- -

Acerca de la Influencia del tamaño de la muestra en el valor del coeficiente de absorción sonora en cámara reverberante según la Norma ISO 354

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Acerca de la Influencia del tamaño de la muestra en el valor del coeficiente de absorción sonora en cámara reverberante según la Norma ISO 354

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Gómez Lozano, Vicente es_ES
dc.contributor.author Arosemena Torbay, Xavier Antonio es_ES
dc.date.accessioned 2019-10-14T14:13:52Z
dc.date.available 2019-10-14T14:13:52Z
dc.date.created 2019-09-23
dc.date.issued 2019-10-14 es_ES
dc.identifier.uri http://hdl.handle.net/10251/128225
dc.description.abstract [ES] La determinación del coeficiente de absorción sonora de una muestra, de acuerdo a la Norma ISO 354, se realiza midiendo en primera instancia el tiempo de reverberación promedio en una cámara reverberante con un volumen mínimo de 150 m3 con y sin una muestra de ensayo rectangular de superficie entre 10 m2 y 12 m2 en un rango de frecuencias establecidos en la Norma ISO 266, utilizando los métodos de la señal de ruido interrumpida y de la respuesta impulsiva integrada. El área de absorción sonora equivalente se calcula a partir del tiempo de reverberación medido teniendo como límite los valores establecidos en la Tabla 1 de la Norma ISO 354, y permite determinar el coeficiente de absorción de las muestras estudiadas. Dependiendo de una serie de variables tales como el tamaño y colocación de la muestra dentro de la cámara reverberante, las medidas del tiempo de reverberación y en consecuencia del coeficiente de absorción sonora se ven afectadas, por lo cual la Norma ISO 354 puede estar sujeta a modificaciones y ajustes. Por ende se propone introducir muestras con superficies diferentes a aquellas establecidas en la Norma a distintas distancias y ángulos de incidencia con respecto a la envolvente del recinto y a las fuentes sonoras con la finalidad de estudiar los efectos que estas tienen últimamente en el coeficiente de absorción sonora de cada muestra. es_ES
dc.description.abstract [EN] The determination of the sound absorption coefficient of a sample, according to ISO Standard 354, is done by first measuring the average reverberation time in a reverberant chamber with a minimum volume of 150 m3 with and without a rectangular test sample of surface between 10 m2 and 12 m2 in a range of frequencies established in ISO 266, using the methods of the interrupted noise signal and the integrated impulse response. The equivalent sound absorption area is calculated from the reverberation time measured, having as a limit the values established in Table 1 of ISO Standard 354, and allows to determine the absorption coefficient of the samples studied. Depending on a series of variables such as the size and placement of the sample within the reverberant chamber, the measurements of the reverberation time and consequently of the sound absorption coefficient are affected, so that ISO Standard 354 may be subject to modifications and adjustments. Therefore, it is proposed to introduce samples with surfaces different from those established in the Standard at different distances and angles of incidence with respect to the enclosure of the enclosure and the sound sources in order to study the effects that these have lately on the coefficient of sound absorption of each sample. es_ES
dc.format.extent 91 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Acústica arquitectónica es_ES
dc.subject Sonido, Medición es_ES
dc.subject Sonido, Transmisión es_ES
dc.subject Architectural acoustics es_ES
dc.subject Sound, Measurament es_ES
dc.subject Sound, Transmission es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.other Máster Universitario en Edificación-Màster Universitari en Edificació es_ES
dc.title Acerca de la Influencia del tamaño de la muestra en el valor del coeficiente de absorción sonora en cámara reverberante según la Norma ISO 354 es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Gestión en la Edificación - Escola Tècnica Superior de Gestió en l'Edificació es_ES
dc.description.bibliographicCitation Arosemena Torbay, XA. (2019). Acerca de la Influencia del tamaño de la muestra en el valor del coeficiente de absorción sonora en cámara reverberante según la Norma ISO 354. http://hdl.handle.net/10251/128225 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\110053 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem