dc.description.abstract | [EN] The capacity of the headed studs when they are close to the edge may be limited by the splitting forces in the concrete. In the Eurocode 4 Part 2 Annex C the shear capacity under this particular arrangement of the studs, which is directly dependent on the distance to the edge, is formulated. In addition, the geometrical restrictions to prevent the failure by pull-out of the studs are also given in clause C1 (2). These rules are based on push-out tests for the edge position where tension forces in the lying studs spread over the width of the specimen in this unfavorable way. Nonetheless, the current limits lead to extremely long studs and represent a severe restriction, and on the other hand, it is still an open question whether in real buildings or bridge girders the tension stresses that produce the pull-out appears in the same way as in the push out tests. In this paper the revision of these restrictions is presented together with a research for the alternative use of EN 1992-4 plus RFCS Project INFASO for the verification of the tension loads on the studs. | es_ES |
dc.format.extent | 6 | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Editorial Universitat Politècnica de València | es_ES |
dc.relation.ispartof | Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018 | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Headed studs | es_ES |
dc.subject | Splitting forces | es_ES |
dc.subject | Pull-out; edge position | es_ES |
dc.subject | Shear capacity | es_ES |
dc.title | Headed studs close to concrete edge under pull-out | es_ES |
dc.type | Capítulo de libro | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.identifier.doi | 10.4995/ASCCS2018.2018.7151 | |
dc.rights.accessRights | Abierto | es_ES |
dc.description.bibliographicCitation | Pascual, AM.; Kuhlmann, U.; Ruopp, J.; Stempniewski, L. (2018). Headed studs close to concrete edge under pull-out. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 435-440. https://doi.org/10.4995/ASCCS2018.2018.7151 | es_ES |
dc.description.accrualMethod | OCS | es_ES |
dc.relation.conferencename | 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018 | es_ES |
dc.relation.conferencedate | Junio 27-29,2018 | es_ES |
dc.relation.conferenceplace | Valencia, Spain | es_ES |
dc.relation.publisherversion | http://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/7151 | es_ES |
dc.description.upvformatpinicio | 435 | es_ES |
dc.description.upvformatpfin | 440 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.relation.pasarela | OCS\7151 | es_ES |