An architecture and protocol for smart continuous eHealth monitoring using 5G

dc.contributor.affiliationDepartamento de Comunicaciones
dc.contributor.affiliationEscuela Politécnica Superior de Gandia
dc.contributor.affiliationInstituto de Investigación para la Gestión Integrada de Zonas Costeras
dc.contributor.authorLloret, Jaime
dc.contributor.authorParra-Boronat, Lorenaes_ES
dc.contributor.authorAbdullah, Miran Taha Abdullahes_ES
dc.contributor.authorTomás Gironés, Jesús
dc.contributor.funderMinisterio de Educación, Cultura y Deporte
dc.date.accessioned2018-04-22T04:11:54Z
dc.date.available2018-04-22T04:11:54Z
dc.date.issued2017es_ES
dc.description.abstract[EN] Continuous monitoring of chronic patients improves their quality of life and reduces the economic costs of the sanitary system. However, in order to ensure a good monitoring, high bandwidth and low delay are needed. The 5G technology offers higher bandwidth, lower delays and packets loss than previous technologies. This paper presents an architecture for smart eHealth monitoring of chronic patients. The architecture elements include wearable devices, to collect measures from the body, and a smartphone at the patient side in order to process the data received from the wearable devices. We also need a DataBase with an intelligent system able to send an alarm when it detects that it is happening something anomalous. The intelligent system uses machine learning in BigData taken from different hospitals and the data received from the patient to diagnose and generate alarms. Experiment tests have been done to simulate the traffic from many users to the DataBase in order to evaluate the suitability of 5G in our architecture. When there are few users (less than 200 users), we do not find big differences of round trip time between 4G and 5G, but when there are more users, like 1000 users, it increases considerably reaching 4 times more in 4G The Packet Loss is almost null in 4G until 300 users, while in 5G it is possible to keep it null until 700 users. Our results point out that in order to have high number of patients continuously monitored, it is necessary to use the 5G network because it offers low delays and guarantees the availability of bandwidth for all users.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationLloret, J.; Parra-Boronat, L.; Abdullah, MTA.; Tomás Gironés, J. (2017). An architecture and protocol for smart continuous eHealth monitoring using 5G. Computer Networks. 129(2):340-351. https://doi.org/10.1016/j.comnet.2017.05.018es_ES
dc.description.issue2es_ES
dc.description.sponsorshipThis work has been partially supported by the "Ministerio de Educacion, Cultura y Deporte", through the "Ayudas para contratos predoctorales de Formacion del Profesorado Universitario FPU (Convocatoria 2014)". Grant number FPU14/02953.es_ES
dc.description.upvformatpfin351es_ES
dc.description.upvformatpinicio340es_ES
dc.description.volume129es_ES
dc.identifier.doi10.1016/j.comnet.2017.05.018es_ES
dc.identifier.issn1389-1286es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/100822
dc.languageIngléses_ES
dc.publisherElsevieres_ES
dc.relation.ispartofComputer Networkses_ES
dc.relation.pasarelaS\352644es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/MECD//FPU14%2F02953/ES/FPU14%2F02953/
dc.relation.publisherversionhttps://doi.org/10.1016/j.comnet.2017.05.018es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjecteHealth architecturees_ES
dc.subjectContinuous monitoringes_ES
dc.subjectMachine learninges_ES
dc.subject5Ges_ES
dc.subjectWearable sensorses_ES
dc.subjectSmart protocoles_ES
dc.subject.classificationTECNOLOGIA DEL MEDIO AMBIENTEes_ES
dc.subject.classificationINGENIERIA TELEMATICAes_ES
dc.titleAn architecture and protocol for smart continuous eHealth monitoring using 5Ges_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
person.identifier260345
person.identifier1296
person.identifier.orcid0000-0002-0862-0533
person.identifier.orcid0000-0002-0358-0325
relation.isAuthorOfPublicatione6f912f7-e605-4217-ac55-555ebb925e03
relation.isAuthorOfPublication793bbc53-7355-43f7-a75c-8573098641f2
relation.isAuthorOfPublication.latestForDiscoverye6f912f7-e605-4217-ac55-555ebb925e03
relation.isOrgUnitOfPublication02a0f2c5-c452-4e1d-a7d9-b731347d078c
relation.isOrgUnitOfPublication1db03441-9881-4e7e-a0a9-daca18341155
relation.isOrgUnitOfPublication87703ab1-3cc0-4e89-a2a3-58a7c746bee1
relation.isOrgUnitOfPublication.latestForDiscovery02a0f2c5-c452-4e1d-a7d9-b731347d078c
upv.uuided2ff712-5d5d-45c6-bca6-c0f4777d15afes_ES

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Architecture for continuous intelligent eHealth monitoring using 5G_v6.pdf
Tamaño:
1.34 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión del Autor.
Cargando...
Miniatura
Nombre:
1-s2.0-S1389128617302189-main.pdf
Tamaño:
2.58 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial