Vapor phase penetration measurements with both single and double-pass Schlieren for the same injection event

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Vapor phase penetration measurements with both single and double-pass Schlieren for the same injection event

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Payri, Raul es_ES
dc.contributor.author Salvador Rubio, Francisco Javier es_ES
dc.contributor.author Bracho León, Gabriela Cristina es_ES
dc.contributor.author Viera Sotillo, Alberto Antonio es_ES
dc.date.accessioned 2018-05-09T09:29:48Z
dc.date.available 2018-05-09T09:29:48Z
dc.date.issued 2017-07-28
dc.identifier.isbn 9788490485804
dc.identifier.uri http://hdl.handle.net/10251/101594
dc.description.abstract [EN] Schlieren imaging has been adopted as a standard optical technique for the analysis of diesel sprays under engine like conditions. A single-pass Schlieren arrangement is typically used for the study of single-orifice nozzles, as vessels with multiple optical accesses regularly allow line of sight visualization. Contrarily, for multi-spray nozzles, measurements are commonly performed through a single optical access, in which case a double-pass arrangement is employed. As a consequence, the light beams pass through the test section twice, increasing the optical sensitivity of the Schlieren setup. However, the impact this has on the macroscopic spray characteristics is still unclear. The scope of this study is to analyze the differences in vapor phase penetration for the same injection event, through high-speed imaging, for both single and double-pass Schlieren configurations. Experiments were carried out with a three hole nozzle with a nominal orifice diameter of 90 µm, named Spray B from the Engine Combustion Network, using commercially available diesel fuel and in non-reactive conditions. The impact of different injection pressures and chamber densities on the spray captured by each setup was assessed. On the results, vapor phase penetration followed the expected trend found in the literature, as it increases with increasing injection pressure and decreasing chamber density. Comparing the optical setups, vapor phase penetration obtained with the double-pass arrangement was marginally higher. The deviation was observed throughout all tested conditions. Although the discrepancy was approximately constant for different injection pressures and chamber temperature, it increased with increasing density. These results highlight the importance of a proper understanding regarding the limitations of optical diagnostics, in particular for results used in calibration of computational models. es_ES
dc.description.sponsorship This research has been partially funded by FEDER and Spanish Ministerio de Economía y Competitividad through project TRA2015-67679-c2-1-R. Additionally, Alberto Viera is supported through the FPI contract 2016-S2-1361 of “Programa de Apoyo para la Investigación y Desarrollo (PAID)” of Universitat Poltècnica de València. es_ES
dc.format.extent 8 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Ilass Europe. 28th european conference on Liquid Atomization and Spray Systems es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Diesel injection es_ES
dc.subject Schlieren es_ES
dc.subject Vapor phase penetration es_ES
dc.title Vapor phase penetration measurements with both single and double-pass Schlieren for the same injection event es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/ILASS2017.2017.4884
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//TRA2015-67679-C2-1-R/ES/ESTUDIO DE LA INTERACCION CHORRO-PARED EN CONDICIONES REALISTAS DE MOTOR/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV//PAID2016-S2-1361/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario CMT-Motores Térmicos - Institut Universitari CMT-Motors Tèrmics es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Máquinas y Motores Térmicos - Departament de Màquines i Motors Tèrmics es_ES
dc.description.bibliographicCitation Payri, R.; Salvador Rubio, FJ.; Bracho León, GC.; Viera Sotillo, AA. (2017). Vapor phase penetration measurements with both single and double-pass Schlieren for the same injection event. En Ilass Europe. 28th european conference on Liquid Atomization and Spray Systems. Editorial Universitat Politècnica de València. 747-754. https://doi.org/10.4995/ILASS2017.2017.4884 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename ILASS2017 - 28th European Conference on Liquid Atomization and Spray Systems es_ES
dc.relation.conferencedate September 06-08,2017 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/ILASS/ILASS2017/paper/view/4884 es_ES
dc.description.upvformatpinicio 747 es_ES
dc.description.upvformatpfin 754 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\4884 es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.contributor.funder Universitat Politècnica de València es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem