- -

Video approach to chemiluminescence detection using a low-cost complementary metal oxide semiconductor (CMOS)-based camera: determination of paracetamol in pharmaceutical formulations

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Video approach to chemiluminescence detection using a low-cost complementary metal oxide semiconductor (CMOS)-based camera: determination of paracetamol in pharmaceutical formulations

Mostrar el registro completo del ítem

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/100326

Ficheros en el ítem

Metadatos del ítem

Título: Video approach to chemiluminescence detection using a low-cost complementary metal oxide semiconductor (CMOS)-based camera: determination of paracetamol in pharmaceutical formulations
Autor: Lahuerta-Zamora, Luis Mellado Romero, Ana María
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil
Fecha difusión:
Resumen:
[EN] A new system for continuous flow chemiluminescence detection, based on the use of a simple and low-priced lens-free digital camera (with complementary metal oxide semiconductor technology) as a detector, is proposed ...[+]
Palabras clave: Flow chemiluminescence , CMOS camera , ImageJ , Pharmaceutical analysis
Derechos de uso: Reserva de todos los derechos
Fuente:
Analytical and Bioanalytical Chemistry. (issn: 1618-2642 )
DOI: 10.1007/s00216-017-0334-6
Editorial:
Springer-Verlag
Versión del editor: https://doi.org/10.1007/s00216-017-0334-6
Tipo: Artículo

References

Worsfold PJ, Robards K. Analytical applications of liquid phase chemiluminescence. Anal Chim Acta. 1992;266:147–73. doi: 10.1016/0003-2670(92)85040-D .

Fuster Mestre Y, Lahuerta-Zamora L, Martínez Calatayud J. Flow-chemiluminescence: a growing modality of pharmaceutical analysis. Luminescence. 2001;16(3):213–35. doi: 10.1002/bio.608 .

Roda A, Pasini P, Mirasoli M, Michelini E, Guardigli M. Biotechnological applications of bioluminescence and chemiluminescence. Trends Biotechnol. 2004;22(6):295–303. doi: 10.1016/j.tibtech.2004.03.011 . [+]
Worsfold PJ, Robards K. Analytical applications of liquid phase chemiluminescence. Anal Chim Acta. 1992;266:147–73. doi: 10.1016/0003-2670(92)85040-D .

Fuster Mestre Y, Lahuerta-Zamora L, Martínez Calatayud J. Flow-chemiluminescence: a growing modality of pharmaceutical analysis. Luminescence. 2001;16(3):213–35. doi: 10.1002/bio.608 .

Roda A, Pasini P, Mirasoli M, Michelini E, Guardigli M. Biotechnological applications of bioluminescence and chemiluminescence. Trends Biotechnol. 2004;22(6):295–303. doi: 10.1016/j.tibtech.2004.03.011 .

Yinhuan L, Weifen N, Jiuru L. Talanta. 2007;71:1124–9.

Gámiz-Gracia L, García-Campaña AM, Huertas-Pérez JF, Lara FJ. Chemiluminescence detection in liquid chromatography: applications to clinical, pharmaceutical, environmental and food analysis—a review. Anal Chim Acta. 2009;640(1–2):7–28. doi: 10.1016/j.aca.2009.03.017 .

Roda A, Guardigli M. Analytical chemiluminescence and bioluminescence: latest achievements and new horizons. Anal Bioanal Chem. 2012;402:69–76. doi: 10.1007/s00216-011-5455-8 .

Iranifam M. Revisiting flow-chemiluminescence techniques: pharmaceutical analysis. Luminescence. 2012;28(6):798–820. doi: 10.1002/bio.2441 .

Byrne L, Barker J, Pennarun-Thomas G, Diamond D. Digital imaging as a detector for generic analytical measurements. TrAC–Trend Anal Chem. 2000;19:517–22. doi: 10.1016/S0165-9936(00)00019-4 .

Rodrigues ERGO, Lapa RAS. CMOS arrays as chemiluminescence detectors on microfluidic devices. Anal Bioanal Chem. 2010;397:381–8. doi: 10.1007/s00216-010-3518-x .

Capitán-Vallvey LF, López-Ruiz N, Martínez-Olmos A, Erenas MM, Palma AJ. Recent developments in computer vision-based analytical chemistry: a tutorial review. Anal Chim Acta. 2015;899:23–56. doi: 10.1016/j.aca.2015.10.009 .

Lahuerta-Zamora L, Alemán López PA, Antón Fos GM, Martín Algarra R, Mellado-Romero AM, Martínez Calatayud J. Quantitative colorimetric-imaging analysis of nickel in iron meteorites. Talanta. 2011;83(5):1575–9. doi: 10.1016/j.talanta.2010.11.058 .

Lahuerta-Zamora L, Pérez Gracia T. Using digital photography to implement the McFarland method. J R Soc Interface. 2012;9:1892–7. doi: 10.1098/rsif.2011.0809 .

Wongwilai W, Lapanantnoppakhun S, Grudpan S, Grudpan K. Webcam camera as a detector for a simple lab-on-chip time based approach. Talanta. 2010;81:1137–41. doi: 10.1016/j.talanta.2010.01.058 .

Balsam J, Bruck HA, Kostov Y, Rasooly A. Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam. Sens Actuators B Chem. 2012;171–172:141–7. doi: 10.1016/j.snb.2012.02.003 .

Marquette CA, Blum LJ. Applications of the luminol chemiluminescent reaction in analytical chemistry. Anal Bioanal Chem. 2006;385:546–54. doi: 10.1007/s00216-006-0439-9 .

Gregorio Alapont A, Lahuerta-Zamora L, Martínez Calatayud J. Indirect determination of paracetamol in pharmaceutical formulations by inhibition of the system luminol–H2O2–Fe(CN)6 3− chemiluminescence. J Pharm Biomed Anal. 1999;21:311–7. doi: 10.1016/s0731-7085(99)00124-7 .

British Pharmacopoeia 1993. HM stationery office. London; 1993. vol. II, p. 1043.

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem