A simple robust method for estimating the glucose rate of appearance from mixed meals

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

A simple robust method for estimating the glucose rate of appearance from mixed meals

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Herrero, P. es_ES
dc.contributor.author Bondía Company, Jorge es_ES
dc.contributor.author Palerm, C.C. es_ES
dc.contributor.author Vehí, J. es_ES
dc.contributor.author Georgiou, P. es_ES
dc.contributor.author Oliver, N. es_ES
dc.contributor.author Toumazou, C. es_ES
dc.date.accessioned 2020-04-17T12:49:07Z
dc.date.available 2020-04-17T12:49:07Z
dc.date.issued 2012-01-01 es_ES
dc.identifier.issn 1932-2968 es_ES
dc.identifier.uri http://hdl.handle.net/10251/140869
dc.description.abstract [EN] Background: Estimating the rate of glucose appearance (Ra) after ingestion of a mixed meal may be highly valuable in diabetes management. The gold standard technique for estimating Ra is the use of a multitracer oral glucose protocol. However, this technique is complex and is usually not convenient for large studies. Alternatively, a simpler approach based on the glucose-insulin minimal model is available. The main drawback of this last approach is that it also requires a gastrointestinal model, something that may lead to identifiability problems. Methods: In this article, we present an alternative, easy-to-use method based on the glucose-insulin minimal model for estimation of Ra. This new technique avoids complex experimental protocols by only requiring data from a standard meal tolerance test. Unlike other model-based approaches, this new approach does not require a gastrointestinal model, which leads to a much simpler solution. Furthermore, this novel technique requires the identification of only one parameter of the minimal model because the rest of the model parameters are considered to have small variability. In order to account for such variability as well as to account for errors associated to measurements, interval analysis has been employed. Results: The current technique has been validated using data from a United States Food and Drug Administration-accepted type 1 diabetes simulator [root mean square error (RMSE) = 0.77] and successfully tested with two clinical data sets from the literature (RMSE = 0.69). Conclusions: The presented technique for the estimation of Ra showed excellent results when tested with simulated and actual clinical data. The simplicity of this new technique makes it suitable for large clinical research studies for the evaluation of the role of Ra in patients with impairments in glucose metabolism. In addition, this technique is being used to build a model library of mixed meals that could be incorporated into diabetic subject simulators in order to account for more realistic and varied meals. es_ES
dc.description.sponsorship This work has been funded by the Wellcome Trust, the Spanish Ministry of Science and Innovation through grant DPI2010-20764-C02, the European Union through FEDER funds, and Generalitat de Catalunya under Grant 2009 SGR 523. es_ES
dc.language Inglés es_ES
dc.publisher SAGE Publications es_ES
dc.relation.ispartof Journal of Diabetes Science and Technology es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Artificial pancreas es_ES
dc.subject Diabetes management es_ES
dc.subject Glucose rate of appearance es_ES
dc.subject Insulin sensitivity es_ES
dc.subject Robust estimation es_ES
dc.subject.classification INGENIERIA DE SISTEMAS Y AUTOMATICA es_ES
dc.title A simple robust method for estimating the glucose rate of appearance from mixed meals es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1177/193229681200600119 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Generalitat de Catalunya/Grups de Recerca Reconeguts per la Generalitat de Catalunya SGR 2009-2013/2009 SGR 523/ES/AEDS: AUTOMATION ENGINEERING AND DECISION SUPPORT SYSTEMS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GC//SGR 523/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//DPI2010-20764-C02-01/ES/NUEVAS ESTRATEGIAS DE CONTROL GLUCEMICO POSTPRANDIAL MEDIANTE TERAPIA CON BOMBA DE INSULINA EN DIABETES TIPO 1/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica es_ES
dc.description.bibliographicCitation Herrero, P.; Bondía Company, J.; Palerm, C.; Vehí, J.; Georgiou, P.; Oliver, N.; Toumazou, C. (2012). A simple robust method for estimating the glucose rate of appearance from mixed meals. Journal of Diabetes Science and Technology. 6(1):153-162. https://doi.org/10.1177/193229681200600119 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1177/193229681200600119 es_ES
dc.description.upvformatpinicio 153 es_ES
dc.description.upvformatpfin 162 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 6 es_ES
dc.description.issue 1 es_ES
dc.identifier.pmid 22401334 es_ES
dc.relation.pasarela S\240856 es_ES
dc.contributor.funder Generalitat de Catalunya es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)