Influence of steel tube thickness and concrete strength on the axial capacity of stub CFST columns

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Influence of steel tube thickness and concrete strength on the axial capacity of stub CFST columns

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Ibáñez Usach, Carmen es_ES
dc.contributor.author Hernández-Figueirido, David es_ES
dc.contributor.author Piquer Vicent, Ana es_ES
dc.date.accessioned 2018-10-01T07:21:31Z
dc.date.available 2018-10-01T07:21:31Z
dc.date.issued 2018-06-05
dc.identifier.isbn 9788490486016
dc.identifier.uri http://hdl.handle.net/10251/108733
dc.description.abstract [EN] In order to study the mechanical response of concrete-filled steel tubular (CFST) columns, several experimental and theoretical studies have been conducted in the last years. However, the influence of thin-walled steel tubes on the axial capacity of these composite columns is not completely stablished, especially when it is combined with high-strength concrete as infill. In this paper, the results of an experimental campaign on 9 concrete-filled steel tubular stub columns subjected to concentric load are presented. Different cross-section shapes are considered in this campaign, i.e. circular, square and rectangular. The influence of the steel tube wall thickness is analysed by including in the tests specimens with thin-walled tubes, whose behaviour needs to be studied in depth given the issues arising when working under compression. The experimental program is designed so the analysis of the results permits to drawn consistent conclusions. For each series, the steel tube thickness is the only geometric parameter modified in order to properly study its effect. Besides, two different concrete strengths were considered for the concrete infill, i.e. normal and high- strength concrete, to observe their effect on the ultimate capacity of the columns. During the tests, the specimens are subjected to axial load and the evolution of the axial displacement with the load is registered. The ultimate capacity of each specimen is obtained and an analysis of the steel tube thickness and concrete strength influence is accomplished. Finally, the study of the dependency of the failure mode on these parameters is carried out. es_ES
dc.description.sponsorship The authors would like to express their gratitude to Universitat Jaume I for the project P1-1A2015-06. es_ES
dc.format.extent 5 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018 es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Stub columns es_ES
dc.subject Concrete-filled steel tubes es_ES
dc.subject High strength concrete es_ES
dc.subject Sectional capacity es_ES
dc.subject Strength index es_ES
dc.subject Concrete contribution ratio es_ES
dc.subject.classification MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS es_ES
dc.title Influence of steel tube thickness and concrete strength on the axial capacity of stub CFST columns es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/ASCCS2018.2018.7196
dc.relation.projectID info:eu-repo/grantAgreement/UJI//PI-IA2015-06/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ciencia y Tecnología del Hormigón - Institut de Ciència i Tecnologia del Formigó es_ES
dc.description.bibliographicCitation Ibáñez Usach, C.; Hernández-Figueirido, D.; Piquer Vicent, A. (2018). Influence of steel tube thickness and concrete strength on the axial capacity of stub CFST columns. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 253-257. https://doi.org/10.4995/ASCCS2018.2018.7196 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018 es_ES
dc.relation.conferencedate Junio 27-29,2018 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/7196 es_ES
dc.description.upvformatpinicio 253 es_ES
dc.description.upvformatpfin 257 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\7196 es_ES
dc.contributor.funder Universitat Jaume I es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)