Experimental evaluation of HCFO-1233zd-e as HFC-245fa replacement in an organic rankine cycle system for low temperature heat sources

dc.contributor.authorMolés-Ribera, Franciscoes_ES
dc.contributor.authorNavarro Esbrí, Joaquínes_ES
dc.contributor.authorPeris-Pérez, Bernardoes_ES
dc.contributor.authorMota-Babiloni, Adriánes_ES
dc.date.accessioned2017-05-23T12:33:22Z
dc.date.available2017-05-23T12:33:22Z
dc.date.issued2016-04-05
dc.description.abstract[EN] In this work an experimental evaluation of the working fluid HCFO-1233zd-E as HFC-245fa replacement in ORC systems for low temperature heat sources has been conducted. A fully monitored ORC module has been used to test both working fluids at different operating conditions. Due to the different densities of the working fluids, the mass flow rate for HCFO-1233zd-E is approximately 20% lower than for HFC-245fa. This causes thermal and electrical powers to be lower for HCF0-1233zd-E than for HFC245fa. However, net electrical efficiency is similar for both working fluids, ranging from 5% to 9.7% in the tested operating conditions. Regarding the expander performance, various performance indicators are addressed. The expander isentropic performance has a maximum value of 75%, with higher values for HCFO-1233zd-E than for HFC-245fa. The overall efficiency of the expander, similar for both working fluids, ranges from 44% to 57% in the experimental test range. (C) 2016 Elsevier Ltd. All rights reserved.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationMolés-Ribera, F.; Navarro Esbri, J.; Peris-Pérez, B.; Mota-Babiloni, A. (2016). Experimental evaluation of HCFO-1233zd-e as HFC-245fa replacement in an organic rankine cycle system for low temperature heat sources. Applied Thermal Engineering. 98:954-961. doi:10.1016/j.applthermaleng.2016.01.011es_ES
dc.description.sponsorshipThe authors thankfully acknowledge the cooperation of Rank (R) for its support in this project.en_EN
dc.description.upvformatpfin961es_ES
dc.description.upvformatpinicio954es_ES
dc.description.volume98es_ES
dc.identifier.doi10.1016/j.applthermaleng.2016.01.011
dc.identifier.issn1359-4311
dc.identifier.urihttps://riunet.upv.es/handle/10251/81657
dc.languageIngléses_ES
dc.publisherElsevieres_ES
dc.relation.ispartofApplied Thermal Engineeringes_ES
dc.relation.publisherversionhttp://doi.org/10.1016/j.applthermaleng.2016.01.011es_ES
dc.relation.senia299094es_ES
dc.rightsReconocimiento - No comercial - Sin obra derivada (by-nc-nd)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectLow GWP fluidses_ES
dc.subjectHFC-245faes_ES
dc.subjectOrganic Rankine Cyclees_ES
dc.subjectLow temperature heat sourceses_ES
dc.subjectExperimental evaluationes_ES
dc.subject.classificationINGENIERIA NUCLEARes_ES
dc.titleExperimental evaluation of HCFO-1233zd-e as HFC-245fa replacement in an organic rankine cycle system for low temperature heat sourceses_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuidbc2b275b-4d68-4eeb-a148-e66dddb528cfes_ES

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Experimental evaluation of HCFO-1233zd as HFC-245fa replacement....pdf
Tamaño:
2.04 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión del Autor.
Cargando...
Miniatura
Nombre:
Moles F - Experimental evaluation of HCFO-1233zd-E as HFC-245fa.pdf
Tamaño:
3.86 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial