Semi-empirical model of scroll compressors and its extension to describe vapor-injection compressors. Model description and experimental validation

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Semi-empirical model of scroll compressors and its extension to describe vapor-injection compressors. Model description and experimental validation

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Tello-Oquendo, Fernando es_ES
dc.contributor.author Navarro-Peris, Emilio es_ES
dc.contributor.author Barceló Ruescas, Francisco es_ES
dc.contributor.author Gonzálvez-Maciá, José es_ES
dc.date.accessioned 2020-04-29T07:04:43Z
dc.date.available 2020-04-29T07:04:43Z
dc.date.issued 2019-10 es_ES
dc.identifier.issn 0140-7007 es_ES
dc.identifier.uri http://hdl.handle.net/10251/141955
dc.description.abstract [EN] This paper presents a semi-empirical model of scroll compressors and proposes a methodology in order to extend this model to vapor-injection scroll compressors. The model takes into account the ideal evolution of the refrigerant throughout the compressor and considers the main sources of losses in the compression process. The model is able to predict the compressor and volumetric efficiencies in terms of ten empirical parameters, which have a direct physical interpretation. For the model validation, a series of four non-injected scroll compressors of different capacities were tested using R-290 and a scroll compressor with vapor-injection (SCVI) was characterized using R-407C. Results show a correct agreement between the experimental and calculated compressor efficiencies, with a maximum deviation of ±5%. Furthermore, the model estimates accurately the discharge temperature of the refrigerant, compressor power input, and refrigerant mass flow rate in the suction and injection port. Finally, the SCVI model response was evaluated by varying the intermediate pressure and the injection superheat. es_ES
dc.description.sponsorship Fernando M. Tello-Oquendo acknowledges the financial support provided by the CONVOCATORIA ABIERTA 2013-SEGUNDA FASE program, which was funded by the SENESCYT (Secretaría de Educación Superior, Ciencia, Tecnología e Innovación) (Grant No 2015-AR37665) of Ecuador. The authors would like to acknowledge the Spanish MINISTERIO DE ECONOMIA Y COMPETITIVIDAD , through the project ref-ENE2017-83665-C2-1-P Maximización de la eficiencia y minimización del impacto ambiental de bombas de calor para la descarbonización de la calefacción/ACS en los edificios de consumo casi nulo for the given support. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof International Journal of Refrigeration es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Scroll compressor es_ES
dc.subject Semi-empirical model es_ES
dc.subject Vapor-injection es_ES
dc.subject Experimental validation es_ES
dc.subject Compresseur à spirale es_ES
dc.subject Modèle semi-empirique es_ES
dc.subject Injection de vapeur es_ES
dc.subject Validation expérimentale es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.title Semi-empirical model of scroll compressors and its extension to describe vapor-injection compressors. Model description and experimental validation es_ES
dc.title.alternative Modélisation semi-empirique de compresseurs à spirale et ses extensions pour décrire les compresseurs à injection de vapeur. Description du modèle et la validation expérimentale es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.ijrefrig.2019.06.031 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/SENESCYT//2015-AR37665/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/ENE2017-83665-C2-1-P/ES/MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION%2FACS EN LOS EDIFICIOS DE CONSUMO CASI NULO/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada es_ES
dc.description.bibliographicCitation Tello-Oquendo, F.; Navarro-Peris, E.; Barceló Ruescas, F.; Gonzálvez-Maciá, J. (2019). Semi-empirical model of scroll compressors and its extension to describe vapor-injection compressors. Model description and experimental validation. International Journal of Refrigeration. 106:308-326. https://doi.org/10.1016/j.ijrefrig.2019.06.031 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.ijrefrig.2019.06.031 es_ES
dc.description.upvformatpinicio 308 es_ES
dc.description.upvformatpfin 326 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 106 es_ES
dc.relation.pasarela S\400886 es_ES
dc.contributor.funder Secretaría de Educación Superior, Ciencia, Tecnología e Innovación, Ecuador es_ES
dc.contributor.funder Agencia Estatal de Investigación es_ES
dc.subject.ods 07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem