Composite modular floor prototype for emergency housing applications:Experimental and analytical approach

dc.contributor.authorAbdolpour, Hassanes_ES
dc.contributor.authorGarzón-Roca, Julioes_ES
dc.contributor.authorEscusa, Gonçaloes_ES
dc.contributor.authorSena-Cruz, J.M.es_ES
dc.contributor.authorBarros, J.es_ES
dc.contributor.authorValente, Isabeles_ES
dc.contributor.funderAgência Nacional de Inovação, Portugales_ES
dc.contributor.funderEuropean Regional Development Fund
dc.date.accessioned2020-06-10T03:31:34Z
dc.date.available2020-06-10T03:31:34Z
dc.date.issued2018-06-01es_ES
dc.description.abstract[EN] The present paper explores a new modular floor prototype to be used in emergency houses. The prototype is composed of a frame structure made of glass-fiber-reinforced polymer (GFRP) tubular pultruded profiles, a slab made of sandwich panels with a polyurethane (PU) foam core and GFRP skins, and a tailored connection system that provides integrity between assembled components. A series of experimental tests are carried out including flexural tests on a single panel, on two and three connected panels, and on the assembled floor prototype. The behaviour of the panels is analysed when they are not considered part of the GFRP framed structure, namely the failure mechanisms and the efficiency of the proposed connection system between the panels. The performance of the floor prototype to support typical load conditions of residential houses is also assessed. Additionally, an analytical model was used to deeper study the behavior of the developed sandwich panels, connection system and the modular floor prototype.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationAbdolpour, H.; Garzón-Roca, J.; Escusa, G.; Sena-Cruz, J.; Barros, J.; Valente, I. (2018). Composite modular floor prototype for emergency housing applications:Experimental and analytical approach. Journal of Composite Materials. 52(13):1747-1764. https://doi.org/10.1177/0021998317733318es_ES
dc.description.issue13es_ES
dc.description.referencesJohnson, C. (2007). Impacts of prefabricated temporary housing after disasters: 1999 earthquakes in Turkey. Habitat International, 31(1), 36-52. doi:10.1016/j.habitatint.2006.03.002es_ES
dc.description.referencesArslan, H., & Cosgun, N. (2008). Reuse and recycle potentials of the temporary houses after occupancy: Example of Duzce, Turkey. Building and Environment, 43(5), 702-709. doi:10.1016/j.buildenv.2007.01.051es_ES
dc.description.referencesDodoo, A., & Gustavsson, L. (2013). Life cycle primary energy use and carbon footprint of wood-frame conventional and passive houses with biomass-based energy supply. Applied Energy, 112, 834-842. doi:10.1016/j.apenergy.2013.04.008es_ES
dc.description.referencesDatin, P. L., & Prevatt, D. O. (2013). Using instrumented small-scale models to study structural load paths in wood-framed buildings. Engineering Structures, 54, 47-56. doi:10.1016/j.engstruct.2013.03.039es_ES
dc.description.referencesImperadori, M., Salvalai, G., & Pusceddu, C. (2014). Air Shelter House Technology and its Application to Shelter Units: the Case of Scaffold House and Cardboard Shelter Installations. Procedia Economics and Finance, 18, 552-559. doi:10.1016/s2212-5671(14)00975-7es_ES
dc.description.referencesLjunggren, F., & Ågren, A. (2011). Potential solutions to improved sound performance of volume based lightweight multi-storey timber buildings. Applied Acoustics, 72(4), 231-240. doi:10.1016/j.apacoust.2010.11.007es_ES
dc.description.referencesWinandy, J. E., Hunt, J. F., Turk, C., & Anderson, J. R. (2006). Emergency housing systems from three-dimensional engineered fiberboard : temporary building systems for lightweight, portable, easy-to-assemble, reusable, recyclable, and biodegradable structures. doi:10.2737/fpl-gtr-166es_ES
dc.description.referencesKootsookos, A., & Burchill, P. . (2004). The effect of the degree of cure on the corrosion resistance of vinyl ester/glass fibre composites. Composites Part A: Applied Science and Manufacturing, 35(4), 501-508. doi:10.1016/j.compositesa.2003.08.010es_ES
dc.description.referencesNguyen, C. H., Chandrashekhara, K., & Birman, V. (2012). Multifunctional thermal barrier coating in aerospace sandwich panels. Mechanics Research Communications, 39(1), 35-43. doi:10.1016/j.mechrescom.2011.10.003es_ES
dc.description.referencesAllard, J. F., & Atalla, N. (2009). Propagation of Sound in Porous Media. doi:10.1002/9780470747339es_ES
dc.description.referencesSousa, J. M., Correia, J. R., Cabral-Fonseca, S., & Diogo, A. C. (2014). Effects of thermal cycles on the mechanical response of pultruded GFRP profiles used in civil engineering applications. Composite Structures, 116, 720-731. doi:10.1016/j.compstruct.2014.06.008es_ES
dc.description.referencesCorreia, J. R., Cabral-Fonseca, S., Branco, F. A., Ferreira, J. G., Eusébio, M. I., & Rodrigues, M. P. (2006). Durability of pultruded glass-fiber-reinforced polyester profiles for structural applications. Mechanics of Composite Materials, 42(4), 325-338. doi:10.1007/s11029-006-0042-3es_ES
dc.description.referencesRizkalla, S., Lucier, G., & Dawood, M. (2012). Innovative Use of FRP for the Precast Concrete Industry. Advances in Structural Engineering, 15(4), 565-574. doi:10.1260/1369-4332.15.4.565es_ES
dc.description.referencesOppe, M. W., & Knippers, J. (2011). Application of bolted connections in fibre-reinforced polymers. Proceedings of the Institution of Civil Engineers - Structures and Buildings, 164(5), 321-332. doi:10.1680/stbu.2011.164.5.321es_ES
dc.description.referencesShawkat, W., Honickman, H., & Fam, A. (2008). Investigation of a Novel Composite Cladding Wall Panel in Flexure. Journal of Composite Materials, 42(3), 315-330. doi:10.1177/0021998307087965es_ES
dc.description.referencesSharaf, T., Shawkat, W., & Fam, A. (2010). Structural Performance of Sandwich Wall Panels with Different Foam Core Densities in One-way Bending. Journal of Composite Materials, 44(19), 2249-2263. doi:10.1177/0021998310369577es_ES
dc.description.referencesCorreia, J. R., Garrido, M., Gonilha, J. A., Branco, F. A., & Reis, L. G. (2012). GFRP sandwich panels with PU foam and PP honeycomb cores for civil engineering structural applications. International Journal of Structural Integrity, 3(2), 127-147. doi:10.1108/17579861211235165es_ES
dc.description.referencesKeller, T., Haas, C., & Vallée, T. (2008). Structural Concept, Design, and Experimental Verification of a Glass Fiber-Reinforced Polymer Sandwich Roof Structure. Journal of Composites for Construction, 12(4), 454-468. doi:10.1061/(asce)1090-0268(2008)12:4(454)es_ES
dc.description.referencesMousa, M. A., & Uddin, N. (2011). Global buckling of composite structural insulated wall panels. Materials & Design, 32(2), 766-772. doi:10.1016/j.matdes.2010.07.026es_ES
dc.description.referencesGarrido, M., Correia, J. R., Keller, T., & Branco, F. A. (2015). Adhesively bonded connections between composite sandwich floor panels for building rehabilitation. Composite Structures, 134, 255-268. doi:10.1016/j.compstruct.2015.08.080es_ES
dc.description.referencesZenkert, D., Shipsha, A., & Persson, K. (2004). Static indentation and unloading response of sandwich beams. Composites Part B: Engineering, 35(6-8), 511-522. doi:10.1016/j.compositesb.2003.09.006es_ES
dc.description.referencesPetras, A., & Sutcliffe, M. P. F. (1999). Indentation resistance of sandwich beams. Composite Structures, 46(4), 413-424. doi:10.1016/s0263-8223(99)00109-9es_ES
dc.description.referencesRizov, V., Shipsha, A., & Zenkert, D. (2005). Indentation study of foam core sandwich composite panels. Composite Structures, 69(1), 95-102. doi:10.1016/j.compstruct.2004.05.013es_ES
dc.description.referencesPetras, A., & Sutcliffe, M. P. . (2000). Indentation failure analysis of sandwich beams. Composite Structures, 50(3), 311-318. doi:10.1016/s0263-8223(00)00122-7es_ES
dc.description.referencesBorsellino, C., Calabrese, L., & Valenza, A. (2004). Experimental and numerical evaluation of sandwich composite structures. Composites Science and Technology, 64(10-11), 1709-1715. doi:10.1016/j.compscitech.2004.01.003es_ES
dc.description.referencesFam, A., & Sharaf, T. (2010). Flexural performance of sandwich panels comprising polyurethane core and GFRP skins and ribs of various configurations. Composite Structures, 92(12), 2927-2935. doi:10.1016/j.compstruct.2010.05.004es_ES
dc.description.referencesCarlsson, L. A., & Kardomateas, G. A. (2011). Structural and Failure Mechanics of Sandwich Composites. Solid Mechanics and Its Applications. doi:10.1007/978-1-4020-3225-7es_ES
dc.description.referencesEskandari, H. (2003). The effect of shear deformation on material selection for bending components. Materials & Design, 24(2), 143-149. doi:10.1016/s0261-3069(02)00125-5es_ES
dc.description.sponsorshipThe author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This work is part of the research project ClickHouse-Development of a prefabricated emergency house prototype made of composites materials, involving the company ALTO - Perfis Pultrudidos, Lda., CERis/Instituto Superior Tecnico and ISISE/University of Minho, supported by FEDER funds through the Operational Program for Competitiveness Factors - COMPETE and the Portuguese National Agency of Innovation (ADI) - project no. 38967.es_ES
dc.description.upvformatpfin1764es_ES
dc.description.upvformatpinicio1747es_ES
dc.description.volume52es_ES
dc.identifier.doi10.1177/0021998317733318es_ES
dc.identifier.issn0021-9983es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/145854
dc.languageIngléses_ES
dc.publisherSAGE Publicationses_ES
dc.relation.ispartofJournal of Composite Materialses_ES
dc.relation.pasarelaS\343654es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/ANI//COMPETE-38967/es_ES
dc.relation.publisherversionhttps://doi.org/10.1177/0021998317733318es_ES
dc.relation.references10.1016/j.habitatint.2006.03.002es_ES
dc.relation.references10.1016/j.buildenv.2007.01.051es_ES
dc.relation.references10.1016/j.apenergy.2013.04.008es_ES
dc.relation.references10.1016/j.engstruct.2013.03.039es_ES
dc.relation.references10.1016/S2212-5671(14)00975-7es_ES
dc.relation.references10.1016/j.apacoust.2010.11.007es_ES
dc.relation.references10.2737/FPL-GTR-166es_ES
dc.relation.references10.1016/j.compositesa.2003.08.010es_ES
dc.relation.references10.1016/j.mechrescom.2011.10.003es_ES
dc.relation.references10.1002/9780470747339es_ES
dc.relation.references10.1016/j.compstruct.2014.06.008es_ES
dc.relation.references10.1007/s11029-006-0042-3es_ES
dc.relation.references10.1260/1369-4332.15.4.565es_ES
dc.relation.references10.1680/stbu.2011.164.5.321es_ES
dc.relation.references10.1177/0021998307087965es_ES
dc.relation.references10.1177/0021998310369577es_ES
dc.relation.references10.1108/17579861211235165es_ES
dc.relation.references10.1061/(ASCE)1090-0268(2008)12:4(454)es_ES
dc.relation.references10.1016/j.matdes.2010.07.026es_ES
dc.relation.references10.1016/j.compstruct.2015.08.080es_ES
dc.relation.references10.1016/j.compositesb.2003.09.006es_ES
dc.relation.references10.1016/S0263-8223(99)00109-9es_ES
dc.relation.references10.1016/j.compstruct.2004.05.013es_ES
dc.relation.references10.1016/S0263-8223(00)00122-7es_ES
dc.relation.references10.1016/j.compscitech.2004.01.003es_ES
dc.relation.references10.1016/j.compstruct.2010.05.004es_ES
dc.relation.references10.1016/j.compstruct.2016.05.069es_ES
dc.relation.references10.1163/156855111X610208es_ES
dc.relation.references10.1007/978-1-4020-3225-7es_ES
dc.relation.references10.1016/j.engstruct.2012.03.028es_ES
dc.relation.references10.1016/S0261-3069(02)00125-5es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectEmergency housees_ES
dc.subjectComposite materialses_ES
dc.subjectGFRP pultruded profileses_ES
dc.subjectSandwich panelses_ES
dc.subjectGFRP skinses_ES
dc.subjectPU foam corees_ES
dc.subject.classificationINGENIERIA DEL TERRENOes_ES
dc.titleComposite modular floor prototype for emergency housing applications:Experimental and analytical approaches_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuide2fc1ec2-14b7-4711-a174-bed206c4e5fees_ES

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Abdolpour;Garzón-Roca;Escusa - Composite modular floor prototype for emergency housing applicatio....pdf
Tamaño:
1.55 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión del Autor.
Cargando...
Miniatura
Nombre:
Composite modular floor prototype for emergency housing applications experimentan and analytical approach_Editor Version.pdf
Tamaño:
1.93 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial