1-2), 446-458. doi:10.1016/j.nima.2005.02.002es_ES
dc.description.referencesCrespo, P., Barthel, T., Frais-Kolbl, H., Griesmayer, E., Heidel, K., Parodi, K., … Enghardt, W. (2005). Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilities. IEEE Transactions on Nuclear Science, 52(4), 980-987. doi:10.1109/tns.2005.852637es_ES
dc.description.referencesTesta, E., Bajard, M., Chevallier, M., Dauvergne, D., Le Foulher, F., Freud, N., … Testa, M. (2008). Monitoring the Bragg peak location of 73MeV∕u carbon ions by means of prompt γ-ray measurements. Applied Physics Letters, 93(9), 093506. doi:10.1063/1.2975841es_ES
dc.description.referencesBiegun, A. K., Seravalli, E., Lopes, P. C., Rinaldi, I., Pinto, M., Oxley, D. C., … Schaart, D. R. (2012). Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification: a simulation study. Physics in Medicine and Biology, 57(20), 6429-6444. doi:10.1088/0031-9155/57/20/6429es_ES
dc.description.referencesSmeets, J., Roellinghoff, F., Prieels, D., Stichelbaut, F., Benilov, A., Busca, P., … Dubus, A. (2012). Prompt gamma imaging with a slit camera for real-time range control in proton therapy. Physics in Medicine and Biology, 57(11), 3371-3405. doi:10.1088/0031-9155/57/11/3371es_ES
dc.description.referencesVerburg, J. M., Riley, K., Bortfeld, T., & Seco, J. (2013). Energy- and time-resolved detection of prompt gamma-rays for proton range verification. Physics in Medicine and Biology, 58(20), L37-L49. doi:10.1088/0031-9155/58/20/l37es_ES
dc.description.referencesGolnik, C., Hueso-González, F., Müller, A., Dendooven, P., Enghardt, W., Fiedler, F., … Pausch, G. (2014). Range assessment in particle therapy based on promptγ-ray timing measurements. Physics in Medicine and Biology, 59(18), 5399-5422. doi:10.1088/0031-9155/59/18/5399es_ES
dc.description.referencesCambraia Lopes, P., Clementel, E., Crespo, P., Henrotin, S., Huizenga, J., Janssens, G., … Schaart, D. R. (2015). Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters. Physics in Medicine and Biology, 60(15), 6063-6085. doi:10.1088/0031-9155/60/15/6063es_ES
dc.description.referencesPetzoldt, J., Roemer, K. E., Enghardt, W., Fiedler, F., Golnik, C., Hueso-González, F., … Pausch, G. (2016). Characterization of the microbunch time structure of proton pencil beams at a clinical treatment facility. Physics in Medicine and Biology, 61(6), 2432-2456. doi:10.1088/0031-9155/61/6/2432es_ES
dc.description.referencesVerburg, J. M., & Seco, J. (2014). Proton range verification through prompt gamma-ray spectroscopy. Physics in Medicine and Biology, 59(23), 7089-7106. doi:10.1088/0031-9155/59/23/7089es_ES
dc.description.referencesHueso-González, F., Enghardt, W., Fiedler, F., Golnik, C., Janssens, G., Petzoldt, J., … Pausch, G. (2015). First test of the prompt gamma ray timing method with heterogeneous targets at a clinical proton therapy facility. Physics in Medicine and Biology, 60(16), 6247-6272. doi:10.1088/0031-9155/60/16/6247es_ES
dc.description.referencesMartins, P. M., Dal Bello, R., Rinscheid, A., Roemer, K., Werner, T., Enghardt, W., … Seco, J. (2017). Prompt gamma spectroscopy for range control with CeBr3. Current Directions in Biomedical Engineering, 3(2), 113-117. doi:10.1515/cdbme-2017-0023es_ES
dc.description.referencesGil, E. C., Albarrán, E. M., Minucci, E., Nüssle, G., Padolski, S., Petrov, P., … Kozhuharov, V. (2017). The beam and detector of the NA62 experiment at CERN. Journal of Instrumentation, 12(05), P05025-P05025. doi:10.1088/1748-0221/12/05/p05025es_ES
dc.description.referencesSchüttauf, A. (2004). Timing RPCs in FOPI. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 533(1-2), 65-68. doi:10.1016/j.nima.2004.07.002es_ES
dc.description.referencesAlici, A. (2012). Status and performance of the ALICE MRPC-based Time-Of-Flight detector. Journal of Instrumentation, 7(10), P10024-P10024. doi:10.1088/1748-0221/7/10/p10024es_ES
dc.description.referencesBlanco, A., Fonte, P., Garzon, J. A., Koenig, W., Kornakov, G., & Lopes, L. (2013). Performance of the HADES-TOF RPC wall in a Au + Au beam at 1.25 AGeV. Journal of Instrumentation, 8(01), P01004-P01004. doi:10.1088/1748-0221/8/01/p01004es_ES
dc.description.referencesSadrozinski, H. F.-W., Ely, S., Fadeyev, V., Galloway, Z., Ngo, J., Parker, C., … Vinattieri, A. (2013). Ultra-fast silicon detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 730, 226-231. doi:10.1016/j.nima.2013.06.033es_ES
dc.description.referencesCartiglia, N., Staiano, A., Sola, V., Arcidiacono, R., Cirio, R., Cenna, F., … Zavrtanik, M. (2017). Beam test results of a 16 ps timing system based on ultra-fast silicon detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 850, 83-88. doi:10.1016/j.nima.2017.01.021es_ES
dc.description.referencesSadrozinski, H. F.-W., Seiden, A., & Cartiglia, N. (2017). 4D tracking with ultra-fast silicon detectors. Reports on Progress in Physics, 81(2), 026101. doi:10.1088/1361-6633/aa94d3es_ES
dc.description.referencesBeddar, A. S., Mackie, T. R., & Attix, F. H. (1992). Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations. Physics in Medicine and Biology, 37(10), 1883-1900. doi:10.1088/0031-9155/37/10/006es_ES
dc.description.referencesBeddar, A. S., Mackie, T. R., & Attix, F. H. (1992). Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. Physics in Medicine and Biology, 37(10), 1901-1913. doi:10.1088/0031-9155/37/10/007es_ES
dc.description.referencesBeaulieu, L., & Beddar, S. (2016). Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy. Physics in Medicine and Biology, 61(20), R305-R343. doi:10.1088/0031-9155/61/20/r305es_ES
dc.description.referencesBeddar, S., & Beaulieu, L. (Eds.). (2016). Scintillation Dosimetry. Imaging in Medical Diagnosis and Therapy. doi:10.1201/b19491es_ES
dc.description.referencesMarcatili, S., Collot, J., Curtoni, S., Dauvergne, D., Hostachy, J.-Y., Koumeir, C., … Yamouni, M. (2020). Ultra-fast prompt gamma detection in single proton counting regime for range monitoring in particle therapy. Physics in Medicine & Biology, 65(24), 245033. doi:10.1088/1361-6560/ab7a6ces_ES
dc.description.referencesKirn, T. (2017). SciFi – A large scintillating fibre tracker for LHCb. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 845, 481-485. doi:10.1016/j.nima.2016.06.057es_ES
dc.description.referencesLeverington, B. D., Dziewiecki, M., Renner, L., & Runze, R. (2018). A prototype scintillating fibre beam profile monitor for Ion Therapy beams. Journal of Instrumentation, 13(05), P05030-P05030. doi:10.1088/1748-0221/13/05/p05030es_ES
dc.description.referencesVignati, A., Monaco, V., Attili, A., Cartiglia, N., Donetti, M., Mazinani, M. F., … Cirio, R. (2017). Innovative thin silicon detectors for monitoring of therapeutic proton beams: preliminary beam tests. Journal of Instrumentation, 12(12), C12056-C12056. doi:10.1088/1748-0221/12/12/c12056es_ES
dc.description.referencesKrimmer, J., Dauvergne, D., Létang, J. M., & Testa, É. (2018). Prompt-gamma monitoring in hadrontherapy: A review. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 878, 58-73. doi:10.1016/j.nima.2017.07.063es_ES
dc.description.referencesPausch, G., Berthold, J., Enghardt, W., Römer, K., Straessner, A., Wagner, A., … Kögler, T. (2020). Detection systems for range monitoring in proton therapy: Needs and challenges. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 954, 161227. doi:10.1016/j.nima.2018.09.062es_ES
dc.description.referencesHueso-Gonzalez, F., & Bortfeld, T. (2020). Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: A Theoretical Study. IEEE Transactions on Radiation and Plasma Medical Sciences, 4(2), 170-183. doi:10.1109/trpms.2019.2930362es_ES
dc.description.referencesHaberer, T., Debus, J., Eickhoff, H., Jäkel, O., Schulz-Ertner, D., & Weber, U. (2004). The heidelberg ion therapy center. Radiotherapy and Oncology, 73, S186-S190. doi:10.1016/s0167-8140(04)80046-xes_ES
dc.description.referencesHara, K., Hata, K., Kim, S., Mishina, M., Sano, M., Seiya, Y., … Yasuoka, K. (1998). Radiation hardness and mechanical durability of Kuraray optical fibers. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 411(1), 31-40. doi:10.1016/s0168-9002(98)00281-2es_ES
dc.description.referencesJoram, C., Haefeli, G., & Leverington, B. (2015). Scintillating Fibre Tracking at High Luminosity Colliders. Journal of Instrumentation, 10(08), C08005-C08005. doi:10.1088/1748-0221/10/08/c08005es_ES
dc.description.referencesEkelhofRJ Studies for the LHCb SciFi Tracker - Development of Modules from Scintillating Fibres and Tests of their Radiation Hardness2016es_ES
dc.description.referencesOnline control of particle therapy - CLaRyS collaboration1825 DauvergneD Final MediNet Network Meeting2019es_ES
dc.description.referencesTessonnier, T., Mairani, A., Chen, W., Sala, P., Cerutti, F., Ferrari, A., … Parodi, K. (2018). Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison. Radiation Oncology, 13(1). doi:10.1186/s13014-017-0944-3es_ES
dc.description.referencesMein, S., Dokic, I., Klein, C., Tessonnier, T., Böhlen, T. T., Magro, G., … Mairani, A. (2019). Biophysical modeling and experimental validation of relative biological effectiveness (RBE) for 4He ion beam therapy. Radiation Oncology, 14(1). doi:10.1186/s13014-019-1295-zes_ES
dc.description.referencesSchoemers, C., Feldmeier, E., Naumann, J., Panse, R., Peters, A., & Haberer, T. (2015). The intensity feedback system at Heidelberg Ion-Beam Therapy Centre. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 795, 92-99. doi:10.1016/j.nima.2015.05.054es_ES
dc.description.referencesWerner, F., Bauer, C., Bernhard, S., Capasso, M., Diebold, S., Eisenkolb, F., … Zietara, K. (2017). Performance verification of the FlashCam prototype camera for the Cherenkov Telescope Array. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 876, 31-34. doi:10.1016/j.nima.2016.12.056es_ES
dc.description.referencesActis, M., Agnetta, G., Aharonian, F., Akhperjanian, A., Aleksić, J., … Antico, F. (2011). Design concepts for the Cherenkov Telescope Array CTA: an advanced facility for ground-based high-energy gamma-ray astronomy. Experimental Astronomy, 32(3), 193-316. doi:10.1007/s10686-011-9247-0es_ES
dc.description.referencesDal Bello, R., Magalhaes Martins, P., Graça, J., Hermann, G., Kihm, T., & Seco, J. (2019). Results from the experimental evaluation of CeBr scintillators for He prompt gamma spectroscopy. Medical Physics, 46(8), 3615-3626. doi:10.1002/mp.13594es_ES
dc.description.referencesPuehlhofer, G., Bauer, C., Bernhard, S., Capasso, M., Diebold, S., Eisenkolb, F., … Zietara, K. (2016). FlashCam: a fully-digital camera for the medium-sized telescopes of the Cherenkov Telescope Array. Proceedings of The 34th International Cosmic Ray Conference — PoS(ICRC2015). doi:10.22323/1.236.1039es_ES
dc.description.referencesTesta, M., Bajard, M., Chevallier, M., Dauvergne, D., Freud, N., Henriquet, P., … Testa, E. (2010). Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection. Radiation and Environmental Biophysics, 49(3), 337-343. doi:10.1007/s00411-010-0276-2es_ES
dc.description.referencesDal Bello, R., Magalhaes Martins, P., Brons, S., Hermann, G., Kihm, T., Seimetz, M., & Seco, J. (2020). Prompt gamma spectroscopy for absolute range verification of 12C ions at synchrotron-based facilities. Physics in Medicine & Biology, 65(9), 095010. doi:10.1088/1361-6560/ab7973es_ES
dc.description.references21768 LeoWR Techniques for Nuclear and Particle Physics Experiments: A How-to Approach1994es_ES
dc.description.referencesGraeff, C., Weber, U., Schuy, C., Saito, N., Volz, L., Piersimoni, P., … Kraemer, M. (2018). [OA027] Helium as a range probe in carbon ion therapy. Physica Medica, 52, 11. doi:10.1016/j.ejmp.2018.06.099es_ES
dc.description.referencesMazzucconi, D., Agosteo, S., Ferrarini, M., Fontana, L., Lante, V., Pullia, M., & Savazzi, S. (2018). Mixed particle beam for simultaneous treatment and online range verification in carbon ion therapy: Proof‐of‐concept study. Medical Physics, 45(11), 5234-5243. doi:10.1002/mp.13219es_ES
dc.description.referencesScintillating Fiber Trackers: recent developments and applications204 BlancF 14th ICATPP Conference on Astroparticle, Particle, Space Physics and Detectors for Physics Applications2013es_ES
dc.description.referencesJoramC UwerU LeveringtonBD KirnT BachmannS EkelhofRJ LHCb Scintillating Fibre Tracker Engineering Design Review Report: Fibres, Mats and Modules2015es_ES
dc.description.sponsorshipPM was supported by a research fellowship for postdoctoral researchers from the Alexander von Humboldt Foundation, Bonn, Germany. RD was supported by the International Max Planck Research School for Quantum Dynamics in Physics, Chemistry and Biology, Heidelberg, Germany.es_ES
dc.description.upvformatpfin13es_ES
dc.description.upvformatpinicio1es_ES
dc.description.volume8es_ES
dc.identifier.doi10.3389/fphy.2020.00169es_ES
dc.identifier.eissn2296-424Xes_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/161214
dc.languageIngléses_ES
dc.publisherFrontiers Mediaes_ES
dc.relation.ispartofFrontiers in Physicses_ES
dc.relation.pasarelaS\412954es_ES
dc.relation.publisherversionhttps://doi.org/10.3389/fphy.2020.00169es_ES
dc.relation.references10.1016/j.nima.2005.02.002es_ES
dc.relation.references10.1109/TNS.2005.852637es_ES
dc.relation.references10.1063/1.2975841es_ES
dc.relation.references10.1088/0031-9155/57/20/6429es_ES
dc.relation.references10.1088/0031-9155/57/11/3371es_ES
dc.relation.references10.1088/0031-9155/58/20/l37es_ES
dc.relation.references10.1088/0031-9155/59/18/5399es_ES
dc.relation.references10.1088/0031-9155/60/15/6063es_ES
dc.relation.references10.1088/0031-9155/61/6/2432es_ES
dc.relation.references10.1088/0031-9155/59/23/7089es_ES
dc.relation.references10.1088/0031-9155/60/16/6247es_ES
dc.relation.references10.1515/cdbme-2017-0023es_ES
dc.relation.references10.1088/1748-0221/12/05/p05025es_ES
dc.relation.references10.1016/j.nima.2004.07.002es_ES
dc.relation.references10.1088/1748-0221/7/10/p10024es_ES
dc.relation.references10.1088/1748-0221/8/01/p01004es_ES
dc.relation.references10.1016/j.nima.2013.06.033es_ES
dc.relation.references10.1016/j.nima.2017.01.021es_ES
dc.relation.references10.1088/1361-6633/aa94d3es_ES
dc.relation.references10.1088/0031-9155/37/10/006es_ES
dc.relation.references10.1088/0031-9155/37/10/007es_ES
dc.relation.references10.1088/0031-9155/61/20/r305es_ES
dc.relation.references10.1201/b19491es_ES
dc.relation.references10.1088/1361-6560/ab7a6ces_ES
dc.relation.references10.1016/j.nima.2016.06.057es_ES
dc.relation.references10.1088/1748-0221/13/05/p05030es_ES
dc.relation.references10.1088/1748-0221/12/12/c12056es_ES
dc.relation.references10.1016/j.nima.2017.07.063es_ES
dc.relation.references10.1016/j.nima.2018.09.062es_ES
dc.relation.references10.1109/TRPMS.2019.2930362es_ES
dc.relation.references10.1016/S0167-8140(04)80046-Xes_ES
dc.relation.references10.1016/S0168-9002(98)00281-2es_ES
dc.relation.references10.1088/1748-0221/10/08/c08005es_ES
dc.relation.references10.1186/s13014-017-0944-3es_ES
dc.relation.references10.1186/s13014-019-1295-zes_ES
dc.relation.references10.1016/j.nima.2015.05.054es_ES
dc.relation.references10.1016/j.nima.2016.12.056es_ES
dc.relation.references10.1007/s10686-011-9247-0es_ES
dc.relation.references10.1002/mp.13594es_ES
dc.relation.references10.22323/1.236.1039es_ES
dc.relation.references10.1007/s00411-010-0276-2es_ES
dc.relation.references10.1088/1361-6560/ab7973es_ES
dc.relation.references10.1016/j.ejmp.2018.06.099es_ES
dc.relation.references10.1002/mp.13219es_ES
dc.relation.references10.22323/1.213.0113es_ES
dc.rightsReconocimiento (by)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectPrompt-gammaes_ES
dc.subjectParticle tracking scintillating fiberses_ES
dc.subjectIon-beam therapyes_ES
dc.subjectSynchrotonses_ES
dc.titleA Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma Imaginges_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
person.identifier502729
relation.isAuthorOfPublication2f323ed7-a75f-4c7d-822b-e5f0860c6985
relation.isAuthorOfPublication.latestForDiscovery2f323ed7-a75f-4c7d-822b-e5f0860c6985
relation.isOrgUnitOfPublication2a147664-9b3c-4f73-8ea8-aefbad2ed456
relation.isOrgUnitOfPublication.latestForDiscovery2a147664-9b3c-4f73-8ea8-aefbad2ed456
upv.uuidae411fce-ad58-4bf8-88c7-c97428f46d3aes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Martins;Dal;Seimetz - A Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma I....pdf
Tamaño:
1.86 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial