Analysis of slab-column connections in CFT sections without continuity of the tube

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Analysis of slab-column connections in CFT sections without continuity of the tube

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Albareda-Valls, Albert es_ES
dc.contributor.author Milan, Caio es_ES
dc.contributor.author Maristany Carreras, Jordi es_ES
dc.contributor.author Garcia Carrera, David es_ES
dc.date.accessioned 2018-10-02T06:53:20Z
dc.date.available 2018-10-02T06:53:20Z
dc.date.issued 2018-06-05
dc.identifier.isbn 9788490486016
dc.identifier.uri http://hdl.handle.net/10251/108892
dc.description.abstract [EN] When dealing with concrete-filled tube columns and RC slabs, it is usual to interrupt steel tubes in slab-column connections if the column is mainly compressed. Contractors do prefer to solve these connections with independent tubes, although innerreinforcements may be continuous through the slab. In these cases, both tubes from the upper and lower levels do have base plate connections, with a set of anchor bolts. This procedure saves a lot of time of global works, by making everything easier at the same time, as tubular profiles do not intersect the formwork.However, this reasonable design for slab-column joints suggest at least some questions about the strength of the concrete at the area of connection, where the tube has been interrupted. On the one hand, the load is transferred through concrete in the slab thickness, since there is no continuity of the tube; on the other hand, concrete at that point becomes triaxially confined due to the restriction to lateral deformation.This study analyses the validity of this connection method and the differences observed depending on the relative location of the column (corner, façade –lateral- or central pillars). Needless to say that the relative location of the column leads to differentconfinement patterns in concrete. es_ES
dc.format.extent 5 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018 es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Concrete-filled tubes es_ES
dc.subject Slab-column connections es_ES
dc.subject Confinement effect es_ES
dc.title Analysis of slab-column connections in CFT sections without continuity of the tube es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/ASCCS2018.2018.7152
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Albareda-Valls, A.; Milan, C.; Maristany Carreras, J.; Garcia Carrera, D. (2018). Analysis of slab-column connections in CFT sections without continuity of the tube. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 507-511. https://doi.org/10.4995/ASCCS2018.2018.7152 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018 es_ES
dc.relation.conferencedate Junio 27-29,2018 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/7152 es_ES
dc.description.upvformatpinicio 507 es_ES
dc.description.upvformatpfin 511 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\7152 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem