dc.contributor.author Pascual, Ana Maria es_ES
dc.contributor.author Kuhlmann, Ulrike es_ES
dc.contributor.author Ruopp, Jakob es_ES
dc.contributor.author Stempniewski, L. es_ES
dc.date.accessioned 2018-10-10T07:04:44Z
dc.date.available 2018-10-10T07:04:44Z
dc.date.issued 2018-06-05
dc.identifier.isbn 9788490486016
dc.identifier.uri http://hdl.handle.net/10251/109990
dc.description.abstract [EN] The capacity of the headed studs when they are close to the edge may be limited by the splitting forces in the concrete. In the Eurocode 4 Part 2 Annex C the shear capacity under this particular arrangement of the studs, which is directly dependent on the distance to the edge, is formulated. In addition, the geometrical restrictions to prevent the failure by pull-out of the studs are also given in clause C1 (2). These rules are based on push-out tests for the edge position where tension forces in the lying studs spread over the width of the specimen in this unfavorable way. Nonetheless, the current limits lead to extremely long studs and represent a severe restriction, and on the other hand, it is still an open question whether in real buildings or bridge girders the tension stresses that produce the pull-out appears in the same way as in the push out tests. In this paper the revision of these restrictions is presented together with a research for the alternative use of EN 1992-4 plus RFCS Project INFASO for the verification of the tension loads on the studs. es_ES
dc.format.extent 6 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018 es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Headed studs es_ES
dc.subject Splitting forces es_ES
dc.subject Pull-out; edge position es_ES
dc.subject Shear capacity es_ES
dc.title Headed studs close to concrete edge under pull-out es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/ASCCS2018.2018.7151
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Pascual, AM.; Kuhlmann, U.; Ruopp, J.; Stempniewski, L. (2018). Headed studs close to concrete edge under pull-out. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 435-440. https://doi.org/10.4995/ASCCS2018.2018.7151 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018 es_ES
dc.relation.conferencedate Junio 27-29,2018 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/7151 es_ES
dc.description.upvformatpinicio 435 es_ES
dc.description.upvformatpfin 440 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\7151 es_ES