Push-out tests on demountable shear connectors of steel-concrete composite structures

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Push-out tests on demountable shear connectors of steel-concrete composite structures

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Kozma, Andras es_ES
dc.contributor.author Odenbreit, Chirstoph es_ES
dc.contributor.author Braun, Matthias es_ES
dc.contributor.author Veljkovic, Milan es_ES
dc.contributor.author Nijgh, Martin es_ES
dc.date.accessioned 2018-09-27T07:11:06Z
dc.date.available 2018-09-27T07:11:06Z
dc.date.issued 2018-06-05
dc.identifier.isbn 9788490486016
dc.identifier.uri http://hdl.handle.net/10251/108374
dc.description.abstract [EN] The deconstruction of steel-concrete composite structures in buildings and the later separation of the materials is a labour- and cost intensive work. This is due to the fact, that the shear studs are welded on the steel beam, and a large amount of cutting work gets necessary. As a result, recycling is difficult and the potential for reusing entire elements is lost. The carbon footprint of composite structures could be decreased by the application of the principles of “design for deconstruction and reuse”. This paper presents a study with its respective laboratory experiments on demountable shear connectors that facilitate recyclability and even offer the potential for reusing elements in their entirety. In the Laboratory of Steel and Composite Structures of the University of Luxembourg 15 push-out tests have been carried out using different bolted connection systems suitable for multiple uses in order to verify their performance characteristics by means of shear strength, stiffness, slip capacity, ductility and ability of demounting. The investigated systems included pre-stressed and epoxy resin injection bolts, solid slabs and composite slabs with profiled decking. The results showed that the tested demountable shear connections could provide higher shear resistance than conventional shear connections in some cases. The connection failure happened in the bolts, while there was no or minor visible damage observed on the connected members. Most of the tested connections could fulfil the ductility requirement given by Eurocode 4. The application of epoxy resin in the hole clearance resulted in lower slip capacity. The outcome will provide an important basis for the calibration of the forthcoming enhancement and numerical simulation of the demountable shear connections. The failure behaviour, the observed damages and the resulting ability of the elements for later re-use are discussed in detail. es_ES
dc.description.sponsorship The research leading to these results is a part of a common project of Steel Construction Institute, University of Luxembourg, University of Bradford, Lindab, Tata Steel, Bouwen met Staal, Delft University of Technology and AEC3. The project has received funding from the Research Fund for Coal and Steel under grant agreement No 710040. es_ES
dc.format.extent 8 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018 es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Demountable shear connectors es_ES
dc.subject Push-out tests es_ES
dc.subject Metal decking es_ES
dc.subject Circular economy es_ES
dc.subject Shear capacity es_ES
dc.subject Experimental study es_ES
dc.title Push-out tests on demountable shear connectors of steel-concrete composite structures es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/ASCCS2018.2018.7155
dc.relation.projectID info:eu-repo/grantAgreement/RFCS//710040/
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Kozma, A.; Odenbreit, C.; Braun, M.; Veljkovic, M.; Nijgh, M. (2018). Push-out tests on demountable shear connectors of steel-concrete composite structures. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 549-556. https://doi.org/10.4995/ASCCS2018.2018.7155 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018 es_ES
dc.relation.conferencedate Junio 27-29,2018 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/7155 es_ES
dc.description.upvformatpinicio 549 es_ES
dc.description.upvformatpfin 556 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\7155 es_ES
dc.contributor.funder Research Fund for Coal and Steel