The effect of damage location on the performance of seismically damaged concrete filled steel tube columns at fire

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

The effect of damage location on the performance of seismically damaged concrete filled steel tube columns at fire

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Talebi, Elnaz es_ES
dc.contributor.author Korzen, Manfred es_ES
dc.contributor.author Espinós, Ana es_ES
dc.contributor.author Hothan, Sascha es_ES
dc.date.accessioned 2018-10-02T06:19:50Z
dc.date.available 2018-10-02T06:19:50Z
dc.date.issued 2018-06-05
dc.identifier.isbn 9788490486016
dc.identifier.uri http://hdl.handle.net/10251/108884
dc.description.abstract [EN] In this paper, a nonlinear three-dimensional finite element (FE) model was developed and validated to study the effect of seismic damage location on the response of concrete filled tube (CFT) columns at fire after earthquakes. Three analyses were conducted consecutively in the modelling, namely, cyclic, thermal and structural. Results of the cyclic loading analysis comprising residual deformations were applied as the initial condition to the thermal-stress model, replicating the seismic performance of column. Following, a nonlinear sequentially coupled-thermal stress analysis was carried out to investigate the fire response of CFT columns after the seismic event. Three damage scenarios were contemplated, considering any possible potential damages that could be generated by the earthquake loading on CFT columns. The accuracy of proposed FE model was examined by comparing the numerical results with that of available tests on fire and cyclic loading. By means of validated model, the performance of damaged CFT columns was then investigated under fire after earthquakes. The level of damage was assumed as a high damage level, presuming that the column reached 50% of its lateral resistance while still maintaining its overall stability after the earthquake. The results were presented broadly, including the axial deformation history as well as the fire resistance time for CFT columns. To have a comprehensive insight on the influence of damage location in columns, the fire response of damaged specimens was compared with that of an intact one. es_ES
dc.description.sponsorship The research presented in this paper is based on the work funded by Alexander von Humboldt (AvH) foundation under a postdoctoral award scheme. This support is greatly appreciated. es_ES
dc.format.extent 8 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018 es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Fire after earthquake es_ES
dc.subject Concrete filled tube (CFT) column es_ES
dc.subject Finite element model es_ES
dc.subject Seismically damaged column es_ES
dc.subject Damage location es_ES
dc.subject Fire performance es_ES
dc.title The effect of damage location on the performance of seismically damaged concrete filled steel tube columns at fire es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/ASCCS2018.2018.6984
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Talebi, E.; Korzen, M.; Espinós, A.; Hothan, S. (2018). The effect of damage location on the performance of seismically damaged concrete filled steel tube columns at fire. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 835-844. https://doi.org/10.4995/ASCCS2018.2018.6984 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018 es_ES
dc.relation.conferencedate Junio 27-29,2018 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/6984 es_ES
dc.description.upvformatpinicio 835 es_ES
dc.description.upvformatpfin 844 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\6984 es_ES
dc.contributor.funder Alexander von Humboldt Foundation


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem