- -

Improving the computational effort of set-inversion-based prandial insulin delivery for its integration in insulin pumps

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Improving the computational effort of set-inversion-based prandial insulin delivery for its integration in insulin pumps

Mostrar el registro completo del ítem

León-Vargas, F.; Calm, R.; Bondía Company, J.; Vehí, J. (2012). Improving the computational effort of set-inversion-based prandial insulin delivery for its integration in insulin pumps. Journal of Diabetes Science and Technology. 6(6):1420-1428. https://doi.org/10.1177/193229681200600623

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/140828

Ficheros en el ítem

Metadatos del ítem

Título: Improving the computational effort of set-inversion-based prandial insulin delivery for its integration in insulin pumps
Autor: León-Vargas, Fabián Calm, Remei Bondía Company, Jorge Vehí, Josep
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica
Fecha difusión:
Resumen:
[EN] Objective: Set-inversion-based prandial insulin delivery is a new model-based bolus advisor for postprandial glucose control in type 1 diabetes mellitus (T1DM). It automatically coordinates the values of basal-bolus ...[+]
Palabras clave: Bolus advisor , Embedded algorithm , Optimized computation , Smart insulin pump
Derechos de uso: Cerrado
Fuente:
Journal of Diabetes Science and Technology. (issn: 1932-2968 )
DOI: 10.1177/193229681200600623
Editorial:
SAGE Publications
Versión del editor: https://doi.org/10.1177/193229681200600623
Código del Proyecto:
info:eu-repo/grantAgreement/Generalitat de Catalunya/Grups de Recerca Reconeguts per la Generalitat de Catalunya SGR 2009-2013/2009 SGR 523/ES/AEDS: AUTOMATION ENGINEERING AND DECISION SUPPORT SYSTEMS/
info:eu-repo/grantAgreement/MICINN//DPI2010-20764-C02-01/ES/NUEVAS ESTRATEGIAS DE CONTROL GLUCEMICO POSTPRANDIAL MEDIANTE TERAPIA CON BOMBA DE INSULINA EN DIABETES TIPO 1/
Agradecimientos:
This work was partially supported by the Spanish Ministry of Science and Innovation through Grant DPI-2010-20764-C02 and by the Autonomous Government of Catalonia through Grant SGR 523. Fabian León-Vargas ...[+]
Tipo: Artículo

References

Shetty, G., & Wolpert, H. (2010). Insulin Pump Use in Adults with Type 1 Diabetes—Practical Issues. Diabetes Technology & Therapeutics, 12(S1), S-11-S-16. doi:10.1089/dia.2010.0002

Pickup, J. (2002). Glycaemic control with continuous subcutaneous insulin infusion compared with intensive insulin injections in patients with type 1 diabetes: meta-analysis of randomised controlled trials. BMJ, 324(7339), 705-705. doi:10.1136/bmj.324.7339.705

Bell, MB, FACE, D. S. H., & Ovalle, MD, F. (2000). IMPROVED GLYCEMIC CONTROL WITH USE OF CONTINUOUS SUBCUTANEOUS INSULIN INFUSION COMPARED WITH MULTIPLE INSULIN INJECTION THERAPY. Endocrine Practice, 6(5), 357-360. doi:10.4158/ep.6.5.357 [+]
Shetty, G., & Wolpert, H. (2010). Insulin Pump Use in Adults with Type 1 Diabetes—Practical Issues. Diabetes Technology & Therapeutics, 12(S1), S-11-S-16. doi:10.1089/dia.2010.0002

Pickup, J. (2002). Glycaemic control with continuous subcutaneous insulin infusion compared with intensive insulin injections in patients with type 1 diabetes: meta-analysis of randomised controlled trials. BMJ, 324(7339), 705-705. doi:10.1136/bmj.324.7339.705

Bell, MB, FACE, D. S. H., & Ovalle, MD, F. (2000). IMPROVED GLYCEMIC CONTROL WITH USE OF CONTINUOUS SUBCUTANEOUS INSULIN INFUSION COMPARED WITH MULTIPLE INSULIN INJECTION THERAPY. Endocrine Practice, 6(5), 357-360. doi:10.4158/ep.6.5.357

Chase, H. P., Saib, S. Z., MacKenzie, T., Hansen, M. M., & Garg, S. K. (2002). Post-prandial glucose excursions following four methods of bolus insulin administration in subjects with Type 1 diabetes. Diabetic Medicine, 19(4), 317-321. doi:10.1046/j.1464-5491.2002.00685.x

Zisser, H., Wagner, R., Pleus, S., Haug, C., Jendrike, N., Parkin, C., … Freckmann, G. (2010). Clinical Performance of Three Bolus Calculators in Subjects with Type 1 Diabetes Mellitus: A Head-to-Head-to-Head Comparison. Diabetes Technology & Therapeutics, 12(12), 955-961. doi:10.1089/dia.2010.0064

Wang, Y., Percival, M. W., Dassau, E., Zisser, H. C., Jovanovič, L., & Doyle, F. J. (2009). A Novel Adaptive Basal Therapy Based on the Value and Rate of Change of Blood Glucose. Journal of Diabetes Science and Technology, 3(5), 1099-1108. doi:10.1177/193229680900300513

Bondia, J., Dassau, E., Zisser, H., Calm, R., Vehí, J., Jovanovič, L., & Doyle, F. J. (2009). Coordinated Basal—Bolus Infusion for Tighter Postprandial Glucose Control in Insulin Pump Therapy. Journal of Diabetes Science and Technology, 3(1), 89-97. doi:10.1177/193229680900300110

Revert, A., Calm, R., Vehi, J., & Bondia, J. (2011). Calculation of the Best Basal–Bolus Combination for Postprandial Glucose Control in Insulin Pump Therapy. IEEE Transactions on Biomedical Engineering, 58(2), 274-281. doi:10.1109/tbme.2010.2058805

Revert, A., Rossetti, P., Calm, R., Vehí, J., & Bondia, J. (2010). Combining Basal-Bolus Insulin Infusion for Tight Postprandial Glucose Control: An in Silico Evaluation in Adults, Children, and Adolescents. Journal of Diabetes Science and Technology, 4(6), 1424-1437. doi:10.1177/193229681000400617

Calm, R., García-Jaramillo, M., Bondia, J., Sainz, M. A., & Vehí, J. (2011). Comparison of interval and Monte Carlo simulation for the prediction of postprandial glucose under uncertainty in type 1 diabetes mellitus. Computer Methods and Programs in Biomedicine, 104(3), 325-332. doi:10.1016/j.cmpb.2010.08.008

Zisser, H. C., Bevier, W., Dassau, E., & Jovanovič, L. (2010). Siphon Effects on Continuous Subcutaneous Insulin Infusion Pump Delivery Performance. Journal of Diabetes Science and Technology, 4(1), 98-103. doi:10.1177/193229681000400112

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem