Optimal design of a light commercial freezer through the analysis of the combined effects of capillary tube diameter and refrigerant charge on the performance

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Optimal design of a light commercial freezer through the analysis of the combined effects of capillary tube diameter and refrigerant charge on the performance

Mostrar el registro completo del ítem

Pisano, A.; Martínez-Ballester, S.; Corberán, JM.; Mauro, AW. (2015). Optimal design of a light commercial freezer through the analysis of the combined effects of capillary tube diameter and refrigerant charge on the performance. International Journal of Refrigeration. 52:1-10. https://doi.org/10.1016/j.ijrefrig.2014.12.023

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/102114

Ficheros en el ítem

Metadatos del ítem

Título: Optimal design of a light commercial freezer through the analysis of the combined effects of capillary tube diameter and refrigerant charge on the performance
Autor: Pisano, Alessandro Martínez-Ballester, Santiago Corberán, José M. Mauro, Alfonso William
Entidad UPV: Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada
Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica
Fecha difusión:
Resumen:
[EN] In this work, a discussion on a methodology to optimize the performance of a commercial freezer by using a simulation tool is presented. In order to provide a practical tool for deciding the best combination of ...[+]
Palabras clave: Freezer , Optimization , Capillary tube , Refrigerant charge , Numerical
Derechos de uso: Cerrado
Fuente:
International Journal of Refrigeration. (issn: 0140-7007 )
DOI: 10.1016/j.ijrefrig.2014.12.023
Editorial:
Elsevier
Versión del editor: http://doi.org/10.1016/j.ijrefrig.2014.12.023
Código del Proyecto:
info:eu-repo/grantAgreement/MICINN//DPI2011-23740/ES/DESARROLLO DE TECNICAS DE DIAGNOSTICO DE AVERIAS INCIPIENTES EN AEROGENERADORES, MEDIANTE EL ANALISIS TIEMPO-FRECUENCIA DE MAGNITUDES ELECTRICAS/
Agradecimientos:
This work was supported by the Spanish 'Ministerio de Ciencia e Innovacion' (MICINN) in the framework of the 'VI Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica 2008-2011' (Programa Nacional ...[+]