TECHNICAL NOTE: NON INVASIVE METHOD TO PROTECT THE EXTERNAL PART OF CATHETERS OR FLOW PROBES CHRONICALLY IMPLANTED IN RABBITS

dc.contributor.authorFortun-Lamothe, L.
dc.contributor.authorLamboley-Gaüzere, B.
dc.date.accessioned2011-03-15T11:15:13Z
dc.date.available2011-03-15T11:15:13Z
dc.date.issued1998
dc.date.updated2011-03-14T12:31:25Z
dc.description.abstract[EN] This technical note describe the steps of fabrication of a protective backpack for the extemal part of catheters or flow probes chronically implantad in rabbits. This backpack is made with fabric and velera®, and the straps are made with electric wire which cannot be nibbled by the animal. This method is non invasiva and does not modify the animal behaviour (caecotrophy, suckling, washing .... ).en_EN
dc.description.abstract[FR] Note technique : Méthode non invasive de protection de l'extrémité externe des catheters et des sondes débitrnétriques implantés en chronique chez le lapin. Cette note technique décrit les étapes de fabrication d'un sac a dos pour lapin permettant de protéger de fayon efficace l'extrémité de cathéters ou de sondes débitmétriques implantés en chronique. Ce sac ti dos est fabriqué ti l'aide de tissu et de velero®, les bretelles sont en fil électrique et ne peuvent pas étre grignotées par l'animal. Cette méthode présente l'avantage d'étre non invasiva et ne modifie pas le comportement de l'animal (caecotrophie, allaitement, toilette .. ).
dc.description.accrualMethodSWORDes_ES
dc.description.bibliographicCitationFortun-Lamothe, L.; Lamboley-Gaüzere, B. (1998). TECHNICAL NOTE: NON INVASIVE METHOD TO PROTECT THE EXTERNAL PART OF CATHETERS OR FLOW PROBES CHRONICALLY IMPLANTED IN RABBITS. World Rabbit Science. 06(2). https://doi.org/10.4995/wrs.1998.354es_ES
dc.description.issue2
dc.description.volume06
dc.identifier.doi10.4995/wrs.1998.354
dc.identifier.eissn1989-8886es_ES
dc.identifier.issn1257-5011
dc.identifier.urihttps://riunet.upv.es/handle/10251/10367
dc.languageIngléses_ES
dc.publisherWorld Rabbit Science. ICTA. UPVes_ES
dc.relation.ispartofWorld Rabbit Science
dc.relation.publisherversionhttps://doi.org/10.4995/wrs.1998.354
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsAbiertoes_ES
dc.titleTECHNICAL NOTE: NON INVASIVE METHOD TO PROTECT THE EXTERNAL PART OF CATHETERS OR FLOW PROBES CHRONICALLY IMPLANTED IN RABBITSes_ES
dc.typeArtículoes_ES
dspace.entity.typePublication
upv.uuideb560db6-76a4-4041-8463-e3ad862f0f6des_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
354-637-1-SM.pdf
Tamaño:
233.25 KB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
361 B
Formato:
Item-specific license agreed upon to submission
Descripción: