Measurement of the black globe temperature to estimate the MRT and WBGT indices using a smaller diameter globe than a standardized one: Experimental analysis

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Measurement of the black globe temperature to estimate the MRT and WBGT indices using a smaller diameter globe than a standardized one: Experimental analysis

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Vargas Salgado, Carlos Afranio es_ES
dc.contributor.author Chiñas Palacios, Cristian Daniel es_ES
dc.contributor.author Águila León, Jesús es_ES
dc.contributor.author Alfonso Solar, David es_ES
dc.date.accessioned 2019-12-03T13:26:46Z
dc.date.available 2019-12-03T13:26:46Z
dc.date.issued 2019-10-24
dc.identifier.isbn 9788490487891
dc.identifier.uri http://hdl.handle.net/10251/132198
dc.description.abstract [EN] Heat stress can affect negatively human performance, behavior and even health, therefore, mean radiant temperature (MRT) and wet-bulb globe temperature (WBGT) measurement and monitoring should be obtained for any environment in which people are constantly exposed. The aim of this work is to compare the globe thermometer temperature (tg), used for calculating both MTR and WBGT, using a smaller globe compared to a standardized diameter. For such purpose, a prototype has been designed. The device consists of an Arduino MEGA board, three temperature sensors, two black globes (Copper globe, matt black painted) and an anemometer. As an effort to use a device with a globe easier to handle in a real measuring device, a 9 cm diameter globe has been used which has a smaller diameter than a standardized one (15 cm); the third temperature sensor is used to measure the air temperature. MRT monitoring tests were carried out using the proposed prototype, collected data were compared between the smaller and the standardized diameter globes measurements according to UNE EN ISO 7723 and NTP 322 recommendations. Results of this work show that it is possible to use a smaller diameter globe in a heat stress monitor, with an acceptable margin of error compared to a standardized size globe. es_ES
dc.description.sponsorship This work was supported by the European Commission through GROW GREEN project (Agreement number: 730283 — GROW GREEN — H2020-SCC-2016-2017/H2020-SCCNBS-2stage-2016. http://growgreenproject.eu/)
dc.format.extent 7 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Proceedings 5th CARPE Conference: Horizon Europe and beyond
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Heat stress monitor es_ES
dc.subject Globe temperature es_ES
dc.subject MRT es_ES
dc.subject Arduino es_ES
dc.title Measurement of the black globe temperature to estimate the MRT and WBGT indices using a smaller diameter globe than a standardized one: Experimental analysis es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/CARPE2019.2019.10203
dc.relation.projectID info:eu-repo/grantAgreement/EC/H2020/730283/EU/Green Cities for Climate and Water Resilience, Sustainable Economic Growth, Healthy Citizens and Environments/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica es_ES
dc.description.bibliographicCitation Vargas Salgado, CA.; Chiñas Palacios, CD.; Águila León, J.; Alfonso Solar, D. (2019). Measurement of the black globe temperature to estimate the MRT and WBGT indices using a smaller diameter globe than a standardized one: Experimental analysis. En Proceedings 5th CARPE Conference: Horizon Europe and beyond. Editorial Universitat Politècnica de València. 201-207. https://doi.org/10.4995/CARPE2019.2019.10203 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename CARPE Conference 2019: Horizon Europe and beyond es_ES
dc.relation.conferencedate Octubre 23-25,2019 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/CARPE/CARPE2019/paper/view/10203 es_ES
dc.description.upvformatpinicio 201 es_ES
dc.description.upvformatpfin 207 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\10203 es_ES
dc.contributor.funder European Commission


Este ítem aparece en la(s) siguiente(s) colección(ones)