ACI (1989) Building code requirements for reinforced concrete (ACI 318-89). ACI Committee 318, American Concrete Institute, Farmington Hills, Michigan, USA
ACI (2008) Building code requirements for structural concrete (ACI 318-08) and commentary (318-08). ACI Committee 318, American Concrete Institute, Farmington Hills, Michigan, USA
ACI-ASCE (1991) Recommendations for design of beam-column connections in monolithic reinforced concrete structures (ACI 352R-91). Joint ACI-ASCE Committee 352, American Concrete Institute, Farmington Hills, Michigan, USA
[+]
ACI (1989) Building code requirements for reinforced concrete (ACI 318-89). ACI Committee 318, American Concrete Institute, Farmington Hills, Michigan, USA
ACI (2008) Building code requirements for structural concrete (ACI 318-08) and commentary (318-08). ACI Committee 318, American Concrete Institute, Farmington Hills, Michigan, USA
ACI-ASCE (1991) Recommendations for design of beam-column connections in monolithic reinforced concrete structures (ACI 352R-91). Joint ACI-ASCE Committee 352, American Concrete Institute, Farmington Hills, Michigan, USA
ACI-ASCE (2002) Recommendations for design of beam-column connections in monolithic reinforced concrete structures (ACI 352R-02). Joint ACI-ASCE Committee 352, American Concrete Institute, Farmington Hills, Michigan, USA
Arslan MH, Korkmaz HH (2007) What is to be learned from damage and failure of reinforced concrete structures during recent earthquakes in Turkey? Eng Fail Anal 14(1):1–22
ASCE (2007) Seismic Rehabilitation of Existing Buildings, ASCE/SEI 41-06. American Society of Civil Engineers, Reston
ASCE (2010) Minimum Design Loads for Building and Other Structures, ASCE/SEI 7-10. American Society of Civil Engineers, Reston
Benavent-Climent A (2007) Seismic behavior of RC side beam-column connections under dynamic loading. J Earthquake Eng 11:493–511
Benavent-Climent A, Zahran R (2010) An energy-based procedure for the assessment of seismic capacity of existing frames: application to RC wide beam systems in Spain. Soil Dyn Earthq Eng 30:354–367
Benavent-Climent A, Cahís X, Zahran R (2009) Exterior wide beam-column connections in existing RC frames subjected to lateral earthquake loads. Eng Struct 31:1414–1424
Benavent-Climent A, Cahís X, Vico JM (2010) Interior wide beam-column connections in existing RC frames subjected to lateral earthquake loading. Bull Earthq Eng 8:401–420
BHRC (2004) Iranian Code of Practice for Seismic Resistant Design of Buildings. Standard Nº 2800, 3rd edn. Building and Housing Research Center, Tehran
Borzi B, Elnashai AS (2000) Refined force reduction factors for seismic design. Eng Struct 22:1244–1260
Borzi B, Pinho R, Crowley H (2008) Simplified pushover-based vulnerability analysis for large-scale assessment of RC buildings. Eng Struct 30:804–820
BSI (2004) Eurocode 2: Design of concrete structures: Part 1-1: General rules and rules for buildings. British Standards Institutions, London
Calvi GM (1999) A displacement-based approach for vulnerability evaluation of classes of buildings. J Earthquake Eng 3(3):411–438
CDSC (1994) Seismic construction code, NCSR-94. Committee for the Development of Seismic Codes, Spanish Ministry of Construction, Madrid, Spain (in Spanish)
CDSC (2002) Seismic construction code, NCSE-02. Committee for the Development of Seismic Codes, Spanish Ministry of Construction, Madrid, Spain (in Spanish)
CEN (2004) Eurocode 8: design of structures for earthquake resistance—part 1: general rules, seismic actions and rules for buildings. European Standard EN 1998-1:2003—Comité Européen de Normalisation, Brussels, Belgium
CEN (2005) Eurocode 8: design of structures for earthquake resistance—part 3: assessment and retrofitting of buildings. European Standard EN 1998-1:2005—Comité Européen de Normalisation, Brussels, Belgium
Cheung PC, Paulay T, Park R (1991) Mechanisms of slab contributions in beam-column subassemblages. ACI Spec Publ 123
Cosenza E, Manfredi G, Polese M, Verderame GM (2005) A multilevel approach to the capacity assessment of existing RC buildings. J Earthquake Eng 9(1):1–22
Crowley H, Pinho R (2010) Revisiting Eurocode 8 formulae for periods of vibration and their employment in linear seismic analysis. Earthquake Eng Struct Dynam 39:223–235
CS.LL.PP (2009) Instructions for the application of the technique code for the Constructions. Official Gazette of the Italian Republic, 47, Regular Supplement no. 27 (in Italian)
De Luca F, Vamvatsikos D, Iervolino I (2013) Near-optimal piecewise linear fits of static pushover capacity curves for equivalent SDOF analysis. Earthquake Eng Struct Dynam 42(4):523–543
De Luca F, Verderame GM, Gómez-Martínez F, Pérez-García A (2014) The structural role played by masonry infills on RC building performances after the 2011 Lorca, Spain, earthquake. Bull Earthq Eng 12(5):1999–2026
Decanini LD, Mollaioli F (2000) Analisi di vulnerabilità sismica di edifici in cemento armato pre-normativa. In: Cosenza E (ed) Comportamento sismico di edifici in cemento armato progettati per carichi verticali. CNR—Gruppo Nazionale per la Difesa dei Terremoti, Rome (in Italian)
Dolšek M, Fajfar P (2004) IN2—a simple alternative for IDA. In: Proceedings of the 13th World conference on Earthquake Engineering. August 1–6, Vancouver, Canada. Paper 3353
Domínguez D, López-Almansa F, Benavent-Climent A (2014) Comportamiento para el terremoto de Lorca de 11-05-2011, de edificios de vigas planas proyectados sin tener en cuenta la acción sísmica. Informes de la Construcción 66(533):e008 (in Spanish)
Domínguez D, López-Almansa F, Benavent-Climent A (2016) Would RC wide-beam buildings in Spain have survived Lorca earthquake (11-05-2011)? Eng Struct 108:134–154
Dönmez C (2013) Seismic Performance of Wide-Beam Infill-Joist Block RC Frames in Turkey. J Perform Constr Facil 29(1):04014026
Fadwa I, Ali TA, Nazih E, Sara M (2014) Reinforced concrete wide and conventional beam-column connections subjected to lateral load. Eng Struct 76:34–48
Fardis MN (2009) Seismic design, assessment and retrofitting of concrete, Buildings edn. Springer, London
Gentry TR, Wight JK (1992) Reinforced concrete wide beam-column connections under earthquake-type loading. Report no. UMCEE 92-12. Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
Gómez-Martínez F (2015) FAST simplified vulnerability approach for seismic assessment of infilled RC MRF buildings and its application to the 2011 Lorca (Spain) earthquake. Ph.D. Thesis, Polytechnic University of Valencia, Spain
Gómez-Martínez F, Pérez García A, De Luca F, Verderame GM (2015a) Comportamiento de los edificios de HA con tabiquería durante el sismo de Lorca de 2011: aplicación del método FAST. Informes de la Construcción 67(537):e065 (in Spanish)
Gómez-Martínez F, Pérez-García A, Alonso Durá A, Martínez Boquera A, Verderame GM (2015b) Eficacia de la norma NCSE-02 a la luz de los daños e intervenciones tras el sismo de Lorca de 2011. In: Proceedings of Congreso Internacional sobre Intervención en Obras Arquitectónicas tras Sismo: L’Aquila (2009), Lorca (2011) y Emilia Romagna (2012), May 13–14, Murcia, Spain (in Spanish)
Gómez-Martínez F, Verderame GM, De Luca F, Pérez-García A, Alonso-Durá, A (2015c). High ductility seismic performances of wide-beam RC frames. In; XVI Convegno ANIDIS. September 13–17, L'Aquila, Italy
Hawkins NM, Mitchell D (1979) Progressive collapse of flat plate structures. ACI J 76(7):775–808
Iervolino I, Manfredi G, Polese M, Verderame GM, Fabbrocino G (2007) Seismic risk of RC building classes. Eng Struct 29(5):813–820
Inel M, Ozmen HB, Akyol E (2013) Observations on the building damages after 19 May 2011 Simav (Turkey) earthquake. Bull Earthq Eng 11(1):255–283
Kurose Y, Guimaraes GN, Zuhua L, Kreger ME, Jirsa JO (1991) Evaluation of slab-beam-column connections subjected to bidirectional loading. ACI Spec Publ 123:39–67
LaFave JM, Wight JK (1997) Behavior of reinforced exterior wide beam-column-slab connections subjected to lateral earthquake loading. Report no. UMCEE 97-01. Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
LaFave JM, Wight JK (1999) Reinforced concrete exterior wide beam-column-slab connections subjected to lateral earthquake loading. ACI Struct J 96(4):577–586
LaFave JM, Wight JK (2001) Reinforced concrete wide-beam construction vs. conventional construction: resistance to lateral earthquake loads. Earthq Spectra 17(3):479–505
Li B, Kulkarni SA (2010) Seismic behavior of reinforced concrete exterior wide beam-column joints. J Struct Eng (ASCE) 136(1):26–36
López-Almansa F, Domínguez D, Benavent-Climent A (2013) Vulnerability analysis of RC buildings with wide beams located in moderate seismicity regions. Eng Struct 46:687–702
Masi A, Santarsiero G, Nigro D (2013a) Cyclic tests on external RC beam-column joints: role of seismic design level and axial load value on the ultimate capacity. J Earthquake Eng 17(1):110–136
Masi A, Santarsiero G, Mossucca A, Nigro D (2013b) Seismic behaviour of RC beam-column subassemblages with flat beam. In: Proceedings of XV Convegno della Associazione Nazionale Italiana di Ingegneria Sismica, ANIDIS. Padova, Italy
Mazzolani FM, Piluso V (1997) Plastic design of seismic resistant steel frames. Earthquake Eng Struct Dynam 26:167–191
MEPP (2000a) Greek earthquake resistant design code, EAK 2000. Ministry of Environment, Planning and Public Works, Athens
MEPP (2000b) Greek code for the design and construction of concrete works, EKOS 2000. Ministry of Environment, Planning and Public Works, Athens (in Greek)
Miranda E, Bertero VV (1994) Evaluation of strength reduction factors for earthquake-resistant design. Earthq Spectra 10(2):357–379
MPWS (2007) Specifications for buildings to be built in seismic areas. Turkish Standards Institution, Ministry of Public Works and Settlement, Ankara (in Turkish)
Mwafy AM, Elnashai AS (2002) Calibration of force reduction factors of RC buildings. J Earthquake Eng 6(2):239–273
NZS (2004) Structural design actions. Part 5: earthquake actions, NZS 1170.5. New Zealand Standards, Wellington
NZS (2006) Concrete structures standard: part 1—the design of concrete structures, NZS 3101 part 1. New Zealand Standards, Wellington
Pan A, Moehle JP (1989) Lateral displacement ductility of reinforced concrete flat plates. ACI Struct J 86(3):250–258
Panagiotakos TB, Fardis MN (2001) Deformations of reinforced concrete members at yielding and ultimate. ACI Struct J 98(2):135–148 [and Appendix 1 (69 pp)]
Paulay T, Priestley MJN (1992) Seismic design of concrete and masonry structures. Wiley, New York, USA
Quintero-Febres CG, Wight JK (1997) Investigation on the seismic behavior of RC interior wide beam-column connections. Report no. UMCEE 97-15. Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
Quintero-Febres CG, Wight JK (2001) Experimental study of Reinforced concrete interior wide beam-column connections subjected to lateral loading. ACI Struct J 98(4):572–582
Serna-Ros P, Fernández-Prada MA, Miguel-Sosa P, Debb OAR (2001) Influence of stirrup distribution and support width on the shear strength of reinforced concrete wide beams. Mag Concr Res 54(00):1–11
Shuraim AB (2012) Transverse stirrup configurations in RC wide shallow beams supported on narrow columns. J Struct Eng 138(3):416–424
Siah WL, Stehle JS, Mendis P, Goldsworthy H (2003) Interior wide beam connections subjected to lateral earthquake loading. Eng Struct 25:281–291
Tore E, Demiral T (2014) A parametric study of code-based performance limits for wide beams. e-GFOS 5(8):1–11
Vamvatsikos D, Cornell CA (2002) Incremental Dynamic Analysis. Earthquake Eng Struct Dynam 31:491–514
Vidic T, Fajfar P, Fischinger M (1994) Consistent inelastic design spectra: strength and displacement. Earthquake Eng Struct Dynam 23:507–521
Vielma JC, Barbat AH, Oller S (2010) Seismic safety of low ductility structures used in Spain. Bull Earthq Eng 8:135–155
[-]