Analysis of the variation mechanism in the main energetic parameters in a single-stage vapour compression plant

dc.contributor.authorCabello, R.es_ES
dc.contributor.authorNavarro-Esbri, J.es_ES
dc.contributor.authorLlopis, R.es_ES
dc.contributor.authorTorrella Alcaraz, Enriquees_ES
dc.contributor.funderGeneralitat Valencianaes_ES
dc.date.accessioned2020-04-01T07:15:52Z
dc.date.available2020-04-01T07:15:52Z
dc.date.issued2007es_ES
dc.description.abstract[EN] Based on a previously developed and validated steady-state model of a single-stage vapour compression plant, the present paper describes an in-depth study directed to examine the consequences of changes in the operating conditions in such a plant. These include modifications of condensing and evaporating temperatures and the total superheating degree at compressor suction, which are the main energy parameters in a refrigeration plant. The aim of this work is not to determine the final energy state when the operating conditions are modified, which could be achieved using the steady-state model, but to study the mechanism that explains the variation. The pursuit of this goal implies conducting a detailed analysis of the performance and influence of several intermediate variables, the evolution of which has a direct effect on the final cooling capacity, compression power and COP values. The results obtained show the significant influence of the suction pressure (through the specific suction volume) on the compression power and cooling capacity, while the condensing and evaporating temperatures have a similar influence on the COP.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationCabello, R.; Navarro-Esbri, J.; Llopis, R.; Torrella Alcaraz, E. (2007). Analysis of the variation mechanism in the main energetic parameters in a single-stage vapour compression plant. Applied Thermal Engineering. 27(1):167-176. https://doi.org/10.1016/j.applthermaleng.2006.05.009es_ES
dc.description.issue1es_ES
dc.description.sponsorshipThe authors are indebted to the Generalitat Valenciana for partial support under project GV05/091es_ES
dc.description.upvformatpfin176es_ES
dc.description.upvformatpinicio167es_ES
dc.description.volume27es_ES
dc.identifier.doi10.1016/j.applthermaleng.2006.05.009es_ES
dc.identifier.issn1359-4311es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/139935
dc.languageIngléses_ES
dc.publisherElsevieres_ES
dc.relation.ispartofApplied Thermal Engineeringes_ES
dc.relation.pasarelaS\33129es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/GVA//GV05%2F091/es_ES
dc.relation.publisherversionhttps://doi.org/10.1016/j.applthermaleng.2006.05.009es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsCerradoes_ES
dc.subjectVapour compression cyclees_ES
dc.subjectVariations in operating parameterses_ES
dc.subjectEnergy efficiencyes_ES
dc.subjectSpecific suction volumenes_ES
dc.subject.classificationMAQUINAS Y MOTORES TERMICOSes_ES
dc.titleAnalysis of the variation mechanism in the main energetic parameters in a single-stage vapour compression plantes_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuidf6f628ef-a669-44fe-9cde-2de066874df2es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Cabello;Navarro-Esbri;Llopis - Analysis of the variation mechanism in the main energetic paramete....pdf
Tamaño:
453.38 KB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial