Fire performance of concrete-encased CFST columns and beam-column joints

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Zhou, Kan es_ES
dc.contributor.author Han, Lin-Han es_ES
dc.date.accessioned 2018-10-04T07:29:59Z
dc.date.available 2018-10-04T07:29:59Z
dc.date.issued 2018-06-05
dc.identifier.isbn 9788490486016
dc.identifier.uri http://hdl.handle.net/10251/109237
dc.description.abstract [EN] Concrete-encased CFST (concrete filled steel tube) structure is a type of composite structure featuring an inner CFST component and an outer reinforced concrete (RC) component. They are gaining popularity in high-rise buildings and large-span buildings in China nowadays. To date, the behaviour of concrete-encased CFST structures at ambient temperature has been investigated, but their fire performance has seldom been addressed, including the performance in fire and after exposure to fire. This paper summarizes the fire test results of concrete-encased CFST columns and beam-column joints. The cruciform beam-column joint was composed of one continuous concrete-encased CFST column and two cantilevered reinforced concrete (RC) beams. These specimens were subjected to a combined effect of load and full-range fire. The test procedure included four phases, i.e. a loading phase at ambient temperature, a standard fire exposure phase with constant load applied, a sequential cooling phase and a postfire loading phase. The main findings are presented and analysed. Two types of failure were identified, i.e. the failure during fire exposure and the failure during postfire loading. Global buckling failure was observed for all the column specimens. The column specimens with common load ratios achieved high fire ratings without additional fire protection. The concrete-encased CFST columns also retained high postfire residual strength. As for the joint members, beam failure was observed in all cases. The measured temperature-time history and deformation-time history are also presented and discussed. For both the column and joint specimens, the deformation over the cooling phase was significantly greater than that in the standard fire exposure phase. es_ES
dc.format.extent 8 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018 es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Concrete-encased es_ES
dc.subject Concrete filled steel tube (CFST) es_ES
dc.subject Reinforced concrete (RC) es_ES
dc.subject Composite columns es_ES
dc.subject Fire resistance es_ES
dc.subject Postfire residual strength es_ES
dc.title Fire performance of concrete-encased CFST columns and beam-column joints es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/ASCCS2018.2018.6927
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Zhou, K.; Han, L. (2018). Fire performance of concrete-encased CFST columns and beam-column joints. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 779-786. https://doi.org/10.4995/ASCCS2018.2018.6927 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018 es_ES
dc.relation.conferencedate Junio 27-29,2018 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/6927 es_ES
dc.description.upvformatpinicio 779 es_ES
dc.description.upvformatpfin 786 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\6927 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)