Influence of rescanning mesh holes on the accuracy of an intraoral scanner: An in vivo study

dc.contributor.authorRevilla-León, Martaes_ES
dc.contributor.authorQuesada-Olmo, María Nieveses_ES
dc.contributor.authorGómez-Polo, Migueles_ES
dc.contributor.authorSicilia, Elenaes_ES
dc.contributor.authorFarjas-Abadia, Mercedeses_ES
dc.contributor.authorKois, John Ces_ES
dc.date.accessioned2022-09-05T18:02:55Z
dc.date.available2022-09-05T18:02:55Z
dc.date.issued2021-12es_ES
dc.description.abstract[EN] Objectives: To evaluate whether the cutting-off and rescanning procedures have an impact on the accuracy (trueness and precision) of the intraoral digital scan. Methods: A right quadrant digital scan (reference scan) of a participant was obtained using an intraoral scanner (IOS) (TRIOS 4; 3Shape A/S, Copenhagen, Denmark). The reference scan was duplicated 135 times and divided into 3 groups based on the number of rescanned mesh areas: 1 (G1 group), 2 (G2 group), and 3 (G3 group) mesh holes. Each group was subdivided into 3 subgroups depending on the mesh hole diameter: 2 mm- (G1-2, G2-2, and G3-2), 4 mm- (G1-4, G2-4, and G3-4), and 6 mm- (G1-6, G2-6, and G3-6) (n = 15). A software program (Geomagic; 3D Systems, Rock Hill, SC, USA) was used to assess the discrepancy between the reference and the experimental scans using the root mean square (RMS). Kruskal-Wallis and post hoc multiple comparison Dunn's tests were used to analyze the data (alpha=0.05). Results: Trueness ranged from 5 to 20 mu m and precision ranged from 2 to 10 mu m. For trueness assessment, KruskalWallis test revealed significant differences on the RMS error values among the groups tested (P<.05). The G3-6 group obtained the lowest trueness and lowest precision values, while the G1-2, G1-4, G2-2, G2-4, and G3-2 groups computed the highest trueness and precision values. When comparing groups with the same number of rescanned mesh holes but with different diameter, the higher the diameter of the rescanned mesh hole, the lower the trueness values computed; however, when comparing groups with the same diameter of the rescanned mesh hole but with differing number of rescanned mesh holes, no significant differences were found in the RMS values among the groups. For the precision evaluation, Levene's test showed a lack of equality of the variances, and therefore of the standard deviations. The F-test with Bonferroni correction identified significant differences between the SDs between group G3-6 and all the other groups. When comparing instead the interquartile range (IQRs) due to the non-normality of the data, groups G1 and G2 also showed lower IQR values or higher precision than groups G3. Conclusions: Cutting-off and rescanning procedures decreased the accuracy of the IOS tested. The higher the number and diameter of the rescanned areas, the lower the accuracy. Clinical significance: Cutting-off and rescanning procedures should be minimized in order to increase the accuracy of the IOS evaluated. The intended clinical use of the intraoral digital scan is a critical factor that might determine the scanning workflow procedures.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationRevilla-León, M.; Quesada-Olmo, MN.; Gómez-Polo, M.; Sicilia, E.; Farjas-Abadia, M.; Kois, JC. (2021). Influence of rescanning mesh holes on the accuracy of an intraoral scanner: An in vivo study. Journal of Dentistry. 115:1-7. https://doi.org/10.1016/j.jdent.2021.103851es_ES
dc.description.upvformatpfin7es_ES
dc.description.upvformatpinicio1es_ES
dc.description.volume115es_ES
dc.identifier.doi10.1016/j.jdent.2021.103851es_ES
dc.identifier.issn0300-5712es_ES
dc.identifier.pmid34656658es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/185276
dc.languageIngléses_ES
dc.publisherElsevieres_ES
dc.relation.ispartofJournal of Dentistryes_ES
dc.relation.pasarelaS\453038es_ES
dc.relation.publisherversionhttps://doi.org/10.1016/j.jdent.2021.103851es_ES
dc.relation.references10.11607/ijp.6468es_ES
dc.relation.references10.1038/sj.ebd.6401224es_ES
dc.relation.references10.1016/j.prosdent.2015.12.017es_ES
dc.relation.references10.11607/jomi.3625es_ES
dc.relation.references10.1111/jopr.13162es_ES
dc.relation.references10.1186/s12903-019-0792-7es_ES
dc.relation.references10.1016/j.prosdent.2020.03.005es_ES
dc.relation.references10.11607/jomi.6855es_ES
dc.relation.references10.1016/j.prosdent.2016.09.024es_ES
dc.relation.references10.11607/ijp.6903es_ES
dc.relation.references10.11607/ijp.6940es_ES
dc.relation.references10.1016/j.prosdent.2017.05.002es_ES
dc.relation.references10.1016/j.prosdent.2015.12.018es_ES
dc.relation.references10.1111/jopr.13158es_ES
dc.relation.references10.3390/ma14020365es_ES
dc.relation.references10.4041/kjod.2016.46.1.3es_ES
dc.relation.references10.1016/j.prosdent.2019.06.003es_ES
dc.relation.references10.1111/jopr.13135es_ES
dc.relation.references10.1111/jopr.13276es_ES
dc.relation.references10.1186/s12903-020-01090-xes_ES
dc.relation.references10.1111/jerd.12485es_ES
dc.relation.references10.1186/s40510-020-00337-1es_ES
dc.relation.references10.1016/j.prosdent.2019.06.004es_ES
dc.relation.references10.1111/jopr.13205es_ES
dc.relation.references10.1016/j.jdent.2021.103690es_ES
dc.relation.references10.1016/j.prosdent.2019.11.018es_ES
dc.relation.references10.1111/cid.12472es_ES
dc.relation.references10.1186/s12903-017-0415-0es_ES
dc.relation.references10.1109/34.121791es_ES
dc.relation.references10.1371/journal.pone.0164694es_ES
dc.relation.references10.1016/j.jdent.2021.103680es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsCerradoes_ES
dc.subjectAccuracyes_ES
dc.subjectDigital scanes_ES
dc.subjectMesh holees_ES
dc.subjectIntraoral scanneres_ES
dc.subjectRescanning procedureses_ES
dc.subject.classificationINGENIERIA CARTOGRAFICA, GEODESIA Y FOTOGRAMETRIAes_ES
dc.titleInfluence of rescanning mesh holes on the accuracy of an intraoral scanner: An in vivo studyes_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuidc9906ae5-b4e1-4f12-8674-eddb59b5e2b5es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Revilla-LeonQuesada-OlmoGomez-Polo - Influence of rescanning mesh holes on the accuracy of an int....pdf
Tamaño:
6.88 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial