A novel sensor for monitoring of iron (III) ions based on porphyrins

dc.contributor.authorVlascici, Danaes_ES
dc.contributor.authorFagadar-Cosma, Eugeniaes_ES
dc.contributor.authorPopa, Iulianaes_ES
dc.contributor.authorChiriac, Vlades_ES
dc.contributor.authorGil Agustí, María Teresaes_ES
dc.contributor.funderEuropean Commission
dc.contributor.funderEuropean Social Fundes_ES
dc.contributor.funderExecutive Agency for Higher Education, Scientific Research, Development and Innovation Funding, Rumaníaes_ES
dc.date.accessioned2013-05-14T09:13:07Z
dc.date.available2013-05-14T09:13:07Z
dc.date.issued2012
dc.description.abstract[EN] Three A3B porphyrins with mixed carboxy-, phenoxy-, pyridyl- and dimethoxysubstituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10−7 –1 × 10−1 M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationVlascici, D.; Fagadar-Cosma, E.; Popa, I.; Chiriac, V.; Gil Agustí, MT. (2012). A novel sensor for monitoring of iron (III) ions based on porphyrins. Sensors. 12(6):8193-8203. https://doi.org/10.3390/s120608193es_ES
dc.description.issue6es_ES
dc.description.sponsorshipThe research leading to these results has received funding from the European Community’s Seventh Framework Programme (FP7/2007-2013) under grant agreement n° 266090 (SOMABAT), Romanian PNCDI2 Program-Module III-EU 128/2011 and is a result of collaboration between the coauthors within the project POSDRU/21/1.5/G/38347.
dc.description.upvformatpfin8203es_ES
dc.description.upvformatpinicio8193es_ES
dc.description.volume12es_ES
dc.identifier.doi10.3390/s120608193
dc.identifier.issn1424-8220
dc.identifier.pmcidPMC3436024en_EN
dc.identifier.pmid22969395en_EN
dc.identifier.urihttps://riunet.upv.es/handle/10251/28815
dc.languageIngléses_ES
dc.publisherMDPIes_ES
dc.relation.ispartofSensorses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/266090/EU/Development of novel SOlid MAterials for high power Li polymer BATteries (SOMABAT). Recyclability of components/SOMABAT/en_EN
dc.relation.projectIDinfo:eu-repo/grantAgreement/UEFISCDI/PNCDI II/128%2F2011/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/ESF//POSDRU%2F21%2F1.5%2FG%2F38347/es_ES
dc.relation.publisherversionhttp://dx.doi.org/10.3390/s120608193es_ES
dc.relation.senia232118
dc.rightsReconocimiento (by)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectporphyrinses_ES
dc.subjection-selective electrodees_ES
dc.subjectpotentiometryes_ES
dc.subjectLithium ion batterieses_ES
dc.subjectIron(III)es_ES
dc.subjectPVC membranees_ES
dc.titleA novel sensor for monitoring of iron (III) ions based on porphyrinses_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuidececd6c3-61b4-4d0e-a96f-ae9ab91345ffes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
sensors-12-08193.pdf
Tamaño:
192.98 KB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial en abierto