- -

Shear connection requirements for composite cellular beams

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Shear connection requirements for composite cellular beams

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Aggelopoulos, Eleftherios es_ES
dc.contributor.author Hanus, Francois es_ES
dc.contributor.author Lawson, Mark es_ES
dc.date.accessioned 2018-10-04T07:09:40Z
dc.date.available 2018-10-04T07:09:40Z
dc.date.issued 2018-06-05
dc.identifier.isbn 9788490486016
dc.identifier.uri http://hdl.handle.net/10251/109218
dc.description.abstract [EN] Beams with regular circular web openings (cellular beams) are often used in composite construction. Rules for the minimum degree of shear connection in composite beams are presented in Eurocode 4 but were derived for solid web beams in propped construction. This paper investigates the degree of shear connection requirements for composite cellular beams, focusing on the combined effect of using a steel section with regularly spaced, large circular web openings and unpropped construction conditions. The effect of the diameter and the spacing of the openings is also investigated. In order to provide rules for the minimum degree of shear connection in cellular beams, parametric finite element (FE) analyses were carried out for beams in the span range of 9 to 18 m. The results were calibrated against a 15.3 m span composite cellular beam test with a low degree of shear connection. The proposed minimum degree of shear connection requirements for beams with regular circular web openings are presented for both propped and unpropped construction, and for symmetric and asymmetric steel sections. Comparisons are made with equivalent beams with solid webs (no openings) and it is shown that significant relaxation in the codified minimum degree of shear connection to the current version of Eurocode 4 can be justified for composite cellular beams. es_ES
dc.format.extent 7 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018 es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Beams and girders es_ES
dc.subject Buildings es_ES
dc.subject Structures and design es_ES
dc.subject Codes of practice and standards es_ES
dc.subject Composite structures es_ES
dc.title Shear connection requirements for composite cellular beams es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/ASCCS2018.2018.7161
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Aggelopoulos, E.; Hanus, F.; Lawson, M. (2018). Shear connection requirements for composite cellular beams. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 153-159. https://doi.org/10.4995/ASCCS2018.2018.7161 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018 es_ES
dc.relation.conferencedate Junio 27-29,2018 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/7161 es_ES
dc.description.upvformatpinicio 153 es_ES
dc.description.upvformatpfin 159 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\7161 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem